Skip to content

Shiley 18750Recalls & reported problems

Covidien LP · TaperGuard Oral/Nasal Tracheal Tube Murphy Eye · Class 2

All models of Shiley (387)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 60884522007530), received between Dec 18, 2018 and Mar 31, 2026 — classified as 2 injuries, 9 malfunctions.

The most frequently reported specific device problem is “Use of Device Problem” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Use of Device Problem7
  • Gas/Air Leak2
  • Component Missing1
  • Connection Problem1
  • Disconnection1
  • Inadequacy of Device Shape and/or Size1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8
  • Extubate2
  • No Consequences Or Impact To Patient1
  • Unintended Extubation1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 31, 2026Use of Device Problem

    IT WAS REPORTED THAT DURING PRE-USE TESTING OF THE ENDOTRACHEAL TUBE, THE CUFF WAS TESTED WITH A SYRINGE AND A CUFF PRESSURE GAUGE BUT THE CUFF DID NOT INFLATE OR DEFLATE AS EXPECTED. THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24737943 ↗
  • MalfunctionDec 11, 2025Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT THE CUFF OF THE ENDOTRACHEAL TUBE HAD INFLATION AND DEFLATION ISSUE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23785489 ↗
  • MalfunctionAug 8, 2025Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT DURING PRE-USAGE TESTING, THE ENDOTRACHEAL TUBE'S CUFF HAD LEAKED. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22751501 ↗
  • MalfunctionJul 5, 2024Use of Device Problem; Use of Device Problem

    ACCORDING TO THE REPORTER, POST-OPERATIVELY, THE PILOT LINE WAS OFF FROM THE ENDOTRACHEAL TUBE. THE REPLACEMENT OF THE TUBE WAS DONE.

    Patient problems: Unintended Extubation

    MAUDE report 19684204 ↗
  • MalfunctionMay 14, 2024Use of Device Problem; Use of Device Problem

    ACCORDING TO THE REPORTER, PRIOR USE, THE ENDOTRACHEAL TUBE'S CUFF HAD A LEAK DURING TESTING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19313282 ↗
  • MalfunctionSep 19, 2023Disconnection; Disconnection

    ACCORDING TO THE REPORTER, THE CONNECTOR TUBE WAS LOOSE AND EASILY DETACHES FROM THE ENDOTRACHEAL TUBE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17774510 ↗
  • MalfunctionMay 8, 2022Component Missing; Connection Problem; Component Missing; Connection Problem

    ACCORDING TO THE REPORTER, INTRA-OPERATIVELY, THE MATERIAL CAME WITHOUT THE TIP. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14332529 ↗
  • MalfunctionAug 18, 2021Use of Device Problem; Gas/Air Leak; Use of Device Problem; Gas/Air Leak

    ACCORDING TO THE REPORTER, WHEN THE CUFF WAS INFLATED, THE AIR LEAKED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12337783 ↗
  • MalfunctionOct 30, 2020Use of Device Problem; Gas/Air Leak; Use of Device Problem; Gas/Air Leak

    ACCORDING TO THE REPORTER, THE DEVICE CUFF HAD INFLATION AND DEFLATION ISSUE. THE CUFF LEAK WAS DETECTED BEFORE USE ON PATIENT. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient

    MAUDE report 10762499 ↗
  • InjuryApr 17, 2019Material Deformation; Material Deformation

    ACCORDING TO THE REPORTER, THE UNIT'S TUBE WAS BENT. THE PATIENT PRESENTED ALVEOLAR HYPOVENTILATION AND A REPLACEMENT OF THE TUBE HAS BEEN DONE TO GUARANTEE THE VENTILATION.

    Patient problems: Extubate

    MAUDE report 8523410 ↗
  • InjuryDec 18, 2018Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    ACCORDING TO THE REPORTER, THE TUBE PRESENTED FOLD IN THE FIRST MARKING THUS CREATING (MEMORY), MAKING IT DIFFICULT FOR THE PATIENT'S BREATHING. THE PATIENT WAS REINTUBATED.

    Patient problems: Extubate

    MAUDE report 8176102 ↗

Other Tube, tracheal (w/wo connector) devices

All Tube, tracheal (w/wo connector) devices →

Sources and updates