Skip to content

Neuroguard IEP SystemRecalls & reported problems across all models

Contego Medical, Inc. · 8 models in the FDA device registry

Data updated Oct 16, 2026 from official FDA records · Editorial policy

2 open recalls name at least one Neuroguard IEP System model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.

Adverse event reports
67
Deaths reported
0
Injuries reported
7
Recalls
2

We found 8 models of Neuroguard IEP System by Contego Medical, Inc. in the FDA's device registry (GUDID). Together they are named in 67 adverse event reports in the FDA's MAUDE database, received between Jun 13, 2025 and Sep 18, 2026 — classified as 7 injuries, 60 malfunctions.

The most frequently reported specific device problem is “Activation Problem” (32 reports).

2 FDA recall records name at least one of these models by its device identifier, 2 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 9 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 2 reportsApr 2026: 2 reportsMay 2026: 2 reportsJun 2026: 7 reportsJul 2026: 32 reportsAug 2026: 5 reportsSep 2026: 3 reportsOct 2026: 0 reports20242025202632
Last 36 months. The most recent month may be incomplete.

Neuroguard IEP System recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Jun 29, 2026Open, Classified

    Carotid stent and post-dilation balloon system with integrated embolic protection system has an integrated filter, that due to a wire-to-filter-bond issue, may fail to open following sheath retraction; and if this condition were to occur during a procedure, the result may be loss of intended integrated embolic protection.

    Z-2911-2026 · Root cause: Process control · names 8 of these models · Recall details · FDA record ↗

  2. Sep 4, 2025Open, Classified

    Carotid stent and post-dilation balloon system with integrated embolic protection system has an integrated filter that may not open or may not fully open during sheath retraction and operation of the filter knob. The stent is used with a primary distal embolic protection device.

    Z-0131-2026 · Root cause: Device Design · names 4 of these models · Recall details · FDA record ↗

Most reported Neuroguard IEP System problems

Device problems

  • Activation Problem32
  • Difficult to Open or Close12
  • Use of Device Problem5
  • Activation Failure3
  • Adverse Event Without Identified Device or Use Problem3
  • Deformation Due to Compressive Stress3
  • Device Damaged by Another Device3
  • Material Deformation3

Patient problems

  • No Clinical Signs, Symptoms or Conditions61
  • Bradycardia2
  • Ischemia Stroke2
  • Muscle Weakness/Atrophy2
  • Dysphasia1
  • Ischemia1
  • Low Blood Pressure/ Hypotension1
  • Stroke/CVA1

Neuroguard IEP System models

8 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent Neuroguard IEP System adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page