Smart CoilRecalls & reported problems across all models
Penumbra, Inc. · 98 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2,616
- Deaths reported
- 2
- Injuries reported
- 151
- Recalls
- 0
We found 98 models of Smart Coil by Penumbra, Inc. in the FDA's device registry (GUDID). Together they are named in 2,616 adverse event reports in the FDA's MAUDE database, received between Aug 20, 2015 and Mar 6, 2026 — classified as 2 deaths, 151 injuries, 2,463 malfunctions.
The most frequently reported specific device problem is “Failure to Advance” (1,466 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported Smart Coil problems
Device problems
- Failure to Advance1,466
- Physical Resistance/Sticking692
- Physical Resistance325
- Separation Failure228
- Difficult or Delayed Separation190
- Material Deformation105
- Adverse Event Without Identified Device or Use Problem99
- Premature Separation81
Patient problems
- No Consequences Or Impact To Patient1,852
- No Clinical Signs, Symptoms or Conditions821
- No Patient Involvement61
- Thrombus35
- Ischemia19
- Weakness17
- Neurological Deficit/Dysfunction15
- Infarction, Cerebral13
Smart Coil models
98 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Smart Coil 400SMTHXSFT0208DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Smart Coil 400SMTHXSFT0102DEVICE, NEUROVASCULAR EMBOLIZATION1 death115 reports
- Smart Coil 400SMTHXSFT0204DEVICE, NEUROVASCULAR EMBOLIZATION95 reports
- Smart Coil 400SMTHXSFT0103DEVICE, NEUROVASCULAR EMBOLIZATION94 reports
- Smart Coil 400SMTXSFT0103DEVICE, NEUROVASCULAR EMBOLIZATION84 reports
- Smart Coil 400SMTXSFT0306DEVICE, NEUROVASCULAR EMBOLIZATION77 reports
- Smart Coil 400SMTXSFT0308DEVICE, NEUROVASCULAR EMBOLIZATION75 reports
- Smart Coil 400SMTXSFT0204DEVICE, NEUROVASCULAR EMBOLIZATION69 reports
- Smart Coil 400SMTHXSFT1H03DEVICE, NEUROVASCULAR EMBOLIZATION66 reports
- Smart Coil 400SMTHXSFT2H06DEVICE, NEUROVASCULAR EMBOLIZATION60 reports
- Smart Coil 400SMTXSFT0208DEVICE, NEUROVASCULAR EMBOLIZATION59 reports
- Smart Coil 400SMTXSFT0102DEVICE, NEUROVASCULAR EMBOLIZATION58 reports
- Smart Coil 400SMTHXSFT1H02DEVICE, NEUROVASCULAR EMBOLIZATION58 reports
- Smart Coil 400SMTXSFT0410DEVICE, NEUROVASCULAR EMBOLIZATION56 reports
- Smart Coil 400SMTXSFT0206DEVICE, NEUROVASCULAR EMBOLIZATION52 reports
- Smart Coil 400SMTSFT0515DEVICE, NEUROVASCULAR EMBOLIZATION51 reports
- Smart Coil 400SMTHXSFT0306DEVICE, NEUROVASCULAR EMBOLIZATION50 reports
- Smart Coil 400SMTXSFT1H03DEVICE, NEUROVASCULAR EMBOLIZATION47 reports
- Smart Coil 400SMTXSFT0304DEVICE, NEUROVASCULAR EMBOLIZATION47 reports
- Smart Coil 400SMTHXSFT0206DEVICE, NEUROVASCULAR EMBOLIZATION46 reports
- Smart Coil 400SMTSFT0510DEVICE, NEUROVASCULAR EMBOLIZATION44 reports
- Smart Coil 400SMTSFT0408DEVICE, NEUROVASCULAR EMBOLIZATION43 reports
- Smart Coil 400SMTHXSFT0203DEVICE, NEUROVASCULAR EMBOLIZATION43 reports
