Skip to content

iTotal® Cruciate Retaining (CR) Knee Replacement System TCR111111102Recalls & reported problems

Conformis, Inc. · N/A · Class 2

All models of iTotal Cruciate Retaining (CR) Knee Replacement System (4)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Conformis iTotal CR knee replacement has 390 reports in the FDA database, 371 of them describing injuries and no deaths. Many reports describe patients needing another surgery because of looseness, instability, sinking of the tibia, or limited range of motion. Reports also mention infection. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
390
Deaths reported
0
Injuries reported
371
Recalls naming it
0

Summary

The FDA's MAUDE database contains 390 adverse event reports that list this exact device (DI M572TCR1111111021), received between Mar 24, 2016 and Apr 30, 2025 — classified as 371 injuries, 19 malfunctions.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (72 reports).

7 other recalls cover devices cleared under the same FDA submission (K140423, K142161); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem99
  • Appropriate Device Problem Term/Code Not Available80
  • Loose or Intermittent Connection72
  • Insufficient Device Problem Information48
  • Loosening of Implant Not Related to Bone-Ingrowth28
  • Unstable20
  • Device Slipped8
  • Device Markings/Labelling Problem6

Patient problems

  • Unspecified Infection98
  • No Code Available63
  • No Known Impact Or Consequence To Patient53
  • Insufficient Information44
  • No Information29
  • Failure of Implant23
  • Loss of Range of Motion23
  • Pain21

Recent adverse event reports

The 25 most recent of 390 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 30, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED PAIN IN THE AFFECTED KNEE FOLLOWING TOTAL KNEE REPLACEMENT SURGERY. APPROXIMATELY 42 MONTHS FOLLOWING INITIAL SURGERY, THE PATIENT UNDERWENT REVISION SURGERY ON THE SAME KNEE.

    Patient problems: Ambulation or Postural Difficulties; Limb Pain

    MAUDE report 21938299 ↗
  • InjuryDec 13, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS TIBIAL SUBSIDENCE. PRIMARY SURGERY OCCURRED ON (B)(6) 2017. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 15973110 ↗
  • InjuryNov 11, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2020. REVISION SURGERY IS PLANNED FOR ON (B)(6) 2022.

    Patient problems: Joint Laxity

    MAUDE report 15784226 ↗
  • InjuryOct 27, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2018. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Joint Laxity

    MAUDE report 15685257 ↗
  • InjuryOct 5, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2020. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Joint Laxity

    MAUDE report 15544088 ↗
  • InjurySep 9, 2022Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS INSTABILITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2019. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 15396845 ↗
  • InjuryJun 24, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS PATELLA RESURFACING. PRIMARY SURGERY OCCURRED ON (B)(6) 2016. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 14806440 ↗
  • InjuryJun 23, 2022Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS DUE TO LIMITED RANGE OF MOTION. PRIMARY SURGERY OCCURRED ON (B)(6) 2020. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Loss of Range of Motion

    MAUDE report 14794020 ↗
  • InjuryJun 15, 2022Unstable

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS MID FLEXION INSTABILITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2016. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Joint Laxity

    MAUDE report 14705083 ↗
  • InjuryJun 12, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2021. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 14672623 ↗
  • InjuryJun 10, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS (10MM-12MM, E-G) HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2016. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Joint Laxity

    MAUDE report 14657540 ↗
  • InjuryJun 5, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS PATELLA RESURFACING. PRIMARY SURGERY OCCURRED ON (B)(6)2016. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 14599716 ↗
  • InjuryJun 1, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY, WITH THE SUSPECTED CAUSE BEING THE PATIENT'S HIGH BMI OF 46. PRIMARY SURGERY OCCURRED ON (B)(6) 2015. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 14570561 ↗
  • InjuryMay 28, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LIMITED RANGE OF MOTION. PRIMARY SURGERY OCCURRED ON (B)(6) 2016. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Loss of Range of Motion

    MAUDE report 14538665 ↗
  • InjuryMay 11, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS AND TIBIAL TRAY HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS TIBIAL LOOSENING. PRIMARY SURGERY OCCURRED ON (B)(6) 2017. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 14366607 ↗
  • InjuryMay 8, 2022Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2017. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 14332548 ↗
  • InjuryMay 6, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS DUE TO THE PATIENT EXPERIENCING A QUADRICEPS TEAR, AND THE POLY INSERTS WILL BE EXCHANGED DURING THE PROCEDURE. PRIMARY SURGERY OCCURRED ON (B)(6) 2021. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Muscle/Tendon Damage

