TegadermRecalls & reported problems across all models
3m Company · 4 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 20
- Deaths reported
- 1
- Injuries reported
- 19
- Recalls
- 0
We found 4 models of Tegaderm by 3m Company in the FDA's device registry (GUDID). Together they are named in 20 adverse event reports in the FDA's MAUDE database, received between Jul 17, 2018 and Jun 28, 2023 — classified as 1 death, 19 injuries.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Most reported Tegaderm problems
Device problems
- Adverse Event Without Identified Device or Use Problem13
- Patient Device Interaction Problem6
- Improper or Incorrect Procedure or Method2
- Insufficient Device Problem Information1
- Patient-Device Incompatibility1
Patient problems
- Skin Irritation6
- Erythema4
- Reinfusion3
- No Code Available2
- Reaction2
- Cellulitis1
- Death1
- Fluid Discharge1
Tegaderm models
4 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Tegaderm™ 1657Dressing, Wound, Drug1 death11 reports
- Tegaderm™ 1665Dressing, wound, drug5 reports
- Tegaderm™ 1877-2100Dressing, wound, drug3 reports
- Tegaderm™ 1660Dressing, wound, drug1 report
Recent Tegaderm adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
InjuryJun 28, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
A HOSPITAL REPORTED A 1.5CM X 1.5CM BURN-LIKE SKIN LESION, YELLOWISH WHITE TISSUE, CLEAR MARGINS, MEDIUM SEROUS EXUDATE, AND PERIPHERAL REDNESS ON AN 8-MONTH-OLD FEMALE PATIENT AFTER USE OF 1660R TEGADERM CHG. SYMPTOMS STARTED AFTER FIVE DAYS OF WEAR ON THE PATIENT'S RIGHT JUGULAR VEIN. THE CHG PAD WAS SLIGHTED SATURATED UPON DRESSING CHANGE AND THE IRRITATION WAS FOUND UNDER THE CHG PAD. UPON REMOVING THE DRESSING, THE PEDIATRIC PATIENT WAS CRYING. THERE WERE NO DIFFICULTIES REMOVING THE DRESSING. TOPICAL TREATMENT WHILE USING POLYURETHANE FOAM WITH SILVER, HYDROGEL, AND PORTABLE LOW POWER LASER THERAPY. ANESTHESIA WAS NOT REQUIRED FOR THE FOUR TREATMENTS OF LASER THERAPY. AFTER 48 HOURS OF THE INITIAL TREATMENT, TOPICAL HYDROGEL WAS FOLLOWED. THE PATIENT WAS DISCHARGED WITH HOME CARE AND THE SKIN IRRITATION IS HEALED.
Patient problems: Fluid Discharge; Skin Discoloration
MAUDE report 17221150 ↗InjuryNov 29, 2022Patient-Device Incompatibility; Patient Device Interaction Problem; Patient-Device Incompatibility; Patient Device Interaction Problem
A HOSPITAL REPORTED AN INCIDENT INVOLVING A 62-YEAR-OLD MALE PATIENT. ON (B)(6) 2022, THE TEGADERM CHG DRESSING WAS USED TO SECURE THE PATIENT'S PICC (PERIPHERALLY INSERTED CENTRAL CATHETER) LINE LOCATED ON HIS BRACHIAL (DATE OF PICC LINE INSERTION WAS NOT REPORTED). THE AREA WAS CLEANSED WITH CHLOROPREP AND THE PICC LINE WAS STABILIZED WITH STAT-LOCK BEFORE THE DRESSING WAS PLACED. NO SKIN PROTECTANT WAS APPLIED ON THE AREA BEFORE THE DRESSING WAS PLACED. THE PATIENT RECEIVED IV FLUIDS AND OTHER UNSPECIFIED THERAPIES THROUGH THE PICC LINE. ON (B)(6) 2022, DURING AN OUTPATIENT VISIT FOR TREATMENT AND PICC LINE DRESSING CHANGE, THE DRESSING WAS NOTED WITH YELLOW DRAINAGE AND THE AREA WHERE THE CHLOROPREP WAS APPLIED FELT LIKE PITTING EDEMA. AFTER THE DRESSING WAS REMOVED, THE PATIENT'S SKIN WAS MOIST, WITH YELLOW PATCHES AND GRANULATION. THE AREA WAS TREATED WITH TOPICAL ANTIBIOTIC AND STEROID (CLOTRIMAZOLE/BACITRACIN/NEOMYCIN). THE ALLEGED INJURY RESOLVED AFTER ONE MONTH AND THE AREA IS SCARRED. THE PATIENT HAD NO PRE-EXISTING SKIN CONDITIONS AND THE DRESSING WAS APPLIED ON INTACT SKIN. NO ALLERGIES, MEDICAL HISTORY OR INTERVENTION REPORTED.