- Smart Coil 400SMTHXSFT0308DEVICE, NEUROVASCULAR EMBOLIZATION42 reports
- Smart Coil 400SMTSFT0308DEVICE, NEUROVASCULAR EMBOLIZATION41 reports
- Smart Coil 400SMTXSFT2H04DEVICE, NEUROVASCULAR EMBOLIZATION38 reports
- Smart Coil 400SMTSFT0410DEVICE, NEUROVASCULAR EMBOLIZATION36 reports
- Smart Coil 400SMTHXSFT0202DEVICE, NEUROVASCULAR EMBOLIZATION36 reports
- Smart Coil 400SMTSFT0615DEVICE, NEUROVASCULAR EMBOLIZATION34 reports
- Smart Coil 400SMTHXSFT1H04DEVICE, NEUROVASCULAR EMBOLIZATION32 reports
- Smart Coil 400SMTXSFT0104DEVICE, NEUROVASCULAR EMBOLIZATION29 reports
- Smart Coil 400SMTHXSFT2H04DEVICE, NEUROVASCULAR EMBOLIZATION29 reports
- Smart Coil 400SMTSFT0306DEVICE, NEUROVASCULAR EMBOLIZATION28 reports
- Smart Coil 400SMTSFT0820DEVICE, NEUROVASCULAR EMBOLIZATION27 reports
- Smart Coil 400SMTXSFT0406DEVICE, NEUROVASCULAR EMBOLIZATION27 reports
- Smart Coil 400SMTXSFT0202DEVICE, NEUROVASCULAR EMBOLIZATION25 reports
- Smart Coil 400SMTXSFT0408DEVICE, NEUROVASCULAR EMBOLIZATION25 reports
- Smart Coil 400SMTXSFT1H02DEVICE, NEUROVASCULAR EMBOLIZATION24 reports
- Smart Coil 400SMTXSFT0203DEVICE, NEUROVASCULAR EMBOLIZATION24 reports
- Smart Coil 400SMTXSFT2H06DEVICE, NEUROVASCULAR EMBOLIZATION24 reports
- Smart Coil 400SMTHXSFT0101DEVICE, NEUROVASCULAR EMBOLIZATION21 reports
- Smart Coil 400SMTXSFT3H08DEVICE, NEUROVASCULAR EMBOLIZATION21 reports
- Smart Coil 400SMTHXSFT0408DEVICE, NEUROVASCULAR EMBOLIZATION20 reports
- Smart Coil 400SMTHXSFT0510DEVICE, NEUROVASCULAR EMBOLIZATION19 reports
- Smart Coil 400SMTXSFT011HDEVICE, NEUROVASCULAR EMBOLIZATION18 reports
- Smart Coil 400SMTXSFT3H06DEVICE, NEUROVASCULAR EMBOLIZATION18 reports
- Smart Coil 400SMTSFT0715DEVICE, NEUROVASCULAR EMBOLIZATION17 reports
- Smart Coil 400SMTSFT0406DEVICE, NEUROVASCULAR EMBOLIZATION17 reports
- Smart Coil 400SMTXSFT1H04DEVICE, NEUROVASCULAR EMBOLIZATION17 reports
- Smart Coil 400SMTSFT0304DEVICE, NEUROVASCULAR EMBOLIZATION16 reports
- Smart Coil 400SMTHXSFT0410DEVICE, NEUROVASCULAR EMBOLIZATION16 reports
- Smart Coil 400SMTSTD1260DEVICE, NEUROVASCULAR EMBOLIZATION15 reports
- Smart Coil 400SMTSTD0830DEVICE, NEUROVASCULAR EMBOLIZATION15 reports
- Smart Coil 400SMTSTD0725DEVICE, NEUROVASCULAR EMBOLIZATION15 reports
- Smart Coil 400SMTSTD0620DEVICE, NEUROVASCULAR EMBOLIZATION15 reports
- Smart Coil 400SMTSTD0515DEVICE, NEUROVASCULAR EMBOLIZATION14 reports
- Smart Coil 400SMTSFT0610DEVICE, NEUROVASCULAR EMBOLIZATION14 reports
- Smart Coil 400SMTXSFT0101DEVICE, NEUROVASCULAR EMBOLIZATION14 reports
- Smart Coil 400SMTSFT3H08DEVICE, NEUROVASCULAR EMBOLIZATION14 reports
- Smart Coil 400SMTSFT4H10DEVICE, NEUROVASCULAR EMBOLIZATION13 reports
- Smart Coil 400SMTSTD1460DEVICE, NEUROVASCULAR EMBOLIZATION11 reports
- Smart Coil 400SMTSTD1045DEVICE, NEUROVASCULAR EMBOLIZATION11 reports
- Smart Coil 400SMTSFT0203DEVICE, NEUROVASCULAR EMBOLIZATION11 reports
- Smart Coil 400SMTXSFT2H08DEVICE, NEUROVASCULAR EMBOLIZATION11 reports
