Avenir® 01.06010.001 (UDI 00889024479456)Recalls & reported problems
Zimmer GmbH · Class 2 · Implant
All models of Avenir (24)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00889024479456), received between Nov 7, 2018 and Sep 17, 2019 — classified as 3 injuries, 1 malfunction.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
1 FDA recall record name this device's identifier.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Oct 31, 2018Class IITerminated
Mislabeled Labeled Avenir Mller Stem size 1, the stem inside the packaging is an Avenir Mller Stem size 2 .
Z-0644-2019 · Root cause: Process control · Recall details · FDA record ↗
Most reported problems
Device problems
- Insufficient Device Problem Information2
- Device Markings/Labelling Problem1
- Inadequacy of Device Shape and/or Size1
- No Apparent Adverse Event1
Patient problems
- Hip Fracture1
- Loss of Range of Motion1
- No Code Available1
- No Consequences Or Impact To Patient1
- No Information1
- Pain1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjurySep 17, 2019Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size
IT WAS NOW REPORTED FROM THE CLINIC THAT THERE WAS NO SUITABLE CEMENTLESS SHAFT SIZE. SIZE 1 WAS TOO SMALL, SIZE 2 WAS TOO BIG. FOR THIS PATIENT A SIZE OF 1.5 WOULD BE SUITABLE, BUT THIS SIZE DOES NOT EXIST. THE SURGERY WAS FINISHED AFTER THE IMPLANTATION OF THE CEMENTED AVENIR STEM ¿ SIZE 2. IT WAS THEREFORE REPORTED THAT THERE WAS NO MALFUNCTION OF A ZIMMER BIOMET PRODUCT. THE PRODUCT (AVENIR STEM CEMENTED ¿ SIZE 2) HAS BEEN IMPLANTED ACCORDING TO SURGICAL TECHNIQUE. SINCE THIS EVENT DOES NOT REPRESENT AN ISSUE REGARDING THE PRODUCT BUT RATHER AN ISSUE REGARDING THE PRODUCT-PORTFOLIO, THIS CASE DOES NOT FULFILL THE CRITERIA OF A COMPLAINT ANYMORE. THIS CASE WILL BE INVALIDATED.
Patient problems: No Code Available
MAUDE report 9074342 ↗InjurySep 17, 2019No Apparent Adverse Event; Insufficient Device Problem Information; No Apparent Adverse Event; Insufficient Device Problem Information
INVESTIGATION RESULTS ARE NOW AVAILABLE.
Patient problems: Hip Fracture; No Information
MAUDE report 9074327 ↗InjuryAug 22, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
CLINICAL STUDY REPORTED THAT 5 YEAR AFTER IMPLANTATION PATIENT REPORTED MODERATE PAIN, DISCOMFORT, MARKEDLY SLOWER AND ALTERED GAIT MOVEMENT. THE PRODUCT IS STILL IMPLANTED.
Patient problems: Loss of Range of Motion; Pain
MAUDE report 8919649 ↗MalfunctionNov 7, 2018Device Markings/Labelling Problem; Device Markings/Labelling Problem
Other Prosthesis, hip, semi-constrained, metal/polymer, uncemented devices
- LFIT 6260-9-136Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, uncemented166 reports
- Trident 623-00-36EHowmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, uncemented112 reports
- Accolade 6021-0435Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, uncemented88 reports
- EXETER 0580-1-044Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, uncemented1 recall22 reports
- Endo-Model SL Knee Prosthesis System 16-2840/02WALDEMAR LINK GmbH & Co. KG · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented1 recall17 reports
- Endo-Model SL Knee Prosthesis System 16-2840/05WALDEMAR LINK GmbH & Co. KG · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented1 recall12 reports
- Trident 623-10-36EHowmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, uncemented57 reports
- LFIT 6260-9-336Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, uncemented56 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page