MaxGuard, MaxPlusRecalls & reported problems across all models
BD Switzerland Sàrl · 5 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 25
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls
- 0
We found 5 models of MaxGuard, MaxPlus by BD Switzerland Sàrl in the FDA's device registry (GUDID). Together they are named in 25 adverse event reports in the FDA's MAUDE database, received between Oct 18, 2018 and May 29, 2026 — classified as 1 injury, 24 malfunctions.
The most frequently reported specific device problem is “Crack” (8 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported MaxGuard, MaxPlus problems
Device problems
- Crack8
- Fluid/Blood Leak5
- Leak/Splash5
- Break4
- Defective Component4
- Connection Problem2
- Fracture2
- Incomplete or Inadequate Connection2
Patient problems
- No Clinical Signs, Symptoms or Conditions13
- No Consequences Or Impact To Patient10
- No Information3
- Insufficient Information1
- No Known Impact Or Consequence To Patient1
MaxGuard, MaxPlus models
5 models, most reported first. Each model has its own page with its reports, recalls and device details.
- MaxGuard, MaxPlus MP9220-CSet, administration, intravascular14 reports
- MaxGuard, MaxPlus MP9251-CSet, administration, intravascular7 reports
- MaxGuard, MaxPlus MP9002-CSet, administration, intravascular2 reports
- MaxGuard, MaxPlus MP9233-CSet, administration, intravascular1 report
- MaxGuard, MaxPlus MPXT1001-CSet, administration, intravascular1 report
Recent MaxGuard, MaxPlus adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionMay 29, 2026Crack; Leak/Splash
IT WAS REPORTED THAT BD MAXPLUS EXTENSION SET WAS DAMAGED. THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING VERBATIM IT WAS REPORTED BY CUSTOMER THAT IT WAS LEAKING FROM THE TRIFURCATE THAT WAS DIRECTLY CONNECTED TO THE PORT EXTENSION TUBING AND THAT THE HUB OF THE MALE CONNECTOR WAS CRACKED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25340961 ↗MalfunctionDec 29, 2025Leak/Splash; Leak/Splash
IT WAS REPORTED THAT BD MAXPLUS EXTENSION SET WAS LEAKING. THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING VERBATIM. IT WAS REPORTED BY CUSTOMER THAT FELT THE PART OF THE TRIFURCATE ATTACHED CRACK AND HAD TO USE A CLAMP TO DISCONNECT THE TRIFURCATE FROM THE CVC LINE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23918806 ↗MalfunctionDec 11, 2025Crack; Crack
IT WAS REPORTED THAT THE BD MAXGUARD MULTI-FUSE EXTENSION SET WITH NEEDLELESS CONNECTOR WAS CRACKED. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: AT APPROXIMATELY 0800, THE RN ATTEMPTED TO DRAW FROM THE PATIENT¿S CENTRAL VENOUS CATHETER (CVC). AFTER CLAMPING THE CVC, THE RN PROCEEDED TO DISCONNECT (TWIST OFF) THE TRIFURCATE THAT WAS ATTACHED TO THE PATIENT¿S TPN, LIPID INFUSION, AND HEPARIN DRIP. DURING THIS PROCESS, THE RN FELT THE TRIFURCATE CRACK AT THE POINT OF ATTACHMENT. TO DISCONNECT IT FROM THE CVC, A CLAMP WAS USED. THE RN THEN NOTIFIED THE CHARGE NURSE AND OBTAINED A NEW TRIFURCATE TO REATTACH, ENSURING CONTINUATION OF THE PATIENT¿S PN AND HEPARIN INFUSION. WAS PATIENT OR END-USER INJURED: UNK. WHEN WAS INCIDENT NOTICED: DURING USE. WAS INCIDENT DISCOVERED DURING DIRECT PATIENT CARE: Y. WAS ANY MEDICAL TREATMENT REQUIRED: UNK. WAS THERE ANY LEAKAGE? YES, THERE WAS MEDICATION/SODIUM CHLORIDE ON MY BED SHEET. THIS IS NOT A NEW ISSUE - IT HAS BEEN GOING ON AND OFF FOR AT LEAST A YEAR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23778273 ↗MalfunctionDec 11, 2025Crack; Crack