Patient problems: Skin Inflammation/ Irritation; Swelling/ Edema
MAUDE report 15882557 ↗InjuryDec 17, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A FACILITY IN (B)(6) REPORTED A (B)(6)-YEAR-OLD FEMALE WITH AN IJ CVC LINE FOR ANTIBIOTIC DELIVERY DEVELOPED SKIN LESIONS (DENUDATION AND MACERATION) WITH USE OF A 1657R 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I. V. SECUREMENT DRESSING. THE DRESSING WAS ON FOR MORE THAN 24 HOURS. MULTIPLE DRESSINGS HAD BEEN APPLIED. PRIOR TO DRESSING APPLICATIONS, CHLOROPREP/CHG AND CAVILON¿ NO STING BARRIER FILM WERE USED. THE LESIONS, PRESENTED UNDER THE CHG GEL PAD, WERE NOTICED BY HOSPITAL STAFF AFTER CLEANING OF THE SITE. THE PATIENT HAD NO PRIOR HISTORY OF SKIN CONDITIONS OR SENSITIVITY TO ADHESIVE. TEGADERM¿ CHG WAS DISCONTINUED, CATHETER WAS REMOVED, AND A NEW LINE WAS PLACED. THE SKIN REACTION HEALED.
Patient problems: Skin Irritation
MAUDE report 9485076 ↗InjuryDec 17, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A FACILITY IN (B)(6) REPORTED A (B)(6)-YEAR-OLD FEMALE WITH A IJ CVC LINE FOR ANTIBIOTIC DELIVER DEVELOPED SKIN LESIONS (ERYTHEMA AND PUSTULES) WITH USE OF A 1657R 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I. V. SECUREMENT DRESSING. THE DRESSING WAS ON FOR MORE THAN 7 DAYS. MULTIPLE DRESSINGS HAD BEEN APPLIED. PRIOR TO DRESSING APPLICATIONS, CHLOROPREP/CHG AND CAVILON¿ NO STING BARRIER FILM WERE USED. THE LESIONS PRESENTED UNDER THE CHG GEL PAD. THE PATIENT HAD NO PRIOR HISTORY OF SKIN CONDITIONS OR SENSITIVITY TO ADHESIVE. TEGADERM¿ CHG WAS DISCONTINUED, CATHETER WAS REMOVED, AND A NEW LINE WAS PLACED. THE SKIN REACTION HEALED.