    MAUDE report 14311622 ↗
  • InjuryApr 22, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS (8MM, 10MM, 12MM, 14MM, C, E, G, J) AND TIBIAL TRAY IMPLANT HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS TIBIAL IMPLANT LOOSENING OF UNKNOWN CAUSE. PRIMARY SURGERY OCCURRED ON (B)(6) 2017. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 14181058 ↗
  • InjuryApr 3, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS INFECTION. PRIMARY SURGERY OCCURRED ON (B)(6) 2018. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Unspecified Infection

    MAUDE report 13992685 ↗
  • InjuryMar 31, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS DUE TO THE IMPLANT BEING LOOSE AND THE PATELLA IMPLANT HAD COME OFF COMPLETELY. PRIMARY SURGERY OCCURRED ON (B)(6) 2017. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 13971443 ↗
  • InjuryMar 31, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS PATELLA RESURFACING DUE TO THE PATIENT HAVING ANTERIOR KNEE PAIN IN EXTENSION AND DEEP FLEXION. PRIMARY SURGERY OCCURRED ON (B)(6) 2018. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Pain

    MAUDE report 13971315 ↗
  • InjuryMar 9, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS (8MM, 10MM, 12MM, B, D, F) HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2018. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 13714984 ↗
  • InjuryMar 2, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2019. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 13656854 ↗
  • InjuryFeb 27, 2022Loose or Intermittent Connection; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS LAXITY. PRIMARY SURGERY OCCURRED ON (B)(6) 2018. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Insufficient Information

    MAUDE report 13615726 ↗
  • InjuryFeb 2, 2022Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT REPLACEMENT POLY INSERTS HAVE BEEN REQUESTED FOR REVISION SURGERY. REASON FOR REVISION IS A SUSPECTED INFECTION. PRIMARY SURGERY OCCURRED ON (B)(6) 2016. REVISION SURGERY IS PLANNED FOR (B)(6) 2022.

    Patient problems: Unspecified Infection

    MAUDE report 13429611 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K140423, K142161. One submission often covers many models, so check the product and lot details in each record.

  • Z-1070-2016 · Jan 28, 2016 · Terminated
    Conformis iTotal Cruciate Retaining (CR) Knee Replacement System Model: TCR-111-1111
  • Z-0145-2016 · Aug 31, 2015 · Terminated
    ConForMIS iTotal CR (Cruciate Retaining) Knee Replacement System-iTOTAL CR, Left Knee Catalog Number: M57250600010 (US) M5725INT0600010 (OUS)
  • Z-0141-2016 · Aug 31, 2015 · Terminated
    ConForMIS iUni Unicondylar Knee Replacement System- iUNI G2, Right Medial Catalog Number:M57220600220 (US) M5722INT0600220 (OUS)
  • Z-0146-2016 · Aug 31, 2015 · Terminated
    ConFormis iTotal CR Knee Replacement System- iTOTAL CR, Right Knee Catalog Number: M57250600020 (US) M5725INT0600020 (OUS)
  • Z-0147-2016 · Aug 31, 2015 · Terminated
    ConFormis iTotal Posterior Stabilized Knee Replacement System- ITOTAL PS-IPOLY- IMPLANT KIT-LEFT and ITOTAL PS-IPOLY-IMPLANT KIT-RIGHT Catalog Number:TPS1111111
  • Z-0144-2016 · Aug 31, 2015 · Terminated
    ConFormis iTotal CR Knee Replacement System- ITOTAL CR - IPOLY - IMPLANT KIT UNCAPTURED - LEFT ITOTAL CR - IPOLY - IMPLANT KIT UNCAPTURED - RIGHT Catalog Number: TCR1111111
  • Z-0581-2015 · Nov 19, 2014 · Terminated
    Conformis iTotal CR G2 Knee Replacement System Catalog/Model #: M57250600010 Intended for use as a total knee replacement in patients with knee joint pain and disability.

Other Knee Arthroplasty Implantation System devices