AvenirRecalls & reported problems across all models
Zimmer GmbH · 24 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 57
- Deaths reported
- 0
- Injuries reported
- 49
- Recalls
- 1
We found 24 models of Avenir by Zimmer GmbH in the FDA's device registry (GUDID). Together they are named in 57 adverse event reports in the FDA's MAUDE database, received between Nov 7, 2018 and Apr 28, 2026 — classified as 49 injuries, 8 malfunctions.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (11 reports).
1 FDA recall record name at least one of these models by its device identifier.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Avenir recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Oct 31, 2018Terminated
Mislabeled Labeled Avenir Mller Stem size 1, the stem inside the packaging is an Avenir Mller Stem size 2 .
Z-0644-2019 · Root cause: Process control · Recall details · FDA record ↗
Most reported Avenir problems
Device problems
- Adverse Event Without Identified Device or Use Problem14
- Patient Device Interaction Problem11
- Fracture9
- Insufficient Device Problem Information8
- Appropriate Device Problem Term/Code Not Available3
- Activation, Positioning or Separation Problem2
- Device Markings/Labelling Problem2
- Inadequacy of Device Shape and/or Size2
Patient problems
- Bone Fracture(s)23
- Fall12
- Pain9
- Failure of Implant7
- Insufficient Information3
- No Clinical Signs, Symptoms or Conditions3
- No Information3
- Debris, Bone Shedding2
Avenir models
24 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Avenir® 01.06010.001Prosthesis, hip, semi-constrained, metal/polymer, uncemented1 recall4 reports
- Avenir® 01.06010.003Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented5 reports
- Avenir® 01.06010.004Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented5 reports
- Avenir® 01.06010.105Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented5 reports
- Avenir® 01.06010.002Prosthesis, hip, semi-constrained, metal/polymer, uncemented4 reports
- Avenir® 01.06010.004Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate3 reports
- Avenir® 01.06010.005Prosthesis, hip, constrained, cemented or uncemented, metal/polymer3 reports
- Avenir® 01.06010.107Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented3 reports
- Avenir® 01.06010.003Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate2 reports
- Avenir® 01.06010.105Prosthesis, hip, constrained, cemented or uncemented, metal/polymer2 reports
- Avenir® 01.06010.107Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented2 reports
- Avenir® 01.06010.007Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented2 reports
- Avenir® 01.06010.001Prosthesis, hip, semi-constrained, uncemented, metal / polymer, non-porous, calcium phosphate2 reports
- Avenir® 01.06010.103Prosthesis, hip, semi-constrained, uncemented, metal / polymer, non-porous, calcium phosphate2 reports
- Avenir® 01.06010.104Prosthesis, hip, semi-constrained, metal/polymer, uncemented2 reports
- Avenir® 01.06010.005Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented2 reports
- Avenir® 01.06010.008Prosthesis, hip, constrained, cemented or uncemented, metal/polymer2 reports
- Avenir® 01.06620.004Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 report
- Avenir® 01.06010.002Prosthesis, hip, semi-constrained, metal/polymer, uncemented1 report
- Avenir® 01.06010.301Prosthesis, hip, semi-constrained, metal/polymer, uncemented1 report
- Avenir® 01.06010.303Prosthesis, hip, semi-constrained, metal/polymer, uncemented1 report
- Avenir® 01.06010.101Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented1 report
- Avenir® 01.06010.006Prosthesis, hip, hemi-, femoral, metal/polymer, cemented or uncemented1 report
- Avenir® 01.06010.106Prosthesis, hip, semi-constrained, uncemented, metal / polymer, non-porous, calcium phosphate1 report
Recent Avenir adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionApr 28, 2026Difficult to Insert; Peeled/Delaminated
IT WAS REPORTED THAT A PATIENT UNDERWENT A PRIMARY TOTAL HIP ARTHROPLASTY. DURING THE PROCEDURE, THE SURGERY ATTEMPTED TO FURTHER ADVANCE THE FEMORAL STEM TO CORRECT EXCESSIVE LEG LENGTHENING WHICH RESULTED IN A FISSURE OF THE FEMORAL SHAFT. THE STEM WAS REMOVED, AND CERCLAGE CABLES WERE PLACED AROUND THE SHAFT. UPON INSPECTION OF THE EXPLANTED STEM, THE SURGEON NOTED DAMAGE TO THE STEM COATING; THEREFORE, A NEW STEM OF THE SAME SIZE WAS USED. THE PROCEDURE WAS COMPLETED WITHOUT FURTHER COMPLICATIONS. DILIGENCE IS COMPLETED AND NO FURTHER INFORMATION ON THE REPORTED EVENT HAS BEEN PROVIDED.
Patient problems: Bone Fracture(s)
MAUDE report 25021654 ↗InjuryJan 8, 2026Adverse Event Without Identified Device or Use Problem
NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Extraskeletal ossification
MAUDE report 24007752 ↗InjurySep 17, 2025Loss of Osseointegration; Loss of Osseointegration
IT WAS REPORTED THAT PATIENT UNDERWENT A HIP REVISION 2 YEARS POST IMPLANTATION DUE TO STEM LOOSENING. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.