- Smart Coil 400SMTSFT0506DEVICE, NEUROVASCULAR EMBOLIZATION10 reports
- Smart Coil 400SMTSTD1660DEVICE, NEUROVASCULAR EMBOLIZATION9 reports
- Smart Coil 400SMTXSFT2H03DEVICE, NEUROVASCULAR EMBOLIZATION9 reports
- Smart Coil 400SMTHXSFT0406DEVICE, NEUROVASCULAR EMBOLIZATION9 reports
- Smart Coil 400SMTHXSFT2H08DEVICE, NEUROVASCULAR EMBOLIZATION9 reports
- Smart Coil 400SMTSFT3H06DEVICE, NEUROVASCULAR EMBOLIZATION9 reports
- Smart Coil 400SMTXSFT4H12DEVICE, NEUROVASCULAR EMBOLIZATION9 reports
- Smart Coil 400SMTSTD0408DEVICE, NEUROVASCULAR EMBOLIZATION8 reports
- Smart Coil 400SMTHXSFT0304DEVICE, NEUROVASCULAR EMBOLIZATION8 reports
- Smart Coil 400SMTHXSFT0415DEVICE, NEUROVASCULAR EMBOLIZATION8 reports
- Smart Coil 400SMTSTD0615DEVICE, NEUROVASCULAR EMBOLIZATION7 reports
- Smart Coil 400SMTSFT0930DEVICE, NEUROVASCULAR EMBOLIZATION7 reports
- Smart Coil 400SMTSTD0930DEVICE, NEUROVASCULAR EMBOLIZATION6 reports
- Smart Coil 400SMTXSFT0205DEVICE, NEUROVASCULAR EMBOLIZATION6 reports
- Smart Coil 400SMTHXSFT1H01DEVICE, NEUROVASCULAR EMBOLIZATION6 reports
- Smart Coil 400SMTSTD1360DEVICE, NEUROVASCULAR EMBOLIZATION5 reports
- Smart Coil 400SMTSTD1860DEVICE, NEUROVASCULAR EMBOLIZATION5 reports
- Smart Coil 400SMTSTD0820DEVICE, NEUROVASCULAR EMBOLIZATION5 reports
- Smart Coil 400SMTSTD0715DEVICE, NEUROVASCULAR EMBOLIZATION4 reports
- Smart Coil 400SMTSTD0510DEVICE, NEUROVASCULAR EMBOLIZATION4 reports
- Smart Coil 400SMTSTD1545DEVICE, NEUROVASCULAR EMBOLIZATION3 reports
- Smart Coil 400SMTSTD1345DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTSTD1445DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTSTD1030DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTSTD1145DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTSTD1160DEVICE, NEUROVASCULAR EMBOLIZATION1 death2 reports
- Smart Coil 400SMTSTD1245DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTSTD0410DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTSFT0720DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTHXSFT0420DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- Smart Coil 400SMTSTD1560DEVICE, NEUROVASCULAR EMBOLIZATION1 report
- Smart Coil 400SMTSTD1135DEVICE, NEUROVASCULAR EMBOLIZATION1 report
- Smart Coil 400SMTSFT1030DEVICE, NEUROVASCULAR EMBOLIZATION1 report
- Smart Coil 400SMTHXSFT4H15DEVICE, NEUROVASCULAR EMBOLIZATION1 report
Recent Smart Coil adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionMar 6, 2026Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A RECOILING EMBOLIZATION PROCEDURE IN THE LEFT ANTERIOR COMMUNICATING ARTERY (ACOM) USING A SMART COIL (SMART COIL), A SMART COIL DETACHMENT HANDLE (HANDLE), A NON-PENUMBRA MICROCATHETER, AN INTERMEDIATE CATHETER, AND A GUIDEWIRE. IT WAS REPORTED THAT THE TARGET VESSEL WAS PREVIOUSLY COILED USING STENT SUPPORT. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL INTO THE TARGET VESSEL USING THE MICROCATHETER AND ATTEMPTED TO DETACH IT USING THE HANDLE. HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN MADE ADDITIONAL ATTEMPTS TO DETACH THE SMART COIL USING A SECOND HANDLE AND VIA MANUAL DETACHMENT; HOWEVER, THE SMART COIL WOULD STILL NOT DETACH. THE PHYSICIAN THEN DECIDED TO REMOVE THE SMART COIL. WHILE REMOVING THE SMART COIL, THE COIL UNINTENTIONALLY DETACHED WITHIN THE MICROCATHETER. THE PHYSICIAN USED THE PUSHER ASSEMBLY OF THE SMART COIL TO SUCCESSFULLY PUSH THE DETACHED SMART COIL INTO THE ANEURYSM. THE PROCEDURE WAS COMPLETED USING ADDITIONAL SMART COILS AND A NEW HANDLE. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24530948 ↗MalfunctionAug 27, 2025Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE MIDDLE MENINGEAL ARTERY (MMA) USING PENUMBRA SMART COILS (SMART COIL), A PENUMBRA SMART COIL DETACHMENT HANDLE (HANDLE) AND A NON-PENUMBRA MICROCATHETER. IT SHOULD BE NOTED THAT THE PATIENT'S ANATOMY WAS MILDLY TORTUOUS AND MILDLY CALCIFIED. DURING THE PROCEDURE, THE PHYSICIAN SUCCESSFULLY IMPLANTED A SMART COIL INTO THE TARGET LOCATION USING THE HANDLE. AFTER ADVANCING ANOTHER SMART COIL INTO THE TARGET VESSEL, THE PHYSICIAN ATTEMPTED TO DETACH IT USING THE HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN REMOVED AND REINSERTED THE PUSHER ASSEMBLY OF THE SMART COIL INTO THE HANDLE AND MADE ANOTHER ATTEMPT TO DETACH IT USING THE HANDLE; HOWEVER, THE SMART COIL STILL DID NOT DETACH. THE PHYSICIAN ATTEMPTED TO MANUALLY DETACH THE SMART COIL, BUT THE SMART COIL STILL DID NOT DETACH. WHILE ATTEMPTING TO RETRACT THE SMART COIL AND REMOVE IT FROM THE PATIENT, THE COIL UNINTENTIONALLY DETACHED. HOWEVER, THE SMART COIL WAS ABLE TO BE REMOVED FROM THE PATIENT MANUALLY. THE PROCEDURE WAS COMPLETED BY USING A NON-PENUMBRA COIL. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22908935 ↗MalfunctionAug 21, 2025Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE RIGHT POSTERIOR COMMUNICATING ARTERY (PCOMM) USING A PENUMBRA SMART COIL (SMART COIL) AND A NON-PENUMBRA MICROCATHETER. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL INTO THE TARGET LOCATION AND MANUALLY DETACHED THE SMART COIL INTO THE TARGET LOCATION. WHILE RETRACTING THE SMART COIL PUSHER ASSEMBLY, THE PHYSICIAN FELT SOMETHING HUNG ON TO THE SMART COIL PUSHER ASSEMBLY AND THE SMART COIL WAS SLIGHTLY PULLED OUT OF THE ANEURYSM BEFORE FULLY DETACHING. IT WAS NOTED THAT THE LAST IMAGING REVEALED THAT THE TAIL END OF THE EMBOLIZATION COIL WAS IN THE PARENT VESSEL AND WAS NOT INSIDE THE MICROCATHETER. THE PHYSICIAN THEN USED THE SMART COIL PUSHER ASSEMBLY AND THE MICROCATHETER TO PUSH THE SMART COIL BACK INTO THE TARGET LOCATION, BUT A SMALL PART OF THE SMART COIL WAS STILL LEFT FREE FLOWING IN THE PARENT VESSEL. THE PHYSICIAN DECIDED TO LEAVE THE SMART COIL IN THE PCOMM AS THERE WAS NO HARM TO THE PATIENT. THE PROCEDURE WAS COMPLETED AT THIS POINT.
