ProGlider PROGLIDE25DEMORecalls & reported problems
Tulsa Dental Products LLC · PROGLIDER Roatary Glide Path FILE STERILE 25MM US-Demo · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI D716PROGLIDE25DEMO1), received between Jul 21, 2025 and Sep 3, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Break3
Patient problems
- Device Embedded In Tissue or Plaque3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 3, 2025Break; Break
IN THIS EVENT IT IS REPORTED THAT A PROGLIDER 6FILE STERILE 25MM FILE BROKE DURING USE. THE BROKEN PART WAS NOT RETRIEVED AND IS STILL IN THE ROOT CANAL. NO INJURY.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 22950486 ↗MalfunctionJul 21, 2025Break; Break
IN THIS EVENT IT IS REPORTED THAT A PROGLIDER 3FILE STERILE 25MM BROKE DURING USE. THE BROKEN PART COULD NOT BE RETRIEVED AND THE PATIENT WAS REFERRED TO A SPECIALIST. NO INJURY.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 22553451 ↗MalfunctionJul 21, 2025Break; Break
IN THIS EVENT IT IS REPORTED THAT A PROGLIDER 3FILE STERILE 25MM BROKE DURING USE. THE BROKEN PART COULD NOT BE RETRIEVED. THE PATIENT WAS REFERRED TO AN ENDO SPECIALIST. NO INJURY.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 22553442 ↗
FDA clearance and classification
The FDA regulates product code EKS (file, pulp canal, endodontic) under 21 CFR 872.4565 as a Class I device. 21 CFR 872.4565 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the ProGlider PROGLIDE25DEMO
Has the ProGlider PROGLIDE25DEMO been recalled?
No FDA recall record in our data names this exact device identifier (DI D716PROGLIDE25DEMO1), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the ProGlider PROGLIDE25DEMO?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Jul 21, 2025 and Sep 3, 2025. In those reports, the most common specific device problem is “Break” (3); the most common patient problem is “Device Embedded In Tissue or Plaque” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the ProGlider PROGLIDE25DEMO?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the ProGlider PROGLIDE25DEMO FDA approved?
Devices of this type (product code EKS) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Tulsa Dental Products LLC.
Who makes the ProGlider PROGLIDE25DEMO, and is it still sold?
The FDA's device database lists Tulsa Dental Products LLC as the company responsible for it (brand ProGlider, model PROGLIDE25DEMO). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other FILE, PULP CANAL, ENDODONTIC devices
- WaveOne Gold Rotary File WGPRIME25Tulsa Dental Products LLC · FILE, PULP CANAL, ENDODONTIC68 reports
- EdgeTaper SETF225US Endodontics, LLC · FILE, PULP CANAL, ENDODONTIC1 recall1 report
- Edge File SX7400621RFUS Endodontics, LLC · FILE, PULP CANAL, ENDODONTIC1 recall0 reports
- Edge File SX7450421RFUS Endodontics, LLC · FILE, PULP CANAL, ENDODONTIC1 recall0 reports
- EdgeOne Fire SEOFAST31US Endodontics, LLC · FILE, PULP CANAL, ENDODONTIC1 recall0 reports
- EdgeSequel Sapphire SES150425US Endodontics, LLC · FILE, PULP CANAL, ENDODONTIC1 recall0 reports
- EdgeSequel Sapphire SES200421US Endodontics, LLC · FILE, PULP CANAL, ENDODONTIC1 recall0 reports
- EdgeSequel Sapphire SES300621US Endodontics, LLC · FILE, PULP CANAL, ENDODONTIC1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page