Patient problems: Erythema; Skin Irritation
MAUDE report 9485012 ↗InjuryDec 17, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A FACILITY IN (B)(6) REPORTED AN (B)(6)-YEAR-OLD FEMALE WITH A CVC, BRACH PICC LINE FOR ANTIBIOTIC DELIVER DEVELOPED SKIN LESIONS WITH USE OF A TEGADERM¿ DRESSING, 1657R. THE DRESSING WAS ON FOR 7 DAYS. MULTIPLE DRESSINGS HAD BEEN APPLIED. PRIOR TO DRESSING APPLICATIONS, CHLOROPREP/CHG, CHLORHEXIDINE GLUCONATE AND CAVILON¿ NO STING BARRIER FILM WERE USED. THE CHG PLATE WAS REPORTEDLY ADHERED TO THE PATIENT'S SKIN PRIOR TO REMOVAL. THE FACILITY ALLEGED WHEN THE TEGADERM¿ DRESSING WAS REMOVED, SOME OF THE PATIENT'S SKIN CAME OFF. THE LESIONS PRESENTED UNDER THE CHG GEL PAD. THE PATIENT HAD NO PRIOR HISTORY OF SKIN CONDITIONS OR SENSITIVITY TO ADHESIVE. TEGADERM¿ CHG WAS DISCONTINUED, CATHETER WAS REMOVED, AND A NEW LINE WAS PLACED. THE SKIN REACTION HEALED.
Patient problems: Skin Irritation
MAUDE report 9477671 ↗InjurySep 26, 2019Patient Device Interaction Problem; Patient Device Interaction Problem
A NURSE ALLEGED THAT A MALE OUTPATIENT DEVELOPED A FUNGAL RASH/INFECTION ON THE LEFT INNER ARM UNDER A 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I.V. SECUREMENT DRESSING. THE DRESSING WAS USED TO PROTECT A BRACHIAL PICC LINE INSERTED FOR ANTIBIOTIC ADMINISTRATION. THE NURSE WAS UNSURE IF SKIN PREPARATION WAS CONDUCTED PRIOR TO DRESSING APPLICATION. THE RASH/INFECTION OCCURRED WITHIN 24 HOURS OF DRESSING APPLICATION. THE DRESSING WAS EXPOSED TO MOISTURE VIA DIAPHORESIS AND BATHING/SHOWERING DURING WEAR. THE CATHETER WAS STABILIZED WITH STAT-LOCK®. DIFLUCAN, ORAL, WAS PRESCRIBED FOR THE RASH. THE CATHETER REMAINED IN PLACE. THE PATIENT REPORTEDLY HAD NO PRE-EXISTING SKIN CONDITIONS OR ALLERGIES TO CHLORHEXIDINE GLUCONATE OR MEDICAL ADHESIVES.
Patient problems: Erythema; Fungal Infection
MAUDE report 9122425 ↗InjurySep 16, 2019Patient Device Interaction Problem; Patient Device Interaction Problem
A NURSE REPORTED THAT PUS, A SMALL BLISTER AND SLIGHT ARM PAIN OCCURRED WITH TWO 1657 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I.V. SECUREMENT DRESSING CHANGES FOR A PATIENT WHO HAD OPEN-HEART SURGERY. THE DRESSING WAS APPLIED TO PROTECT A PERIPHERALLY INSERTED CENTRAL CATHETER (PICC) (DOUBLE-LUMEN) IN THE UPPER RIGHT ARM. THE PICC LINE WAS IN PLACE IN THE ARM FOR 1.5 MONTHS PRIOR TO THE ALLEGED SYMPTOMS. THE SMALL BLISTER WAS NEAR THE PICC LINE INSERTION SITE. WITH EACH DRESSING CHANGE, THE SKIN WAS PREPPED WITH A CHLORHEXIDINE SWAB AND ALLOWED TO DRY BEFORE DRESSING APPLICATION. THE PICC LINE WAS REMOVED AND A NEW PERIPHERAL ACCESS LINE WAS PLACED. THE PATIENT WAS REPORTED TO HAVE NO FEVER, NO ELEVATED WHITE BLOOD CELL COUNT OR ANY SIGN OF INFECTION. THE PATIENT IS REPORTEDLY DOING WELL.
