AMD-RITMEDRecalls & reported problems across all models
AMD Medicom Inc · 3 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
2 open recalls name at least one AMD-RITMED model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls
- 2
We found 3 models of AMD-RITMED by AMD Medicom Inc in the FDA's device registry (GUDID). Together they are named in 1 adverse event report in the FDA's MAUDE database, received between Oct 20, 2020 and Oct 20, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Integrity Problem” (1 report).
2 FDA recall records name at least one of these models by its device identifier, 2 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
AMD-RITMED recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- May 8, 2026Open, Classified
Neurological sponges used to moisten or absorb biological fluid during neurological surgery and may also be used to protect the brain during incision, may not consistently meet endotoxin specification for devices that contact the cerebrospinal fluid. Elevated endotoxin levels may lead to neurovascular adverse events, febrile response, and/or local transient inflammation, hypotension, or nausea.
Z-2459-2026 · Root cause: Material/Component Contamination · Recall details · FDA record ↗
- May 8, 2026Open, Classified
Neurological sponges used to moisten or absorb biological fluid during neurological surgery and may also be used to protect the brain during incision, may not consistently meet endotoxin specification for devices that contact the cerebrospinal fluid. Elevated endotoxin levels may lead to neurovascular adverse events, febrile response, and/or local transient inflammation, hypotension, or nausea.
Z-2458-2026 · Root cause: Material/Component Contamination · Recall details · FDA record ↗
Most reported AMD-RITMED problems
Device problems
- Material Integrity Problem1
Patient problems
- No Consequences Or Impact To Patient1
AMD-RITMED models
3 models, most reported first. Each model has its own page with its reports, recalls and device details.
- AMD-RITMED 85995CGAUZE/SPONGE, INTERNAL, X-RAY DETECTABLE1 recall0 reports
- AMD-RITMED 55992CGAUZE/SPONGE, INTERNAL, X-RAY DETECTABLE1 recall0 reports
- AMD-RITMED 1501-ROLLGAUZE/SPONGE, INTERNAL, X-RAY DETECTABLE1 report
Recent AMD-RITMED adverse event reports
The 1 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2020Material Integrity Problem; Material Integrity Problem
A PRODUCT COMPLAINT WAS REPORTED TO AMD MEDICOM ON 28-AUG-2020 FOR AMD-RITMED LAPAROTOMY SPONGE ITEM CODE 1501-ROLL LOT# 81043-1. THE LAPAROTOMY SPONGE IS CLASSIFIED AS A CLASS 1 MEDICAL DEVICE UNDER FDA CODE GDY. THE FOLLOWING INFORMATION WAS INITIALLY REPORTED "LINT ON OVERHEAD TABLE COVER AND INSTRUMENTS. LINT ON LIVER DURING PROCEDURE" THE COMPLAINT RECEIVED BY AMD MEDICOM HAS BEEN LOGGED AS A PRODUCT QUALITY COMPLAINT UNDER (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10706696 ↗
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page