RED 72Recalls & reported problems across all models
Penumbra, Inc. · 6 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 117
- Deaths reported
- 5
- Injuries reported
- 14
- Recalls
- 0
We found 6 models of RED 72 by Penumbra, Inc. in the FDA's device registry (GUDID). Together they are named in 117 adverse event reports in the FDA's MAUDE database, received between Oct 8, 2021 and Sep 29, 2026 — classified as 5 deaths, 14 injuries, 98 malfunctions.
The most frequently reported specific device problem is “Fracture” (62 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported RED 72 problems
Device problems
- Fracture62
- Physical Resistance/Sticking55
- Break34
- Material Deformation12
- Stretched12
- Unraveled Material10
- Adverse Event Without Identified Device or Use Problem5
- Leak/Splash5
Patient problems
- No Clinical Signs, Symptoms or Conditions97
- Foreign Body In Patient10
- Vascular Dissection5
- Thrombosis/Thrombus3
- Ischemia Stroke2
- Cerebral Edema1
- Embolism/Embolus1
- Foreign Body Embolism1
RED 72 models
6 models, most reported first. Each model has its own page with its reports, recalls and device details.
- RED 72 RED72KIT-ACatheter, Thrombus Retriever2 deaths57 reports
- RED 72 RED72SDKIT-ACatheter, Thrombus Retriever3 deaths29 reports
- RED 72 RED72-ACatheter, Thrombus Retriever18 reports
- RED 72 RED72SDKIT-BCatheter, Thrombus Retriever9 reports
- RED 72 RED72KIT-CCatheter, Thrombus Retriever3 reports
- RED 72 RED72-CCatheter, Thrombus Retriever1 report
Recent RED 72 adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 29, 2026Fracture
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50930803 ↗MalfunctionSep 15, 2026Fracture
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50777516 ↗InjuryJul 2, 2026Fracture
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE LEFT M1 SEGMENT OF THE MCA USING A PENUMBRA SYSTEM RED 72 SILVER REPERFUSION CATHETER (RED72 SILVER), A SENDIT DELIVERY DEVICE (SENDIT), A BENCHMARK BMX96 ACCESS SYSTEM (BMX96), AND A GUIDEWIRE. THE PHYSICIAN PLACED THE BMX96 IN THE COMMON CAROTID ARTERY (CCA) AND PERFORMED A CONTRAST RUN. THE RED72 SILVER AND THE SENDIT WERE ADVANCED TO THE FACE OF THE CLOT. WHILE RETRACTING THE SENDIT FROM THE RED72 SILVER, THE PHYSICIAN EXPERIENCED RESISTANCE. THE SENDIT AND THE RED72 SILVER WERE REMOVED TOGETHER. AFTER REMOVAL, THE PHYSICIAN NOTICED MULTIPLE KINKS ON THE DISTAL END OF THE RED72 SILVER. THE PHYSICIAN ADVANCED A NEW RED72 SILVER AND SENDIT TO THE TARGET LOCATION. THE SENDIT WAS REMOVED TO INITIATE ASPIRATION. AFTER THREE MINUTES OF ASPIRATION NO CLOT WAS ASPIRATED. THE RED72 SILVER WAS REMOVED AND FOUND TO BE FRACTURED AT THE DISTAL END. THE PROXIMAL PORTION WAS REMOVED FROM THE PATIENT. THE REMAINING PORTION EXTENDED FROM THE M1 SEGMENT TO THE EXTERNAL CAROTID ARTERY (ECA). MULTIPLE ATTEMPTS WERE MADE TO REMOVE THE REMAINING PORTION OF THE RED72 SILVER USING A SNARE DEVICE. THE REMAINING PORTION OF THE RED72 SILVER WAS L
Patient problems: Foreign Body In Patient
MAUDE report 25700455 ↗MalfunctionJul 1, 2026Fracture
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE RIGHT M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM RED 72 SILVER REPERFUSION CATHETER (RED72 SILVER), A NON-PENUMBRA SHEATH (7F), A NON-PENUMBRA MICROCATHETER, AND A GUIDEWIRE. THE RED72 SILVER WAS SUCCESSFULLY USED TO COMPLETE THE PROCEDURE. WHILE REMOVING THE RED72 SILVER FROM THE PATIENT IT WAS NOTICED UNDER FLUOROSCOPY THAT THE CATHETER FRACTURED. A SNARE DEVICE WAS USED TO REMOVE THE RED72 SILVER FROM THE PATIENT. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25685207 ↗MalfunctionJul 1, 2026Fracture