Patient problems: Injury; Irritation; Pain
MAUDE report 9072187 ↗InjurySep 12, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NURSE MANAGER REPORTED A PATIENT HAD A PORT NEEDLE SECURED WITH A 1665 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I. V. PORT DRESSING. THE PATIENT REPORTEDLY EXPERIENCED A PORT NEEDLE DISLODGEMENT WHEN THE PORT WAS ACCESSED IN THE ER. PATIENT SPECIFIC INFORMATION WAS NOT PROVIDED. NO FURTHER DETAILS WERE PROVIDED.
Patient problems: Reinfusion
MAUDE report 9009603 ↗InjuryJul 11, 2019Patient Device Interaction Problem; Patient Device Interaction Problem
A VASCULAR ACCESS NURSE SPECIALIST ALLEGED 3-4 OUTPATIENT PEDIATRIC PATIENTS (AGES AND GENDERS NOT SPECIFIED) EXPERIENCED IRRITATION AND/OR INFECTION RELATED TO THE USE OF 3M¿ TEGADERM¿ CHG I.V. SECUREMENT DRESSING. THE NURSE REPORTED ALL PATIENTS REQUIRED ADMISSION. SPECIFIC PATIENT TREATMENT DETAILS WERE NOT PROVIDED. A BIOPSY WAS PERFORMED FOR ONE FEMALE PATIENT WHERE FUNGUS MOLD AND (B)(6) WAS ALLEGEDLY GROWING AROUND THE DRESSING. THE NURSE INFORMED THIS ISSUE HAD BEEN NOTED IN THE SUMMER WHEN PATIENTS ARE OUT IN THE HEAT AND IN AND AROUND WATER. THE NURSE REPORTED AQUA GUARD IS SENT FOR PATIENTS TO USE FOR CENTRAL VENOUS LINES WHEN BATHING OR SHOWERING.
Patient problems: Skin Irritation; Unspecified Infection
MAUDE report 8781986 ↗InjuryMay 20, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NURSE REPORTED AN ADULT INPATIENT WAS RECEIVING A BLOOD INFUSION THROUGH THEIR IMPLANTED PORT CATHETER SITE. A 1665 TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I.V. PORT DRESSING WAS USED TO COVER AND SECURE THE PATIENT'S HUBER NEEDLE. THE HUBER NEEDLE REPORTEDLY BECAME DISLODGED AND THE PATIENT EXPERIENCED AN INFILTRATION OF THE BLOOD INFUSION UNDER THEIR SKIN AT THE PORT SITE. A PERIPHERAL IV SITE WAS USED FOR IV ACCESS WHILE THE IMPLANTED PORT SITE HEALED.
Patient problems: Infiltration into Tissue
MAUDE report 8623240 ↗InjuryFeb 7, 2019Improper or Incorrect Procedure or Method; Patient Device Interaction Problem; Improper or Incorrect Procedure or Method; Patient Device Interaction Problem
A NURSE REPORTED AN INPATIENT WITH TOXIC EPIDERMAL NECROLYSIS HAD A LEFT INTERNAL JUGULAR (IJ) CATHETER IN PLACE DUE TO LIMITED VENOUS ACCESS. THE NURSE REPORTED ONE 1657 3M¿ TEGADERM CHG DRESSING WAS APPLIED TO THE SITE. THE SKIN AROUND THE INSERTION SITE WAS "NOT HEALTHY OR INTACT" PRIOR TO APPLICATION OF THE TEGADERM CHG DRESSING. THE NURSE REPORTED BIOPATCH HAD BEEN APPLIED TO THE SITE PRIOR TO APPLICATION OF THE TEGADERM CHG DRESSING. THE NURSE REPORTED THE PATIENT EXPERIENCED SKIN NECROSIS AROUND THE CATHETER INSERTION SITE AND THE PATIENT WILL REQUIRE SKIN GRAFTING.