Patient problems: Foreign Body In Patient
MAUDE report 22865221 ↗MalfunctionApr 23, 2025Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION IN THE PENILE ARTERY USING PENUMBRA SMART COILS (SMART COILS), PENUMBRA SMART COIL DETACHMENT HANDLES (HANDLES), AND A MICROCATHETER. DURING THE PROCEDURE, THE PHYSICIAN SUCCESSFULLY IMPLANTED TWO SMART COILS INTO THE TARGET VESSEL USING THE HANDLE. AFTER ADVANCING THE THIRD SMART COIL INTO THE TARGET LOCATION, THE PHYSICIAN ATTEMPTED TO DETACH THE COIL USING THE HANDLE; HOWEVER, THE COIL WOULD NOT DETACH. THEREFORE, THE HANDLE WAS REMOVED AND WAS NO LONGER USED IN THE PROCEDURE. THE PHYSICIAN THEN ATTEMPTED TO USE A SECOND HANDLE TO DETACH THE SAME SMART COIL; HOWEVER, THE COIL STILL DID NOT DETACH. WHILE ATTEMPTING TO MANUALLY DETACH THE SMART COIL, THE COIL WAS INADVERTENTLY PULLED BACK INTO THE MICROCATHETER AND DETACHED WITHIN THE DISTAL END OF THE MICROCATHETER. THE PHYSICIAN THEN USED THE SMART COIL PUSHER ASSEMBLY TO SUCCESSFULLY IMPLANT THE COIL INTO THE TARGET LOCATION. THE PROCEDURE WAS COMPLETED USING THREE ADDITIONAL SMART COILS, THE SECOND HANDLE, AND THE SAME MICROCATHETER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21896096 ↗MalfunctionSep 6, 2024Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE MIDDLE CEREBRAL ARTERY (MCA) USING A PENUMBRA SMART COIL (SMART COIL), PENUMBRA SMART COIL DETACHMENT HANDLES (HANDLE), AND A NON-PENUMBRA MICROCATHETER. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL INTO THE TARGET VESSEL USING THE MICROCATHETER AND ATTEMPTED TO DETACH IT USING A HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH AFTER MULTIPLE ATTEMPTS. THE PHYSICIAN THEN MADE MULTIPLE ATTEMPTS TO DETACH THE SMART COIL USING A SECOND HANDLE; HOWEVER, THE SMART COIL DID NOT DETACH. THEREFORE, THE PHYSICIAN DECIDED TO RE-SHEATH THE SMART COIL. WHILE RETRACTING, THE SMART COIL UNINTENTIONALLY DETACHED WITH HALF OF THE SMART COIL STILL IN THE ANEURYSM AND THE OTHER HALF IN THE MCA. THE PHYSICIAN THEN USED THE MICROCATHETER TO SUCCESSFULLY PUSH THE DETACHED SMART COIL BACK INTO THE ANEURYSM. THE PROCEDURE WAS COMPLETED USING OTHER COILS. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20163650 ↗MalfunctionApr 19, 2024Unraveled Material; Physical Resistance/Sticking; Premature Separation; Unraveled Material; Physical Resistance/Sticking; Premature Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE USING PENUMBRA SMART COILS (SMART COILS) AND A NON-PENUMBRA MICROCATHETER. IT SHOULD BE NOTED THAT THE PATIENT'S ANATOMY WAS TORTUOUS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED A SMART COIL INTO THE TARGET LOCATION AND REPORTED THAT IT WAS NOT TAKING ITS INTENDED SHAPE. THEREFORE, THE SMART COIL WAS REMOVED. WHILE ADVANCING ANOTHER SMART COIL OF THE SAME SIZE THROUGH THE MICROCATHETER, THE PHYSICIAN EXPERIENCED RESISTANCE AND NOTICED UNDER FLUOROSCOPY THAT THE SMART COIL WAS UNRAVELED WITHIN THE MICROCATHETER AND HAD BECOME STUCK. THE PHYSICIAN THEN DECIDED TO REMOVE THE SMART COIL AND NOTICED THAT IT HAD UNINTENTIONALLY DETACHED INSIDE THE MICROCATHETER. THEREFORE, THE MICROCATHETER CONTAINING THE SMART COIL WAS REMOVED FROM THE PATIENT. AT THIS POINT, THE PHYSICIAN LACKED SMALLER COIL OPTIONS TO BE ABLE TO PROCEED WITH THE PROCEDURE AND THEREFORE, THE PROCEDURE WAS SUSPENDED. