AngioDynamics 06597053Recalls & reported problems
Angiodynamics, Inc. · Stiffened Micro Introducer Kit · Class 2
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI H787065970530), received between Nov 13, 2019 and Apr 3, 2023 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Fracture” (2 reports).
9 other recalls cover devices cleared under the same FDA submission (K051655); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Fracture2
Patient problems
- Device Embedded In Tissue or Plaque1
- Foreign Body In Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 3, 2023Fracture; Fracture
AN END USER REPORTED AN ISSUE WITH A STF 5F M.I. KIT 45CM NT/T ECHO S KIT. A PATIENT PRESENTED FOR A DIAGNOSTIC HEART CATHETERIZATION FOR AN AORTIC VALVE SURGERY WORK UP. THE RIGHT HEART CATHETERIZATION AND CORONARY ANGIOGRAMS WERE COMPLETED. THE CARDIOLOGIST CROSSED THE AORTIC VALVE WITH STRAIGHT WIRE AND 5FR AL1 CATHETER, AND THEN EXCHANGED IT FOR A LANGSTON CATHETER. THE LEFT VENTRICLE AND AORTIC PRESSURES WERE OBTAINED, AT WHICH TIME THE WAVEFORMS APPEARED TO DAMPEN. THE TRANSDUCERS WERE TROUBLESHOOTED BY THE CARDIOLOGIST AND SCRUB TECH. A REPEAT NIBP CYCLED AND IT WAS NOTED TO BE LOWER THAN BASELINE. PRESSORS WERE STARTED AND AN ECHO WAS ORDERED. CT SURGERY WAS NOTIFIED AND THE PATIENT WAS PREPPED FOR PERICARDIOCENTESIS. WHILE GETTING ACCESS, THE MICROPUNCTURE WIRE BROKE OFF IN THE BODY. CT SURGERY WAS CONSULTED BY THE CARDIOLOGIST. PERICARIOCENTRESIS WAS DONE WITH 200CC SANGUINOUS OUTPUT. THE PATIENT WAS TAKEN TO CPU WITH CCU RN TO BE TAKEN FOR SURGERY WHEN CVOR WAS AVAILABLE.
Patient problems: Foreign Body In Patient
MAUDE report 16662526 ↗InjuryNov 13, 2019Fracture; Fracture
ON (B)(6) 2019, A PATIENT CAME IN FOR A NEURO INTERVENTION. WHILE ATTEMPTING TO GET VASCULAR ACCESS IN THE RIGHT GROIN, A PART OF THE WIRE BROKE OFF IN THE BODY. THE MD THEN WENT OVER TO THE LEFT GROIN, OBTAINED ACCESS AND CONTINUED WITH THE NEURO PROCEDURE. ONCE THE CASE WAS COMPLETED, A VASCULAR SURGEON SCRUBBED IN, OBTAINED ADDITIONAL IMAGING OF THE WIRE IN THE GROIN AND WAS ABLE TO REMOVE THE WIRE SHORTLY AFTER. THE REPORTED DEFECTIVE DISPOSABLE DEVICE HAS BEEN RETURNED TO THE MANUFACTURER FOR EVALUATION.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 9315232 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K051655. One submission often covers many models, so check the product and lot details in each record.
- Z-0418-2021 · Oct 14, 2020 · TerminatedAngiodynamics 5F Standard Micro-Introducer Kit - indicated for percutaneous introduction of a guidewire or catheter into the vascular system, Catalog Number: 06597035 UPN: H7870
- Z-0774-2017 · Sep 28, 2016 · TerminatedANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 4 F Stiffened Micro-Introducer Kit, 45CM NT/T ECHO B PG, Item Number H787065970505, Catalog No.REF 06597050
- Z-0775-2017 · Sep 28, 2016 · TerminatedANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 5 F Stiffened Micro-Introducer Kit, 45CM NT/T ECHO B PG, Item Number H787065970515, Catalog No.REF 06597051
- Z-0772-2017 · Sep 28, 2016 · TerminatedANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 5 F Stiffened Micro-Introducer Kit, 45CM SS/SS ECHO B PG, Item Number H787065970395, Catalog No.REF 0659703
- Z-0773-2017 · Sep 28, 2016 · TerminatedANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 4 F Stiffened Micro-Introducer Kit, 45CM SS/T ECHO B PG, Item Number H787065970465, Catalog No.REF 06597046
- Z-0776-2017 · Sep 28, 2016 · TerminatedANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 4 F Stiffened Micro-Introducer Kit, 45CM SS/T NON-ECHO S PG, Item Number H787065970655, Catalog No.REF 0659
- Z-0777-2017 · Sep 28, 2016 · TerminatedANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 5 F Stiffened Micro-Introducer Kit, 45CM NT/T NON-ECHO B PG, Item Number H787065970685, Catalog No.REF 0659
- Z-0778-2017 · Sep 28, 2016 · TerminatedANGIODYNAMICS 4F Stiffened Micro-Introducer, Item Number H787065971035, Catalog No.REF 06597103 Indicated for percutaneous introduction of guidewire or catheter into the vascular s
- Z-1405-2013 · Apr 30, 2013 · TerminatedAngioDynamics Micro Introducer Kits under the following labeling: 1) AngioDynamics 4F Standard Micro-Introducer Kit, Sterile, Catalog Number: 06597005, 2) AngioDynamics 5F Standar
Other CANNULA, CATHETER devices
- OptiSite Arterial Perfusion Cannula OPTI16Edwards Lifesciences LLC · CANNULA, CATHETER1 recall3 reports
- OptiSite Arterial Perfusion Cannula OPTI18Edwards Lifesciences LLC · CANNULA, CATHETER1 recall2 reports
- AngioDynamics 06597004Angiodynamics, Inc. · CANNULA, CATHETER4 reports
- AngioDynamics 06597015Angiodynamics, Inc. · CANNULA, CATHETER2 reports
- Arterial Cannula A212-65CSorin Group Italia Srl · CANNULA, CATHETER1 report
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.