Patient problems: Necrosis
MAUDE report 8316954 ↗InjuryJan 24, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NURSE REPORTED HOSPITALIZED ONCOLOGY PATIENTS WERE RECEIVING CHEMOTHERAPY INFUSIONS THROUGH AN IMPLANTED PORT. THE IMPLANTED PORTS WERE ACCESSED WITH A HUBER NEEDLE AND WERE ALLEGEDLY SECURED WITH A 1665 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I. V. PORT DRESSING. THE NURSE REPORTED SIX PATIENTS EXPERIENCED HUBER NEEDLE DISLODGEMENTS IN THE PAST YEAR. THE PATIENTS REQUIRED REINSERTION OF THEIR HUBER NEEDLES. THE NURSE REPORTED NO OTHER PATIENT CONSEQUENCE/INJURY WAS ASSOCIATED WITH THESE DISLODGEMENTS.
Patient problems: Reinfusion
MAUDE report 8273698 ↗InjuryJan 24, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A NURSE REPORTED A HOSPITALIZED ONCOLOGY PATIENT WAS RECEIVING A CHEMOTHERAPY INFUSION THROUGH AN IMPLANTED PORT. THE IMPLANTED PORT WAS ACCESSED WITH A HUBER NEEDLE AND WAS ALLEGEDLY SECURED WITH A 1665 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I. V. PORT DRESSING. THE NURSE REPORTED THE HUBER NEEDLE BECAME DISLODGED AND THE CHEMOTHERAPY MEDICATION LEAKED ONTO THE PATIENT'S SKIN. THE PATIENT EXPERIENCED A SKIN INJURY THAT RESEMBLED CELLULITIS. THE PATIENT WAS TREATED WITH IV ANTIBIOTICS. THE IMPLANTED PORT CATHETER COULD NOT BE USED. THE PATIENT REQUIRED AN INSERTION OF A PICC LINE TO RESUME THERAPY.
Patient problems: Cellulitis
MAUDE report 8273683 ↗InjuryJan 17, 2019Improper or Incorrect Procedure or Method; Adverse Event Without Identified Device or Use Problem; Improper or Incorrect Procedure or Method; Adverse Event Without Identified Device or Use Problem
A HOSPITAL REPORTED FOUR PEDIATRIC PATIENTS EXPERIENCED DISLODGEMENT OF THEIR NEWLY INSERTED TUNNELED CENTRAL CATHETERS. 1660 3M¿ TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I.V. SECUREMENT DRESSINGS WERE REPORTEDLY APPLIED TO THE CATHETER SITES. THE TUNNELED CENTRAL CATHETER CUFFS WERE NOTED TO BE EXPOSED WHEN THE DRESSINGS WERE REMOVED. NO INDIVIDUAL PATIENT INFORMATION WAS AVAILABLE. AT LEAST TWO OF THE PATIENTS REQUIRED REINSERTION OF THEIR TUNNELED CENTRAL CATHETERS.
Patient problems: No Code Available
MAUDE report 8256951 ↗InjuryJan 17, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A PHYSICIAN ALLEGED 1877-2100 3M¿ PICC/CVC SECUREMENT DEVICE + TEGADERM¿ CHG CHLORHEXIDINE GLUCONATE I.V. SECUREMENT DRESSING DID NOT SECURE AN IJ (INTERNAL JUGULAR) CATHETER PROPERLY AND A PATIENT LOST HIS LINE IN THE ICU". THE PATIENT REPORTEDLY REQUIRED REINSERTION OF THEIR CENTRAL CATHETER.
Patient problems: No Code Available
MAUDE report 8256394 ↗
Other 3m Company products
- Steri-Drape11 models · 7 reports · 8 recalls
- 3M Attest5 models · 1 reports · 4 recalls
- 3M Steri-Drape4 models · 0 reports · 4 recalls
- Ranger10 models · 176 reports
- 3M Ranger3 models · 73 reports · 1 recall
- Attest2 models · 0 reports · 2 recalls
- 3M Red Dot8 models · 16 reports · 1 recall
- Fast Release Varnish2 models · 2 reports · 1 recall
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page