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE LEFT MIDDLE CEREBRAL ARTERY (MCA) USING THE PENUMBRA SYSTEM RED 72 SILVER REPERFUSION CATHETER (RED72 SILVER), A SENDIT DELIVERY DEVICE (SENDIT), A NEURON MAX 6F 088 SHEATH (NEURON MAX), AND A GUIDEWIRE. WHILE REMOVING THE SENDIT FROM THE RED72 SILVER, THE PHYSICIAN EXPERIENCED RESISTANCE. THE PHYSICIAN CONTINUED TO RETRACT THE SENDIT AND OBSERVED THAT THE SENDIT WAS FRACTURED UNDER FLUOROSCOPY. THE RED72 SILVER CONTAINING THE SENDIT WAS REMOVED. NO PART OF THE SENDIT WAS IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH ONE PASS USING ANOTHER RED72 SILVER, ANOTHER SENDIT, THE SAME NEURON MAX, AND THE SAME GUIDEWIRE. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25684742 ↗MalfunctionJun 24, 2026Fracture
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM RED 72 SILVER REPERFUSION CATHETER (RED72 SILVER), A SENDIT DELIVERY DEVICE (SENDIT), A NEURON MAX 6F 088 LONG SHEATH (NEURON MAX), AND A GUIDEWIRE. THE PATIENT¿S ANATOMY WAS NOTED TO BE TORTUOUS. THE RED72 SILVER AND SENDIT WERE ADVANCED OVER A GUIDEWIRE AND THROUGH THE NEURON MAX TO THE TARGET LOCATION, AND ASPIRATION WAS PERFORMED. THE PHYSICIAN DECIDED TO RETRACT THE RED72 SILVER. WHILE RETRACTING THE RED72 SILVER, THE PHYSICIAN EXPERIENCED RESISTANCE. THE RHV WAS CHECKED AND CONFIRMED NOT TO BE OVERLY TIGHTENED. THE PHYSICIAN CONTINUED TO RETRACT THE RED72 SILVER, AND NOTICED THAT THE DISTAL TIP WAS NOT MOVING. THE RED72 SILVER AND NEURON MAX WERE SUBSEQUENTLY REMOVED TOGETHER FROM THE PATIENT. ON THE BACK TABLE, THE DISTAL END OF THE RED72 SILVER WAS OBSERVED TO BE UNRAVELING WITHIN THE NEURON MAX. THE RED72 SILVER WAS NOT USED FOR THE REMAINDER OF THE PROCEDURE. THE PROCEDURE WAS COMPLETED USING A NEW RED72, THE SAME SENDIT, AND THE SAME NEURON MAX. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25609260 ↗MalfunctionJun 24, 2026Fracture
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA) USING A SENDIT DELIVERY DEVICE (SENDIT), A PENUMBRA RED 72 REPERFUSION SILVER CATHETER (RED72 SILVER), A BENCHMARK BMX96 ACCESS SYSTEM (BMX96), AND A GUIDEWIRE. IT WAS REPORTED THAT A LOOP WAS NOTICED IN THE INTERNAL CAROTID ARTERY (ICA). WHILE ADVANCING THE BMX96 TO THE TARGET LOCATION, THE PHYSICIAN EXPERIENCED RESISTANCE, BUT CONTINUED TO USE THE BMX96. THE PHYSICIAN ADVANCED THE RED72 SILVER, SENDIT, AND THE GUIDEWIRE THROUGH THE BMX96 TO THE TARGET LOCATION. THE SENDIT AND THE GUIDEWIRE WERE REMOVED FROM THE PATIENT TO INITIATE ASPIRATION. THE PHYSICIAN SUCCESSFULLY COMPLETED ONE PASS AND NOTICED THAT THE THE DISTAL END OF THE SENDIT AND GUIDEWIRE WERE ASPIRATED ALONG WITH THE CLOT INTO THE PENUMBRA ENGINE CANISTER (CANISTER). ALL PARTS OF THE SENDIT AND THE GUIDEWIRE WERE REMOVED FROM THE PATIENT, AND THE PROCEDURE WAS COMPLETED AT THIS POINT. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25608981 ↗InjuryApr 24, 2026Material Deformation
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE DISTAL M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM RED 72 SILVER REPERFUSION CATHETER (RED72 SILVER) AND A PENUMBRA ENGINE (ENGINE). THE PHYSICIAN ADVANCED THE RED72 SILVER TO THE FACE OF THE CLOT AND INITIATED ASPIRATION. DURING THE FIRST PASS, THE PHYSICIAN NOTICED THAT THERE WAS NO FLOW INTO THE CANISTER SO THE RED72 SILVER WAS REMOVED. UPON REMOVAL, THE THE RED72 WAS FOUND TO BE OVALIZED WITH CLOT IN ITS DISTAL TIP AND WAS REMOVED FROM THE PROCEDURE. SUBSEQUENTLY, A SMALL CLOT WAS IDENTIFIED TO HAVE EMBOLIZED IN THE M3 AND WAS TOO DISTAL TO ASPIRATE. A MICROCATHETER WAS THEN USED TO DELIVER A THROMBOLYTIC AGENT (ALTEPLASE) AND THE PROCEDURE WAS COMPLETED. THERE WAS NO ADDITIONAL ADVERSE EFFECT REPORTED.
