Skip to content

ARROW IPN036836Recalls & reported problems

Teleflex Incorporated · Percutaneous Cavity Drainage Catheterization Seldinger Insertion Technique · Class 1

All models of ARROW (1488)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 50801902120156), received between Aug 10, 2021 and Aug 10, 2021 — classified as 1 malfunction.

The most frequently reported specific device problem is “Material Separation” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Apr 21, 2026Class IOpen, Classified

    Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.

    Z-2382-2026 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

Most reported problems

Device problems

  • Material Separation1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 10, 2021Material Separation; Material Separation

    COMPLAINT FOUND IN MAUDE DATABASE REPORTED AS:"PATIENT HAD A LEFT PERCUTANEOUS CHEST TUBE PLACED ON (B)(6) 2021 BY SELDINGER'S TECHNIQUE. IT HAS BEEN IN PLACE SINCE THAT TIME FUNCTIONAL. CXR ON (B)(6) 2021 NOTED A WORSENING PNEUMOTHORAX, BUT A WIRE DENSITY OBJECT WAS NOTED THAT DID NOT CORRELATE WITH A TELEMETRY WIRE. ULTIMATELY, THIS CHEST TUBE WAS EXCHANGED FOR A DIFFERENT TUBE, AND DURING THE EXCHANGE A PIECE OF THE GUIDEWIRE WAS IDENTIFIED AT THE END OF THE CATHETER WHILE IT WAS REMOVED. FDA SAFETY REPORT ID # (B)(4)."

    Patient problems: Insufficient Information

    MAUDE report 12300192 ↗

FDA clearance and classification

Cleared through 510(k) K895516 on Dec 27, 1989 (decision: Substantially Equivalent). Submitted by Arrow Intl., Inc. as “Cavity Drainage Catheterization Set, Cs-01600”. The FDA review took 106 days. FDA record ↗

The FDA regulates product code GBX (catheter, irrigation) under 21 CFR 878.4200 as a Class I device. 21 CFR 878.4200 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the ARROW IPN036836

Has the ARROW IPN036836 been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-2382-2026 (Class I), began on Apr 21, 2026: Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the ARROW IPN036836?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Aug 10, 2021. That report lists device problem “Material Separation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the ARROW IPN036836?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the ARROW IPN036836 FDA approved?

It was cleared through 510(k) K895516 on Dec 27, 1989. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the ARROW IPN036836, and is it still sold?

The FDA's device database lists Teleflex Incorporated as the company responsible for it (brand ARROW, model IPN036836). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other CATHETER, IRRIGATION devices

All CATHETER, IRRIGATION devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page