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19148901 ↗MalfunctionOct 13, 2023Premature Separation; Premature Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE ANTERIOR COMMUNICATING ARTERY (ACOM) USING PENUMBRA SMART COILS (SMART COILS), A PENUMBRA SMART COIL HANDLE (HANDLE), A NON-PENUMBRA MICROCATHETER, AND A GUIDEWIRE. IT WAS NOTED THAT THE PATIENT''S ANATOMY WAS TORTUOUS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED A SMART COIL USING THE MICROCATHETER INTO THE TARGET LOCATION AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE. HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN THEN ATTEMPTED TO MANUALLY DETACH THE SMART COIL THREE TIMES WITHOUT SUCCESS. WHILE ATTEMPTING TO RETRACT THE SMART COIL, THE SMART COIL UNINTENTIONALLY DETACHED. THE PHYSICIAN USED THE GUIDEWIRE TO PUSH THE SMART COIL INTO THE VESSEL AND FLUSHED IT. THE PHYSICIAN THEN ADVANCED ANOTHER SMART COIL INTO THE TARGET LOCATION AND ATTEMPTED TO DETACH IT USING THE HANDLE. HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN THEN ATTEMPTED TO DETACH THE SMART COIL MANUALLY BUT WAS UNSUCCESSFUL. THE SMART COIL WAS THEN REMOVED. THE PROCEDURE WAS COMPLETED USING ANOTHER COIL AND A NEW MICROCATHETER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17932595 ↗InjurySep 29, 2023Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE M2 BRANCH OF THE MIDDLE CEREBRAL ARTERY (MCA) USING PENUMBRA SMART COILS (SMART COIL), A PENUMBRA SMART COIL DETACHMENT HANDLE (HANDLE), AND A NON-PENUMBRA MICROCATHETER. IT WAS NOTED THAT THE PATIENT¿S ANATOMY WAS TORTUOUS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL USING A MICROCATHETER INTO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN ATTEMPTED TO MANUALLY DETACH THE SMART COIL; HOWEVER, IT WOULD STILL NOT DETACH. THEREFORE, THE PHYSICIAN DECIDED TO REMOVE THE SMART COIL. WHILE RETRACTING, THE SMART COIL UNINTENTIONALLY DETACHED WITHIN THE MICROCATHETER. THE PHYSICIAN THEN USED A MICROWAVE TO ADVANCE THE SMART COIL OUT OF THE MICROCATHETER AND INTO THE TARGET VESSEL. NEXT, THE PHYSICIAN PLACED TWO SMART COILS IN THE TARGET LOCATION SUCCESSFULLY. THE PHYSICIAN THEN ADVANCED A FOURTH SMART COIL TO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN ATTEMPTED TO MANUALLY DETACH THE SMART COIL; HOWEVER, IT WOULD NOT DETACH. WHILE RETRACTING
Patient problems: Thrombosis/Thrombus
MAUDE report 17844127 ↗InjurySep 29, 2023Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE M2 BRANCH OF THE MIDDLE CEREBRAL ARTERY (MCA) USING PENUMBRA SMART COILS (SMART COIL), A PENUMBRA SMART COIL DETACHMENT HANDLE (HANDLE), AND A NON-PENUMBRA MICROCATHETER. IT WAS NOTED THAT THE PATIENT¿S ANATOMY WAS TORTUOUS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL USING A MICROCATHETER INTO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN ATTEMPTED TO MANUALLY DETACH THE SMART COIL; HOWEVER, IT WOULD STILL NOT DETACH. THEREFORE, THE PHYSICIAN DECIDED TO REMOVE THE SMART COIL. WHILE RETRACTING, THE SMART COIL UNINTENTIONALLY DETACHED WITHIN THE MICROCATHETER. THE PHYSICIAN THEN USED A MICROWAVE TO ADVANCE THE SMART COIL OUT OF THE MICROCATHETER AND INTO THE TARGET VESSEL. NEXT, THE PHYSICIAN PLACED TWO SMART COILS IN THE TARGET LOCATION SUCCESSFULLY. THE PHYSICIAN THEN ADVANCED A FOURTH SMART COIL TO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN ATTEMPTED TO MANUALLY DETACH THE SMART COIL; HOWEVER, IT WOULD NOT DETACH. WHILE RETRACTING
Patient problems: Thrombosis/Thrombus
