CONSERVE® 38AC4400Recalls & reported problems
Microport Orthopedics Inc. · CONSERVE® TOTAL A-CLASS® 44MM FEMORAL HEAD · Class 3 · Implant
All models of CONSERVE (74)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI M68438AC44001), received between Jun 5, 2019 and Jun 2, 2023 — classified as 3 injuries.
The most frequently reported specific device problem is “Corroded” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Corroded1
- Material Disintegration1
- Mechanical Problem1
Patient problems
- Pain2
- Metal Related Pathology1
- Reaction1
- Tissue Damage1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJun 2, 2023Corroded; Corroded
ALLEGEDLY, 80% TEAR OF GLUTEUS MEDIUS WITH FIBERS REMAINING OVER ANTERIOR EDGE OF GREATER TROCHANTER, BALD REMAINDER OF GREATER TROCHANTER. TRUNNIOSIS WITH BURNISHING OF THE FEMORAL SHORT NECK TRUNNION AT BOTH THE HEAD AND PROXIMAL BODY INTERFACES. STABLE ACETABULAR, FEMORAL COMPONENTS. YELLOW CLEAR SEROUS JOINT FLUID, SENT FOR CELL COUNT, CULTURE. PSEUDOTUMOR OVER GREATER TROCHANTER SENT TO PATHOLOGY. PAIN, CORROSION AND SUSPECTED METALLOSIS. NON REVISED PRODUCTS: PRODUCT ID: SPHS8000 PROFEMUR® R 135MM.STEM SIZE 10 MTS.FINISH STRAIGHT/TAPER/ LOT NO.: 07493194/ QTY: 1.
Patient problems: Metal Related Pathology; Pain
MAUDE report 17049526 ↗InjuryDec 30, 2020Mechanical Problem; Mechanical Problem
ALLEGEDLY, THE NECK SLEEVE AND HEAD CAME OUT AS ONE DURING EXPLANT SURGERY AND NECK TRUNNION WAS BLACK. LEFT HIP. HEAD AND NECKS WERE REPLACED. COMPONENTS NOT REVISED: CONSERVE® PLUS CUP PRODUCT NUMBER 38024450 LOT NUMBER 029783710. PROFEMUR® PLASMA Z STEM PRODUCT NUMBER PHA00262 LOT NUMBER 049943762.
Patient problems: Tissue Damage
MAUDE report 11095357 ↗InjuryJun 5, 2019Material Disintegration; Material Disintegration
ALLEGEDLY THE PATIENT WAS REVISED DUE TO MOM COMPLICATIONS: PAIN; HIGH COCR LEVELS. (RIGHT). HEAD, SLEEVE AND NECK WERE EXPLANTED. STRYKER DUAL MOBILITY WAS USED WITH OUR LONG 28MM CERAMIC HEAD AND A SHORT MODULAR NECK (VV8) WAS IMPLANTED.
Patient problems: Pain; Reaction
MAUDE report 8670673 ↗
FDA clearance and classification
The FDA regulates product code JDL (prosthesis, hip, semi-constrained (metal cemented acetabular component)) under 21 CFR 888.3320 as a Class III device. 21 CFR 888.3320 ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CONSERVE® 38AC4400
Has the CONSERVE® 38AC4400 been recalled?
No FDA recall record in our data names this exact device identifier (DI M68438AC44001), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CONSERVE® 38AC4400?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Jun 5, 2019 and Jun 2, 2023. In those reports, the most common specific device problems are “Corroded” (1), “Material Disintegration” (1) and “Mechanical Problem” (1); the most common patient problems are “Pain” (2), “Metal Related Pathology” (1) and “Reaction” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CONSERVE® 38AC4400?
None of the reports are classified as deaths, 3 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CONSERVE® 38AC4400 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the CONSERVE® 38AC4400, and is it still sold?
The FDA's device database lists Microport Orthopedics Inc. as the company responsible for it (brand CONSERVE®, model 38AC4400). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component) devices
- Omnifit 2001-2246Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained (metal cemented acetabular component)1 recall0 reports
- Taperloc Complete Micro Primary Femoral 51-107150Biomet Orthopedics, LLC · Prosthesis, hip, semi-constrained (metal cemented acetabular component)40 reports
- Taperloc Complete Micro Primary Femoral 51-107140Biomet Orthopedics, LLC · Prosthesis, hip, semi-constrained (metal cemented acetabular component)36 reports
- Dynasty DSBFGD52Microport Orthopedics Inc. · Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)12 reports
- CONSERVE® 38AM4600Microport Orthopedics Inc. · Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)8 reports
- CONSERVE® 38AM4804Microport Orthopedics Inc. · Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)7 reports
- CONSERVE® 38AM4404Microport Orthopedics Inc. · Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)6 reports
- TRANSCEND® 26000025Microport Orthopedics Inc. · Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)5 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page