BioFlo 60M701101Recalls & reported problems

Navilyst Medical, Inc. · PICC Convenience Kit · Class 2 · Implant

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI H96560M7011010), received between Dec 19, 2025 and Dec 19, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 19, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    A SPECTRUM DISTRIBUTOR REPORTED AN END USER EXPERIENCED AN ISSUE WHEN USING A CAN 4F SL BIOFLO PASV PICC - NURSING TRAY, CALGARY REGIONAL HEALTH AUTHORITY. PRIOR TO INSERTION, THE PICC WAS NOT WIPED WITH ANY CLEANING SOLUTION AND THE MARKERS WERE VISIBLE AFTER TWO HOURS OF BEING PLACED. THE PATIENT HAD THE PICC INSERTED HOWEVER, THE TIP WAS MALPOSITIONED IN HER RIGHT INTERNAL JUGULAR (IJ). THE PICC WAS LEFT OVER THE WEEKEND TO SEE IF IT WOULD DESCEND INTO THE SUPERIOR VENA CAVA (SVC). WHEN SHE WAS REASSESSED, IT WAS OBSERVED THAT THE CM MARKING NOTCHES AND EVERY 5CM NUMBER INDICATORS COULD NOT BE SEEN PAST THE 4CM MARK. THE PLAN WAS MADE TO EXCHANGE THE PICC TO A MIDLINE. WHEN THE PICC WAS REMOVED, IT WAS NOTED THAT MANY OF THE CM MARKINGS WERE DIFFICULT TO SEE AND THE WRITTEN NUMBER AT EVERY 5CM WAS "ERASED" AND UNABLE TO BE SEEN. IT WAS REPORTED THAT THE "MISSING" MARKERS WERE LOCATED OUTSIDE OF THE PATIENT'S SKIN AND WITHIN THE BLOOD STREAM.

    Patient problems: Foreign Body In Patient

    MAUDE report 23851355 ↗

Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices

All Catheter,intravascular,therapeutic,long-term greater than 30 days devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.