MAUDE report 17844126 ↗InjurySep 29, 2023Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE M2 BRANCH OF THE MIDDLE CEREBRAL ARTERY (MCA) USING PENUMBRA SMART COILS (SMART COIL), A PENUMBRA SMART COIL DETACHMENT HANDLE (HANDLE), AND A NON-PENUMBRA MICROCATHETER. IT WAS NOTED THAT THE PATIENT¿S ANATOMY WAS TORTUOUS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL USING A MICROCATHETER INTO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN ATTEMPTED TO MANUALLY DETACH THE SMART COIL; HOWEVER, IT WOULD STILL NOT DETACH. THEREFORE, THE PHYSICIAN DECIDED TO REMOVE THE SMART COIL. WHILE RETRACTING, THE SMART COIL UNINTENTIONALLY DETACHED WITHIN THE MICROCATHETER. THE PHYSICIAN THEN USED A MICROWAVE TO ADVANCE THE SMART COIL OUT OF THE MICROCATHETER AND INTO THE TARGET VESSEL. NEXT, THE PHYSICIAN PLACED TWO SMART COILS IN THE TARGET LOCATION SUCCESSFULLY. THE PHYSICIAN THEN ADVANCED A FOURTH SMART COIL TO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE; HOWEVER, THE SMART COIL FAILED TO DETACH. THE PHYSICIAN ATTEMPTED TO MANUALLY DETACH THE SMART COIL; HOWEVER, IT WOULD NOT DETACH. WHILE RETRACTING
Patient problems: Thrombosis/Thrombus
MAUDE report 17844125 ↗MalfunctionAug 2, 2023Difficult or Delayed Separation; Premature Separation; Difficult or Delayed Separation; Premature Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE MIDDLE MENINGEAL ARTERY (MMA) USING PENUMBRA SMART COILS (SMART COIL), A SMART COIL DETACHMENT HANDLE (HANDLE), A NON-PENUMBRA MICROCATHETER, AND A GUIDEWIRE. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED A SMART COIL USING A MICROCATHETER INTO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE TWO TIMES; HOWEVER, THE SMART COIL FAILED TO DETACH. THEREFORE, THE PHYSICIAN DECIDED TO REMOVE THE SMART COIL. WHILE RETRACTING, THE SMART COIL UNINTENTIONALLY DETACHED WITHIN THE MICROCATHETER. THE PHYSICIAN THEN USED THE DETACHED SMART COIL''S PUSHER WIRE TO ADVANCE THE SMART COIL OUT OF THE MICROCATHETER AND INTO THE TARGET VESSEL. THE PROCEDURE WAS COMPLETED USING A NON-PENUMBRA COIL AND THE SAME MICROCATHETER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17446153 ↗MalfunctionJul 27, 2023Difficult or Delayed Separation; Premature Separation; Difficult or Delayed Separation; Premature Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE MIDDLE MENINGEAL ARTERY (MMA) USING PENUMBRA SMART COILS (SMART COIL), SMART COIL DETACHMENT HANDLES (HANDLE), A NON-PENUMBRA MICROCATHETER, AND A GUIDEWIRE. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED A SMART COIL USING A MICROCATHETER INTO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE HANDLE SEVERAL TIMES; HOWEVER, THE SMART COIL FAILED TO DETACH. THEN THE PHYSICIAN USED A SECOND HANDLE WITHOUT SUCCESS. THEREFORE, THE PHYSICIAN DECIDED TO REMOVE THE SMART COIL. WHILE RETRACTING, THE SMART COIL UNINTENTIONALLY DETACHED WITHIN THE MICROCATHETER. THE PHYSICIAN THEN USED THE DETACHED SMART COIL''S PUSHER WIRE TO ADVANCE THE SMART COIL OUT OF THE MICROCATHETER AND INTO THE TARGET VESSEL. NEXT, THE PHYSICIAN ADVANCED A SECOND SMART COIL INTO THE TARGET VESSEL AND ATTEMPTED TO DETACH THE SMART COIL USING THE SECOND HANDLE; HOWEVER, THE SMART COIL WOULD NOT DETACH. THEREFORE, THE SMART COIL WAS REMOVED. THE PROCEDURE WAS COMPLETED USING A NON-PENUMBRA COIL AND THE SAME MICROCATHETER. