Skip to content

Soft-Vu 10709402Recalls & reported problems

Angiodynamics, Inc. · Soft-Vu Angiographic Catheter, Renal, Braided · Class 2

All models of Soft-Vu (54)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI H787107094020), received between May 10, 2017 and May 10, 2017 — classified as 3 injuries.

The most frequently reported specific device problem is “Difficult to Advance” (3 reports).

23 other recalls cover devices cleared under the same FDA submission (K112452, K161596, K173762); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Difficult to Advance3
  • Entrapment of Device3

Patient problems

  • Aortic Dissection3
  • Patient Problem/Medical Problem3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 10, 2017Entrapment of Device; Difficult to Advance; Entrapment of Device; Difficult to Advance

    AS REPORTED TO ANGIODYNAMICS ON APRIL 10, 2017: THE TREATING PHYSICIAN REPORTED THAT DURING THE ANGIOGRAPHIC PROCEDURE, THE ANGIOGRAPHIC CATHETER SEEMED DIFFICULT TO MANIPULATE. WHILE ADVANCING THE CATHETER, THE TIP OF THE CATHETER CAUSED DISSECTION OF THE ARTERY WALL. IT WAS REPORTED THE DEFECTIVE DISPOSABLE DEVICE IS AVAILABLE FOR RETURN TO THE MANUFACTURER FOR EVALUATION.

    Patient problems: Aortic Dissection; Patient Problem/Medical Problem

    MAUDE report 6556398 ↗
  • InjuryMay 10, 2017Entrapment of Device; Difficult to Advance; Entrapment of Device; Difficult to Advance

    AS REPORTED TO ANGIODYNAMICS ON APRIL 10, 2017: THE TREATING PHYSICIAN REPORTED THAT DURING THE ANGIOGRAPHIC PROCEDURE, THE ANGIOGRAPHIC CATHETER SEEMED DIFFICULT TO MANIPULATE. WHILE ADVANCING THE CATHETER, THE TIP OF THE CATHETER CAUSED DISSECTION OF THE ARTERY WALL. IT WAS REPORTED THE DEFECTIVE DISPOSABLE DEVICE IS AVAILABLE FOR RETURN TO THE MANUFACTURER FOR EVALUATION.

    Patient problems: Aortic Dissection; Patient Problem/Medical Problem

    MAUDE report 6556397 ↗
  • InjuryMay 10, 2017Entrapment of Device; Difficult to Advance; Entrapment of Device; Difficult to Advance

    AS REPORTED TO ANGIODYNAMICS ON APRIL 10, 2017: THE TREATING PHYSICIAN REPORTED THAT DURING THE ANGIOGRAPHIC PROCEDURE, THE ANGIOGRAPHIC CATHETER SEEMED DIFFICULT TO MANIPULATE. WHILE ADVANCING THE CATHETER, THE TIP OF THE CATHETER CAUSED DISSECTION OF THE ARTERY WALL. IT WAS REPORTED THE DEFECTIVE DISPOSABLE DEVICE IS AVAILABLE FOR RETURN TO THE MANUFACTURER FOR EVALUATION.

    Patient problems: Aortic Dissection; Patient Problem/Medical Problem

    MAUDE report 6556396 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K112452, K161596, K173762. One submission often covers many models, so check the product and lot details in each record.

  • Z-1860-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Berenstein, Non-Braided; SOFT-VU BER 4F X 65CM 038 NB 0SH; Catalog No.: 10714009; Product/UPN No.: H787107140095 (Box), H787107140090 (Pouch); Box Qu
  • Z-1875-2026 · Mar 3, 2026 · Open, Classified
    AccuVu Angiographic Catheter, Pigtail, Non-Braided, With 21 R/O Markers; ACCU-VU PT 4F X 70CM 035 NB 10SH 21 R/O 1CM; Catalog No.: 13709804; Product/UPN No.: H787137098045 (Box), H
  • Z-1857-2026 · Mar 3, 2026 · Open, Classified
    Soft -Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 40CM 038 NB 0SH; Catalog No.: 10710013; Product/UPN No.: H787107100135 (Box), H787107100130 (Pouch); Box Quanti
  • Z-1863-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Berenstein, Non-Braided; SOFT-VU BER 4F X 100CM 038 NB 0SH; Catalog No.: 10714016; Product/UPN No.: H787107140165 (Box), H787107140160 (Pouch); Box Q
  • Z-1856-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Pigtail, Non-Braided; SOFT-VU PT 4F X 100CM 035 NB 10SH; Catalog No.: 10707103; Product/UPN No.: H787107071035 (Box), H787107071030 (Pouch); Box Quan
  • Z-1858-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Omni Flush, Non-Braided; SOFT-VU OF 4F X 65CM 038 NB 6SH; Catalog No.: 10714001; Product/UPN No.: H787107140015 (Box), H787107140010 (Pouch); Box Qua
  • Z-1867-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Sos Omni Selective (1), Non-Braided; SOFT-VU SO1 4F X 80CM 038 NB 0SH; Catalog No.: 10714024; Product/UPN No.: H787107140245 (Box), H787107140240 (Po
  • Z-1861-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Cobra (2), Non-Braided; SOFT-VU CB2 4F X 65CM 038 NB 0SH; Catalog No.: 10714011; Product/UPN No.: H787107140115 (Box), H787107140110 (Pouch); Box Qua
  • Z-1864-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Cobra (1), Non-Braided; SOFT-VU CB1 4F X 100CM 038 NB 0SH; Catalog No.: 10714017; Product/UPN No.: H787107140175 (Box), H787107140170 (Pouch); Box Qu
  • Z-1865-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Cobra (2), Non-Braided; SOFT-VU CB2 4F X 100CM 038 NB 0SH; Catalog No.: 10714018; Product/UPN No.: H787107140185 (Box), H787107140180 (Pouch); Box Qu
  • Z-1868-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Headhunter (1), Non-Braided; SOFT-VU HH1 4F X 100CM 038 NB 0SH; Catalog No.: 10714040; Product/UPN No.: H787107140405 (Box), H787107140400 (Pouch); B
  • Z-1859-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Pigtail, Non-Braided; SOFT-VU PT 4F X 65CM 038 NB 10SH; Catalog No.: 10714002; Product/UPN No.: H787107140025 (Box), H787107140020 (Pouch); Box Quant
  • Z-1874-2026 · Mar 3, 2026 · Open, Classified
    AccuVu Angiographic Catheter, Omni Flush, Non-Braided, With 21 R/O Markers; ACCU-VU OF 4F X 70CM 035 NB 6SH 21 R/O 1CM; Catalog No.: 13709704; Product/UPN No.: H787137097045 (Box),
  • Z-1873-2026 · Mar 3, 2026 · Open, Classified
    AccuVu Angiographic Catheter, Straight Flush, Non-Braided, With 10 R/O Markers; ACCU-VU STR FL 4F X 100CM 035 NB 6SH 10 R/O 6@1CM 4@5CM; Catalog No.: 13709604; Product/UPN No.: H78
  • Z-1862-2026 · Mar 3, 2026 · Open, Classified
    Soft-Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 65CM 038 NB 0SH; Catalog No.: 10714014; Product/UPN No.: H787107140145 (Box), H787107140140 (Pouch); Box Quantit

…and 8 more.

Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices

All CATHETER, INTRAVASCULAR, DIAGNOSTIC devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page