Skip to content

Artix MTRecalls & reported problems across all models

Inari Medical, Inc. · 2 models in the FDA device registry

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names at least one Artix MT model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.

Adverse event reports
11
Deaths reported
0
Injuries reported
10
Recalls
1

We found 2 models of Artix MT by Inari Medical, Inc. in the FDA's device registry (GUDID). Together they are named in 11 adverse event reports in the FDA's MAUDE database, received between Apr 2, 2025 and May 26, 2026 — classified as 10 injuries, 1 malfunction.

The most frequently reported specific device problem is “Entrapment of Device” (4 reports).

1 FDA recall record name at least one of these models by its device identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 2 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Artix MT recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Apr 8, 2025Open, Classified

    Thrombectomy device specifies vessel range of 2.5-6 mm on the pouch, carton, and Instructions for Use rather than the correct vessel range of 3-6 mm, which could incrementally increase the radial force on the artery, which has the potential of vascular complications.

    Z-1728-2025 · Root cause: Labeling Change Control · Recall details · FDA record ↗

Most reported Artix MT problems

Device problems

  • Entrapment of Device4
  • Migration3
  • Detachment of Device or Device Component2
  • Adverse Event Without Identified Device or Use Problem1
  • Material Separation1
  • Migration or Expulsion of Device1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Vascular Dissection3
  • Device Embedded In Tissue or Plaque2
  • Obstruction/Occlusion2
  • Great Vessel Perforation1
  • Insufficient Information1

Artix MT models

2 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent Artix MT adverse event reports

The 11 most recent reports across all models, in the reporter's own words as published by the FDA.

Other Inari Medical, Inc. products

All Inari Medical, Inc. devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page