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17402770 ↗MalfunctionJul 6, 2023Difficult or Delayed Separation; Difficult or Delayed Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE INTERNAL ILIAC ARTERY (IIA) USING A PENUMBRA SMART COIL (SMART COIL), A PENUMBRA SMART COIL DETACHMENT HANDLE (HANDLE), AND A NON-PENUMBRA MICROCATHETER. IT WAS NOTED THAT THE PATIENT¿S ANATOMY WAS MODERATELY TORTUOUS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL INTO THE TARGET VESSEL USING THE MICROCATHETER, THEN ATTEMPTED TO DETACH IT USING THE HANDLE. HOWEVER, THE SMART COIL FAILED TO DETACH. AFTER MULTIPLE FAILED ATTEMPTS TO DETACH THE SMART COIL USING THE HANDLE, THE PHYSICIAN DECIDED TO REMOVE THE SMART COIL. WHILE RETRACTING THE SMART COIL, IT UNINTENTIONALLY DETACHED WITHIN THE MICROCATHETER. THEREFORE, THE MICROCATHETER CONTAINING THE SMART COIL WAS REMOVED AND THE COIL WAS FLUSHED OUT. THE PROCEDURE WAS COMPLETED USING TWO NEW SMART COILS, A NEW HANDLE, AND FOUR NON-PENUMBRA COILS. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17275036 ↗MalfunctionJun 21, 2023Premature Separation; Premature Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE MIDDLE CEREBRAL ARTERY (MCA) USING PENUMBRA SMART COILS (SMART COIL), A SMART COIL DETACHMENT HANDLE (HANDLE), A BENCHMARK 6F 071 DELIVERY CATHETER (BENCHMARK) AND TWO NON-PENUMBRA MICROCATHETERS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED A SMART COIL INTO THE TARGET VESSEL USING A MICROCATHETER, THEN ATTEMPTED TO DETACH IT USING THE HANDLE. IT WAS REPORTED THAT THE PUSHER ASSEMBLY OF THE SMART COIL HAD SUGGESTED THAT THE SMART COIL WAS DETACHED INTO THE TARGET VESSEL. HOWEVER, WHILE REMOVING THE PUSHER ASSEMBLY AND CATHETER, THE PHYSICIAN NOTICED UNDER FLUOROSCOPY THAT THE SMART COIL HAD UNINTENTIONALLY DETACHED OUTSIDE OF THE TARGET VESSEL. THE PHYSICIAN THEN ATTEMPTED TO PUSH THE SMART COIL INTO THE TARGET VESSEL USING THE MICROCATHETER; HOWEVER, THE MICROCATHETER KICKED OUT OF THE TARGET VESSEL. SUBSEQUENTLY, THE SMART COIL MOVED A FEW CENTIMETERS OUTSIDE OF THE TARGET VESSEL. THE MICROCATHETER WAS THEN REMOVED, AND THE PHYSICIAN SUCCESSFULLY REMOVED THE SMART COIL USING THE NON-PENUMBRA CATHETER AND A SNARE DEVICE. THE PHYSICIAN THEN ADVANCED ANOTHER SMART COIL INTO THE TARGET VESSEL USING THE MICROCATHETER, TH
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17178112 ↗MalfunctionJun 5, 2023Premature Separation; Premature Separation
THE PATIENT WAS UNDERGOING A COIL EMBOLIZATION PROCEDURE IN THE ANTERIOR COMMUNICATING ARTERY (ACOM) USING A PENUMBRA SMART COIL (SMART COIL), A SMART COIL DETACHMENT HANDLE (HANDLE) AND A NON-PENUMBRA MICROCATHETER. IT WAS NOTED THAT THE PATIENT¿S ANATOMY WAS TORTUOUS. DURING THE PROCEDURE, THE PHYSICIAN ADVANCED THE SMART COIL INTO THE TARGET LOCATION AND ATTEMPTED TO DETACH IT USING THE HANDLE; HOWEVER, THE SMART COIL WOULD NOT DETACH. THE PHYSICIAN THEN ATTEMPTED TO MANUALLY DETACH THE COIL BUT THE SMART COIL STILL WOULD NOT DETACH. THEREFORE, THE PHYSICIAN DECIDED TO RETRACT THE SMART COIL. WHILE RETRACTING, THE SMART COIL UNINTENTIONALLY DETACHED IN THE MICROCATHETER. SUBSEQUENTLY, THE PHYSICIAN PUSHED THE DETACHED SMART COIL INTO THE TARGET VESSEL USING THE PUSHER ASSEMBLY. THE PROCEDURE WAS COMPLETED USING NON-PENUMBRA COILS AND A NON-PENUMBRA HANDLE. THERE WAS NO REPORT OF AN ADVERSE EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17056628 ↗
Other Penumbra, Inc. products
- RUBY Coil90 models · 2,838 reports
- Penumbra System59 models · 2,164 reports · 4 recalls
- POD24 models · 1,947 reports
- Indigo System64 models · 1,873 reports
- Penumbra Coil 400120 models · 842 reports
- Lantern Delivery Catheter11 models · 817 reports
- LP Coil System38 models · 725 reports
- Neuron36 models · 517 reports
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page