Skip to content

Total Abscession 14000823Recalls & reported problems

Angiodynamics, Inc. · 8F x 30cm Total Abscession General Drainage Catheter (Locking Pigtail) · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI H787140008230), received between Mar 18, 2025 and Mar 18, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 18, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    AN END USER REPORTED AN ISSUE WITH A TOTAL ABSCESSION DRAINAGE CATHETER GEN 8F X 30CM WITHOUT R/O BAND.THE CATHETER WAS USED DURING A CT-GUIDED CYST DRAINAGE AND SCLEROTHERAPY. WHEN THE CATHETER WAS BEING REMOVED FROM PATIENT, THE TECH NOTED THAT THE TIP OF THE CATHETER WAS MISSING. A CT OF PELVIS CONFIRMED PRESENCE OF RETAINED TIP IN THE ENDOMETRIOMA. THERE WAS AN ATTEMPT TO REMOVE THE TIP WITH A PERCUTANEOUS PROCEDURE, BUT WAS UNSUCCESSFUL DUE TO IT BEING EMBEDDED IN THE TISSUE.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 21631464 ↗

Other CATHETER, IRRIGATION devices

All CATHETER, IRRIGATION devices →

Sources and updates