Patient problems: Thromboembolism
MAUDE report 24987442 ↗MalfunctionMar 18, 2026Fracture
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE USING A PENUMBRA SYSTEM RED 72 REPERFUSION CATHETER (RED72). DURING THE PROCEDURE, THE RED72 FRACTURED DURING REMOVAL AFTER THE FIRST PASS. NO ADDITIONAL INFORMATION WAS PROVIDED. THE PROCEDURE WAS COMPLETED USING A NEW CATHETER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24630437 ↗MalfunctionMar 17, 2026Fracture; Physical Resistance/Sticking
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY USING A PENUMBRA SYSTEM RED 72 SILVER REPERFUSION CATHETER (RED72 SILVER), A SENDIT DELIVERY DEVICE (SENDIT), A BENCHMARK BMX96 ACCESS SYSTEM (BMX96), AND AN 8FR SHORT SHEATH. THE PHYSICIAN MADE ONE PASS IN THE TARGET LOCATION USING THE RED72 SILVER TO REMOVE CLOT. AFTER THE PASS, WHILE REMOVING THE RED72 SILVER WITH THE CLOT, THE PHYSICIAN EXPERIENCED RESISTANCE AND THE PROXIMAL END OF THE RED72 SILVER HAD FRACTURED. THE PROCEDURE WAS COMPLETED AT THIS POINT. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24617635 ↗MalfunctionJan 23, 2026Fracture; Material Deformation; Physical Resistance/Sticking
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE INTERNAL CAROTID ARTERY (ICA) USING A PENUMBRA SYSTEM RED 72 REPERFUSION CATHETER (RED72), A NEURON MAX 6F 088 LONG SHEATH (NEURON MAX), A NON-PENUMBRA MICROCATHETER, AND A GUIDEWIRE. DURING THE PROCEDURE, THE PHYSICIAN REPORTED THAT WHILE INTRODUCING THE RED72 BEFORE ANY PASSES WERE MADE, IT BECAME STUCK IN THE OPHTHALMIC SEGMENT OF THE ICA AND COULD NOT BE ADVANCED DISTALLY. WHILE ATTEMPTING TO RETRACT THE RED72 WITHIN THE NEURON MAX, THE PHYSICIAN OBSERVED UNDER FLUOROSCOPY THAT THE RED72 BECAME STRETCHED AND FRACTURED ON THE DISTAL LENGTH. HOWEVER, THE PHYSICIAN WAS ABLE TO SUCCESSFULLY REMOVE THE RED72, NEURON MAX, AND GUIDEWIRE TOGETHER FROM THE PATIENT. THE PROCEDURE WAS COMPLETED USING A STENT RETRIEVER AND THE SAME NEURON MAX. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24171065 ↗MalfunctionJan 9, 2026Fracture
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE RIGHT MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM RED 72 SILVER REPERFUSION CATHETER (RED72 SILVER), SENDIT DELIVERY DEVICE (SENDIT), A BALLOON GUIDE CATHETER, A NON-PENUMBRA ASPIRATION CATHETER, A NON-PENUMBRA MICROCATHETER, AND A NON-PENUMBRA STENT RETRIEVER. DURING THE PROCEDURE, THE PHYSICIAN MADE THREE PASSES IN THE RIGHT M1 USING THE THROMBUS RETRIEVAL ASPIRATION PLATFORM (TRAP) TECHNIQUE CONSISTING OF THE BALLOON GUIDE CATHETER, ASPIRATION CATHETER, MICROCATHETER, AND A STENT RETRIEVER RESULTING IN NO REPERFUSION. THE ASPIRATION SYSTEM WAS REMOVED TO BE REPLACED WITH A DIRECT ASPIRATION SYSTEM. A NEW GUIDE CATHETER WAS PLACED IN THE RIGHT INTERNAL CAROTID ARTERY (ICA). THE RED72 SILVER WITH SENDIT WERE ADVANCED OVER A GUIDEWIRE TO THE FACE OF THE CLOT. THE PHYSICIAN REMOVED THE SENDIT DEVICE AND GUIDEWIRE AND INITIATED ASPIRATION FOR APPROXIMATELY 90 SECONDS. UPON RETRACTION UNDER ASPIRATION, THE PHYSICIAN NOTICED THE DISTAL END OF THE RED72 SILVER REMAINED FIXED AT THE FACE OF THE CLOT. THE MICROCATHETER AND GUIDEWIRE WERE ADVANCED THROUGH THE RED72 SILVER TO ASSESS FOR A POTENTIAL KINK AND TO MAINTAIN WIRE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24030912 ↗MalfunctionDec 18, 2025Fracture; Stretched; Fracture; Stretched
