Skip to content

CONSERVE® 38015035Recalls & reported problems

Microport Orthopedics Inc. · CONSERVE® BFH® HEAD 50MM LONG NECK · Class 3 · Implant

All models of CONSERVE (74)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M684380150351), received between Aug 4, 2023 and Aug 4, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Insufficient Device Problem Information1

Patient problems

  • Metal Related Pathology1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 4, 2023Insufficient Device Problem Information; Insufficient Device Problem Information

    ALLEGEDLY, ON (B)(6) 2023 WE RECEIVE A COMPLAINT NOTIFICATION FROM AOU PISANA ON THR WITH CONSERVE. FIRST SURGERY DONE IN 2006 IN A DIFFERENT HOSPITAL AND FOR THIS REASON IT'S IMPOSSIBLE TO RETRIEVE MORE INFO AND DETAILS. IN THE EXAMINATION THE PATIENT WAS DIAGNOSED WITH A METALLOSIS WHICH MADE NECESSARY TO REMOVE CUP, HEAD, STEM AND MODULAR NECK. UNFORTUNATELY, NO INFO AVAILABLE ON STEM AND NECK.

    Patient problems: Metal Related Pathology

    MAUDE report 17461372 ↗

FDA clearance and classification

The FDA regulates product code KWA (prosthesis, hip, semi-constrained (metal uncemented acetabular component)) under 21 CFR 888.3330 as a Class III device. 21 CFR 888.3330 ↗

Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the CONSERVE® 38015035

Has the CONSERVE® 38015035 been recalled?

No FDA recall record in our data names this exact device identifier (DI M684380150351), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the CONSERVE® 38015035?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Aug 4, 2023. That report lists patient problem “Metal Related Pathology” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the CONSERVE® 38015035?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the CONSERVE® 38015035 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the CONSERVE® 38015035, and is it still sold?

The FDA's device database lists Microport Orthopedics Inc. as the company responsible for it (brand CONSERVE®, model 38015035). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component) devices

All Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page