IT WAS REPORTED THAT THE BD MAXGUARD MULTI-FUSE EXTENSION SET WITH NEEDLELESS CONNECTOR WAS CRACKED. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: AT APPROXIMATELY 0800, THE RN ATTEMPTED TO DRAW FROM THE PATIENT¿S CENTRAL VENOUS CATHETER (CVC). AFTER CLAMPING THE CVC, THE RN PROCEEDED TO DISCONNECT (TWIST OFF) THE TRIFURCATE THAT WAS ATTACHED TO THE PATIENT¿S TPN, LIPID INFUSION, AND HEPARIN DRIP. DURING THIS PROCESS, THE RN FELT THE TRIFURCATE CRACK AT THE POINT OF ATTACHMENT. TO DISCONNECT IT FROM THE CVC, A CLAMP WAS USED. THE RN THEN NOTIFIED THE CHARGE NURSE AND OBTAINED A NEW TRIFURCATE TO REATTACH, ENSURING CONTINUATION OF THE PATIENT¿S PN AND HEPARIN INFUSION. WAS PATIENT OR END-USER INJURED: UNK. WHEN WAS INCIDENT NOTICED: DURING USE. WAS INCIDENT DISCOVERED DURING DIRECT PATIENT CARE: Y. WAS ANY MEDICAL TREATMENT REQUIRED: UNK. WAS THERE ANY LEAKAGE? YES THERE WAS MEDICATION/SODIUM CHLORIDE ON MY BED SHEET. THIS IS NOT A NEW ISSUE - IT HAS BEEN GOING ON AND OFF FOR AT LEAST A YEAR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23778271 ↗MalfunctionNov 18, 2025Connection Problem; Connection Problem
IT WAS REPORTED THAT BD MAXGUARD EXTENSION SET WAS DAMAGED. THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING: IT WAS REPORTED BY CUSTOMER THAT THE RN WENT TO DISCONNECT A TRI-FUSE FROM THE MICROCLAVE, BLUE CAP, CONNECTED TO THE PIV, THE TRI-FUSE HUB BROKE OFF FROM THE TUBING.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23588788 ↗MalfunctionJul 14, 2025Defective Component; Defective Component
IT WAS REPORTED THAT BD MAXGUARD EXTENSION SET WAS DAMAGED THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING VERBATIM IT WAS REPORTED BY CUSTOMER THAT THE LEUER END OF THE BD MAXPLUS TRI-FUSE EXTENSION SET (REF MP-9220-C; LOT25019330) WAS CRACKED. THIS WAS REPLACED BY BD MAXZERO MICROBORE TRIFUSE EXTENSION SET (REF MZ9266 LOT (10)23129280). AT BLOOD DRAW ON [DATE REDACTED] THE NEXT DAY, THE LEUER END OF THIS EXTENSION SET WAS FOUND TO ALSO BE CRACKED. REPLACED THIS WITH THE BD MAXZERO MICROBORE BIFUSE EXTENSION SET (REF MZ9265 LOT 24119278). UNFORTUNATELY, THE CONNECTION STARTED LEAKING AS SOON AS THE IVF [INTRAVENOUS FLUIDS] AND NAHCO3 [SODIUM BICARBONATE] INFUSION WAS STARTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22494174 ↗MalfunctionJun 11, 2025Defective Component; Incomplete or Inadequate Connection; Defective Component; Incomplete or Inadequate Connection
NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22189674 ↗MalfunctionJun 11, 2025Defective Component; Incomplete or Inadequate Connection; Defective Component; Incomplete or Inadequate Connection
IT WAS REPORTED THAT BD MAXGUARD MAXPLUS TRIFUSE EXTENSION SET WAS DAMAGED THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING VERBATIM IT WAS REPORTED BY CUSTOMER THAT BROKEN TRIFURCATE SET THAT WOULD NOT DISCONNECT FROM THE CAP. NURSING CHANGED THE CAPS AND TOOK OFF THE SET WITH THE CAP. HOWEVER, THE NEXT DAY WHEN DOING LABS, THE SAME SITUATION HAPPENED AND THEY HAD TO USE XXX CLAMPS TO DISCONNECT THE LEUR LOCK FROM THE CAP AND THEN CHANGE OUT THE ENTIRE SYSTEM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22189673 ↗MalfunctionMar 19, 2025Connection Problem; Connection Problem