Patient problems: Aseptic loosening
MAUDE report 23074491 ↗InjuryApr 3, 2025Implant subsidence; Implant subsidence
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Failure of Implant
MAUDE report 21762556 ↗InjuryMar 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Pain
MAUDE report 21595269 ↗InjuryMar 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT HAD AN INITIAL RIGHT TOTAL HIP ARTHROPLASTY. THE PATIENT HAS HAD PAIN, DISCOMFORT, AMBULATION DIFFICULTIES, INSTABILITY, LEG LENGTH DISCREPANCY, DIFFICULTY WITH GETTING IN AND OUT OF VEHICLE, AND FEAR OF METAL TOXICITY SINCE INITIAL SURGERY. NO TREATMENT HAS BEEN REPORTED, AND ALL COMPONENTS REMAIN IMPLANTED. PATIENT WILL FOLLOW-UP WITH A NEW SURGEON APPROXIMATELY 9 MONTHS POST-IMPLANTATION. DILIGENCE IS COMPLETED AND NO FURTHER INFORMATION ON THE REPORTED EVENT HAS BEEN PROVIDED.
Patient problems: Ambulation or Postural Difficulties; Discomfort; Pain; Unequal Limb Length
MAUDE report 21548640 ↗InjuryFeb 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT APPROXIMATELY 6 YEARS POST IMPLANTATION OF A RIGHT TOTAL HIP ARTHROPLASTY, THE PATIENT ALLEGES PAIN IN HIP AND SEVERE ANAPHYLAXIS. IT IS UNKNOWN IF REVISION SURGERY IS PLANNED. DILIGENCE IS COMPLETED AND NO FURTHER INFORMATION ON THE REPORTED EVENT HAS BEEN PROVIDED.
Patient problems: Hypersensitivity/Allergic reaction; Pain
MAUDE report 21375106 ↗InjuryJan 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DILIGENCE IS COMPLETED AND NO FURTHER INFORMATION ON THE REPORTED EVENT HAS BEEN PROVIDED.
Patient problems: Bone Fracture(s); Periprosthetic fracture
MAUDE report 21114644 ↗InjuryNov 13, 2024Malposition of Device; Malposition of Device
IT WAS REPORTED THAT THE PATIENT UNDERWENT A HIP REVISION SURGERY APPROXIMATELY 2 YEARS POST IMPLANTATION DUE TO THE STEM IMPINGING ON THE CUP. THE STEM REMAINED IMPLANT. HEAD, LINER AND SHELL REPLACED. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.
Patient problems: Failure of Implant
MAUDE report 20674495 ↗InjuryOct 2, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS A REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY DUE TO PERIPROSTHETIC FRACTURE. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.
Patient problems: Bone Fracture(s)
MAUDE report 17849907 ↗InjuryAug 1, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Bone Fracture(s)
MAUDE report 17434285 ↗InjuryJul 19, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT HIP PROSTHESES IMPLANTATION APPROXIMATELY SEVEN (7) YEARS AGO. ABOUT SIX AND HALF (6,5) YEARS LATER PATIENT HAD A LOW ENERGY FALL AND SUSTAINED A B2 PERIPROSTHETIC FRACTURE. THE PATIENT UNDERWENT REVISION OF THE FEMORAL COMPONENT. THERE WAS MINIMAL BONE INGROWTH ON THE REMOVED STEM. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Bone Fracture(s); Fall
MAUDE report 17349072 ↗InjuryJul 18, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT HIP PROSTHESES IMPLANTATION APPROXIMATELY EIGHT (8) YEARS AGO. ABOUT SIX (6) YEARS LATER PATIENT HAD A LOW ENERGY FALL AND SUSTAINED A B2 PERIPROSTHETIC FRACTURE. THE PATIENT UNDERWENT REVISION OF THE FEMORAL COMPONENT. THERE WAS MINIMAL BONE INGROWTH ON THE REMOVED STEM. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Bone Fracture(s); Fall
MAUDE report 17341709 ↗InjuryJul 18, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT HIP PROSTHESES IMPLANTATION APPROXIMATELY NINE (9) YEARS AGO. ABOUT SEVEN (7) YEARS LATER PATIENT HAD A DOMESTIC FALL AND SUSTAINED A B2 PERIPROSTHETIC FRACTURE. THE PATIENT UNDERWENT REVISION OF THE FEMORAL COMPONENT. THERE WAS MINIMAL BONE INGROWTH ON THE REMOVED STEM. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Bone Fracture(s); Fall
MAUDE report 17341423 ↗InjuryJul 18, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT HIP PROSTHESES IMPLANTATION APPROXIMATELY FOUR AND HALF (4,5) YEARS AGO. ABOUT THREE AND HALF (3,5) YEARS LATER PATIENT HAD A DOMESTIC FALL AND SUSTAINED A B2 PERIPROSTHETIC FRACTURE.THE PATIENT UNDERWENT REVISION OF THE FEMORAL COMPONENT. THERE WAS MINIMAL BONE INGROWTH ON THE REMOVED STEM. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: Bone Fracture(s); Fall
MAUDE report 17341279 ↗
Other Zimmer GmbH products
- Affixus Natural Nail55 models · 612 reports
- Biolox delta16 models · 343 reports
- NCB78 models · 200 reports
- Zimmer Natural Nail System57 models · 187 reports
- Biolox Option16 models · 68 reports · 2 recalls
- Anatomical Shoulder33 models · 102 reports
- Sidus Stem-Free Shoulder9 models · 30 reports · 1 recall
- Wagner SL Revision33 models · 66 reports
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.