Arterial Line KitRecalls & reported problems across all models
Argon Medical Devices, Inc. · 2 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names at least one Arterial Line Kit model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls
- 1
We found 2 models of Arterial Line Kit by Argon Medical Devices, Inc. in the FDA's device registry (GUDID). Together they are named in 2 adverse event reports in the FDA's MAUDE database, received between Mar 21, 2022 and Apr 19, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
1 FDA recall record name at least one of these models by its device identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Arterial Line Kit recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Jun 1, 2026Open, Classified
Kits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility.
Z-2708-2026 · Root cause: Material/Component Contamination · Recall details · FDA record ↗
Most reported Arterial Line Kit problems
Device problems
- Break2
- Entrapment of Device1
- Nonstandard Device1
- Patient Device Interaction Problem1
Patient problems
- Foreign Body In Patient2
- Hemorrhage/Blood Loss/Bleeding1
Arterial Line Kit models
2 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Arterial Line Kit 400115AGauze/Sponge, Internal, X-Ray Detectable1 recall0 reports
- Arterial Line Kit 498411BGauze/Sponge, Internal, X-Ray Detectable2 reports
Recent Arterial Line Kit adverse event reports
The 2 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionApr 19, 2022Break; Entrapment of Device; Patient Device Interaction Problem
THE ARTERIAL LINE WAS PLACED ON THE . THE PATIENTS ARTERIAL LINE DRESSING WAS CHANGED PER HOSPITAL PROTOCOL AFTER REMOVING THE PREVIOUS DRESSING . ANEW DRESSING WAS APPLIED THE ARTERIAL LINE WAS FUNCTIONING PROPERLY FOR A FEW MINUTES AFTER THE DRESSING CHANGE AS THE ARTERIAL LINE TUBING WAS BEING SECURED. THE PATENT BENT HER WRIST AND THE ARTERIAL LINE WAS INADVERTENTLY REMOVED IN THE PROCESS AFTER THE BLEEDING WAS MANAGED. THE DRESSING WAS REMOVED AND IMMEDIATELY IT WAS RECOGNIZED THAT THE MAJORITY OF THE ARTERIAL LINE CATHETER BAD BROKEN OFF AND REMAINED IN THE PATENTS ARTERY. THE PATIENT WAS SUBSEQUENTLY TAKEN TO THE OPERATING ROOM FOR REMOVAL OF THE RETAINED PORTION OF THE ARTERIAL CATHETER, THE INCLUDED MANUFACTURING INFO (SERIAL LOT NUMBER) WAS RETRIEVED FROM AN ARTERIAL LINE KIT ON THE DAY OF THE EVENT. UNSURE IF IT IS THE SPECIFIC INFORMATION FOR THE DEVICE RELATED TO THIS REPORT OF NOTE PREVIOUS REPORT WITH A SIMILAR ISSUE WAS REPORTED FOR THIS PRODUCT TO THE FDA 2/2019.
Patient problems: Foreign Body In Patient; Hemorrhage/Blood Loss/Bleeding
MAUDE report 14139640 ↗MalfunctionMar 21, 2022Break; Nonstandard Device
ARTERIAL LINE WAS PLACED ON (B)(6) 2022 THE ARTERIAL PATIENTS LINE DRESSING WAS CHANGED PER PROTOCOL. AFTER REMOVING THE PERVIOUS DRESSING, A STRONG ARTERIAL LINE READING WAS NOTED ON THE MONITOR AND A NEW WAS APPLIED. THE ARTERIAL LINE WAS FUNCTIONING PROPERLY FOR A FEW MINUTES AFTER THE DRESSING CHANGE AS THE ARTERIAL LINE TUBING WAS REMOVED AND IMMEDIATELY IT WAS RECOGNIZED THAT THE MAJORITY OF THE ARTERIAL LINE CATHETER HAD BROKEN ON AND REMAINED IN THE PATIENT ARTERY. THE PATIENT WAS SUBSEQUENTLY TAKEN TO THE OR FOR REMOVED TO THE RETAINED PORTION OF THE ARTERIAL CATHETER.
Patient problems: Foreign Body In Patient
MAUDE report 13839834 ↗
Other Argon Medical Devices, Inc. products
- First PICC S/L Peripherally Inserted Central Catheter5 models · 174 reports
- BioPince Ultra Full Core Biopsy Instrument10 models · 85 reports · 1 recall
- BioPince Full Core Biopsy Instrument5 models · 60 reports · 1 recall
- L-Cath PICC S/L2 models · 30 reports · 1 recall
- Tru-Core II Biopsy Instrument8 models · 13 reports · 1 recall
- Scorpion2 models · 7 reports · 1 recall
- Tru-Core II URO Biopsy Instrument2 models · 2 reports · 1 recall
- Transvenous Pacing Electrode Tray2 models · 0 reports · 1 recall
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page