IT WAS REPORTED THAT BD MAXGUARD PRESSURE RATED T-CONNECTOR EXTENSION SET WITH NEEDLELESS CONNECTOR WAS HARD TO CONNECT THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING VERBATIM IT WAS REPORTED BY CUSTOMER THAT EXTENSION SET IS DIFFICULT/VERY TIGHT TO CONNECT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21649443 ↗MalfunctionJan 29, 2025Leak/Splash; Leak/Splash
IT WAS REPORTED THAT BD MAXGUARD MULTI-FUSE EXTENSION SET WITH NEEDLELESS CONNECTOR WAS DAMAGED. THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING: IT WAS REPORTED BY CUSTOMER THAT THE ISSUES WERE RELATED TO LEAKING OR CRACKED MAX ZERO CAPS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21263425 ↗MalfunctionJan 9, 2025Crack; Crack
IT WAS REPORTED THAT BD MAXGUARD EXTENSION SET WAS DAMAGED THE FOLLOWING INFORMATION WAS RECEIVED BY THE INITIAL REPORTER WITH THE FOLLOWING VERBATIM IT WAS REPORTED BY CUSTOMER THAT THE TRIFURCATE CRACKED WHEN I DISCONNECTED HER LINE TO CONNECT PATIENT TO BLOOD FOR TRANSFUSION. VERBATIM:
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21120812 ↗MalfunctionNov 27, 2023Leak/Splash; Defective Component; Leak/Splash; Defective Component
NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 18212271 ↗MalfunctionJun 10, 2021Difficult to Remove; Difficult or Delayed Separation; Difficult to Remove; Difficult or Delayed Separation
IT WAS REPORTED THAT A 7 IN KINK REST EXTENSION SET W/MAXPLUS WAS DIFFICULT TO DISCONNECT DURING USE. THE FOLLOWING WAS REPORTED BY THE INITIAL REPORTER: "NEEDLESS CONNECTOR WILL NOT DISCONNECT FROM THE EXTENSION SET. UNABLE TO DO PROCEDURE IF IT IS NOT REMOVED. CONNECTOR WAS CHECKED BEFORE BEING USED ON A PATIENT, SO THERE WAS NO IMPACT ON PATIENT CARE."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11980358 ↗MalfunctionOct 17, 2020Leak/Splash; Leak/Splash
IT WAS REPORTED THAT 7-IN MINIBORE TRI-FUSE SET LEAKED. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO: MP9220-C BATCH NO: 20035960 IT WAS REPORTED THAT THERE WAS A LEAKAGE WHERE THE TUBING CONNECTS TO THE CLAVE. EVENT DESCRIPTION PER EMAIL STATES: PRODUCT DESCRIPTION: TRI-FUSE EXT SET MANUFACTURER NAME: BD DAMAGE XLEAK BREAK WAS THERE AN INJURY OR DEATH? Y N IF YES, COMPLETE AN EPSO REPORT AND QUARANTINE EQUIPMENT ACCORDING TO POLICY GEN-015 DATE INCIDENT OCCURRED: (B)(6) 2020 IS PRODUCT QUARANTINED Y N EQUIPMENT: MED WATCH COMPLETED? Y (...) DETAILS OF ISSUE: LEAKING WHERE THE TUBING CONNECTS TO THE CLAVE, SOME ARE NOT CREATING A GOOD SEAL.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10694560 ↗MalfunctionApr 1, 2020Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT THE EXTENSION SET LEAKED AT THE CONNECTION TO AN UNSPECIFIED MATING DEVICE. ALTHOUGH BLOOD AND IV FLUIDS LEAKED ONTO THE PATIENT'S CLOTHING, THERE WERE NO ADVERSE EFFECTS CAUSED TO THE PATIENT FROM THE EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9913455 ↗
Other BD Switzerland Sàrl products
- Alaris, SmartSite160 models · 10,227 reports · 8 recalls
- Alaris85 models · 2,797 reports · 10 recalls
- MaxZero47 models · 2,377 reports
- MaxGuard49 models · 780 reports · 11 recalls
- BD PhaSeal23 models · 992 reports · 2 recalls
- MaxPlus18 models · 762 reports · 2 recalls
- BD SmartSite29 models · 568 reports · 4 recalls
- Alaris, SmartSite, Texium12 models · 291 reports · 5 recalls
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page