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE DISTAL INTERNAL CAROTID ARTERY (ICA) USING A PENUMBRA SYSTEM RED 72 REPERFUSION CATHETER (RED72), A STENT RETRIEVER, AND A SHEATH. DURING THE PROCEDURE, THE PHYSICIAN COMPLETED THREE PASSES IN THE TARGET LOCATION USING THE RED72 AND THE STENT RETRIEVER. WHILE REMOVING THE RED72 FROM THE PATIENT, THE PHYSICIAN FOUND THAT IT WAS STRETCHED AND FRACTURED ON THE DISTAL LENGTH. THE DISTAL SEGMENT OF THE RED72 WAS REMOVED WHILE REMOVING THE STENT RETRIEVER FROM THE PATIENT. THE PROCEDURE WAS COMPLETED USING A NEW RED72 AND THE SAME SHEATH. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23845539 ↗MalfunctionDec 18, 2025Fracture; Stretched; Fracture; Stretched
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM RED 72 REPERFUSION CATHETER (RED72) AND A BENCHMARK BMX96 ACCESS SYSTEM (BMX96). DURING THE PROCEDURE, AFTER PERFORMING ONE PASS IN THE TARGET VESSEL USING THE RED72, THE PHYSICIAN DECIDED TO REMOVE THE RED72. WHILE RETRACTING THE RED72, THE PHYSICIAN NOTICED THAT THE DISTAL LENGTH OF THE CATHETER WAS NOT RETRACTING AND OBSERVED UNDER FLUOROSCOPY THAT THE RED72 WAS BECOMING STRETCHED AND DAMAGED. THE PHYSICIAN WAS THEN ABLE TO REMOVE THE ENTIRE RED72 FROM THE PATIENT. THE PROCEDURE WAS COMPLETED USING A NEW RED72 AND THE SAME BMX96. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23843594 ↗InjuryDec 15, 2025Fracture; Physical Resistance/Sticking; Fracture; Physical Resistance/Sticking
THE PATIENT WAS UNDERGOING A THROMBECTOMY PROCEDURE IN THE RIGHT MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SYSTEM RED 72 REPERFUSION CATHETER (RED72), A PENUMBRA SYSTEM ACE 68 REPERFUSION CATHETER (ACE68), A NON-PENUMBRA LONG SHEATH, A NON-PENUMBRA MICROCATHETER, A STENT RETRIEVER, AND A GUIDEWIRE. DURING THE PROCEDURE, AFTER PERFORMING TWO PASSES IN THE TARGET LOCATION USING THE ACE68, THE OCCLUSION OPENED SLIGHTLY. THE PHYSICIAN THEN DECIDED TO REMOVE THE ACE68 AND EXCHANGE IT FOR A RED72. WHILE PERFORMING THE NEXT PASS USING THE RED72, THE PHYSICIAN ATTEMPTED TO ASPIRATE AND RETRACT THE RED72; HOWEVER, RESISTANCE WAS ENCOUNTERED AND THE RED72 WAS NOT MOVING. THE PHYSICIAN MADE ANOTHER ATTEMPT TO RETRACT THE RED72 AND FRACTURED IT ON THE DISTAL LENGTH WITHIN THE MCA. ATTEMPTS WERE MADE TO REMOVE THE FRACTURED SEGMENT OF THE RED72 USING A SNARE DEVICE, THEN A STENT RETRIEVER, AND BY ADVANCING THE LONG SHEATH CLOSE TO THE TARGET LOCATION, WITHOUT SUCCESS. AFTER MULTIPLE UNSUCCESSFUL ATTEMPTS TO REMOVE THE FRACTURED SEGMENT OF THE RED72, THE PHYSICIAN DECIDED TO STOP THE PROCEDURE. THE PHYSICIAN THEN PERFORMED A LEFT SIDE ANGIOGRAM AND REPORTED THAT THE FLOW WAS GOOD, BUT THE FL
Patient problems: Foreign Body In Patient
MAUDE report 23812490 ↗
Other Penumbra, Inc. products
- RUBY Coil90 models · 2,838 reports
- Smart Coil98 models · 2,616 reports
- Penumbra System59 models · 2,164 reports · 4 recalls
- POD24 models · 1,947 reports
- Indigo System64 models · 1,873 reports
- Penumbra Coil 400120 models · 842 reports
- Lantern Delivery Catheter11 models · 817 reports
- LP Coil System38 models · 725 reports
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page