Skip to content

Hyflex 60018460Recalls & reported problems

Coltene/Whaledent Inc · Hyflex CM 31mm Assorted Pack · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI D661600184601), received between Jan 11, 2020 and Jan 11, 2020 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Code Available1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 11, 2020Break; Break

    DOCTOR WAS USING OUR HYFLEX CM FILES AND EXPERIENCE SEPARATION IN THE CANAL ON THE FIRST USE OF THE FILE. THE FILE HAD NOT BEEN USED PRIOR TO THIS CASE AND WAS BRAND NEW. DOCTOR COMPLAINS THAT UPON TORSIONAL LOAD OF LESS THAN 2.5NCM (HE HAD HIS TORQUE RATING PROPERLY SET) THE FILE SEPARATED AT THE STOP SECTION. IT DID NOT SEPARATE AT THE MANDREL BUT INSTEAD ABOUT 2MM DOWN FROM WHERE THE SPIRAL PART OF THE FILE BEGINS. IT WAS FILE 04/25 THAT BROKE FROM THE SET. THERE WAS NO PATIENT INJURY. THE CUSTOMER LATER INDICATED THAT THE EVENT HAPPENED DURING PROCEDURE AND HE HAD HAND FILED. HE SAID HE HAND FILES FOR EVERY CASE. THE DOCTOR INDICATED SIZE 15, BUT DID NOT RECALL IF HE USED OUR GLIDEPATH FILE. THE DOCTOR HAD TO BUY A THIRD PARTY INSTRUMENT IN ORDER TO REMOVE THE SEPARATED FILE.

    Patient problems: No Code Available

    MAUDE report 9579310 ↗

FDA clearance and classification

The FDA regulates product code EKS (file, pulp canal, endodontic) under 21 CFR 872.4565 as a Class I device. 21 CFR 872.4565 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Hyflex 60018460

Has the Hyflex 60018460 been recalled?

No FDA recall record in our data names this exact device identifier (DI D661600184601), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Hyflex 60018460?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jan 11, 2020. That report lists device problem “Break” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Hyflex 60018460?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Hyflex 60018460 FDA approved?

Devices of this type (product code EKS) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Coltene/Whaledent Inc.

Who makes the Hyflex 60018460, and is it still sold?

The FDA's device database lists Coltene/Whaledent Inc as the company responsible for it (brand Hyflex, model 60018460). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other File, Pulp Canal, Endodontic devices

All File, Pulp Canal, Endodontic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page