TheraSphere Administration SetRecalls & reported problems across all models
Biocompatibles Uk Ltd · 2 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
3 open recalls name at least one TheraSphere Administration Set model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls
- 3
We found 2 models of TheraSphere Administration Set by Biocompatibles Uk Ltd in the FDA's device registry (GUDID). Together they are named in 5 adverse event reports in the FDA's MAUDE database, received between Dec 2, 2020 and Aug 12, 2025 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Radiation Underexposure” (3 reports).
3 FDA recall records name at least one of these models by its device identifier, 3 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
TheraSphere Administration Set recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Sep 26, 2023Open, Classified
Devices may leak as a result of a manufacturing issue. Leakage may result in a delay of therapy, increase risk of bloodstream infection (BSI), and may expose both patients and healthcare workers to hazardous medication. There is also the potential for life-threatening situations to occur requiring additional medical intervention.
Z-0133-2024 · Root cause: Process control · Recall details · FDA record ↗
- Jul 23, 2021Open, Classified
Potential for leaks and loosening at the patient catheter connection
Z-2328-2021 · Root cause: Component change control · Recall details · FDA record ↗
- Jul 23, 2021Open, Classified
Potential for leaks and loosening at the patient catheter connection
Z-2327-2021 · Root cause: Component change control · Recall details · FDA record ↗
Most reported TheraSphere Administration Set problems
Device problems
- Radiation Underexposure3
- Detachment of Device or Device Component2
- Device Contamination with Chemical or Other Material2
- Adverse Event Without Identified Device or Use Problem1
- Contamination1
- Infusion or Flow Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Vascular Dissection1
TheraSphere Administration Set models
2 models, most reported first. Each model has its own page with its reports, recalls and device details.
- TheraSphere Administration Set OTT-SPE-FP-001Microspheres Radionuclide2 recalls2 reports
- TheraSphere Administration Set 990226.SPEMicrospheres Radionuclide1 recall3 reports
Recent TheraSphere Administration Set adverse event reports
The 5 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionAug 12, 2025Contamination; Device Contamination with Chemical or Other Material; Radiation Underexposure; Contamination; Device Contamination with Chemical or Other Material; Radiation Underexposure
IT WAS REPORTED THAT FOREIGN MATERIAL WAS OBSERVED IN THE TUBING. TWO THERASPHERE ADMINISTRATION SETS WERE SELECTED FOR USE IN THE DELIVERY OF 6.5GBQ AND 10.5 GBQ THERASPHERE DOSE VIALS IN A Y-90 PROCEDURE. DURING THE FIRST ADMINISTRATION, ALL THE PROPER STEPS WERE FOLLOWED OFF THE CHECKLIST; HOWEVER, WHEN INJECTING, THE PRESSURE VIAL IMMEDIATELY STARTED TO FILL AND A BROWN GLOB WAS OBSERVED WORKING ITS WAY THROUGH THE TUBING. THE PHYSICIAN CONTINUED FLUSHING UNTIL THE RADOS DOSIMETER REACHED 0.0 MR/H. BEFORE INJECTING THE SECOND DOSE INTO ANOTHER SEGMENT OF THE LIVER, THE NON-BOSTON SCIENTIFIC MICROCATHETER WAS CHECKED FOR KINKS, BUT NONE WERE OBSERVED. THE CHECKLIST WAS FOLLOWED AGAIN FOR THE SECOND DOSE ADMINISTRATION, BUT THE SAME THING HAPPENED; HOWEVER, THIS TIME A GRAY/BLACK SPECK WAS OBSERVED WORKING ITS WAY THROUGH THE TUBING. THERE WAS A CLOUDY RESIDUE IN THE TUBING AFTER EACH ADMINISTRATION, NEAR THE NEEDLE INJECTOR. THERE WAS A LOW PERCENT DELIVERY OF 86% FOR BOTH DOSES. THE PROCEDURE WAS COMPLETED WITH THESE DEVICES. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22787426 ↗MalfunctionAug 12, 2025Device Contamination with Chemical or Other Material; Radiation Underexposure; Device Contamination with Chemical or Other Material; Radiation Underexposure
IT WAS REPORTED THAT FOREIGN MATERIAL WAS OBSERVED IN THE TUBING. TWO THERASPHERE ADMINISTRATION SETS WERE SELECTED FOR USE IN THE DELIVERY OF 6.5GBQ AND 10.5 GBQ THERASPHERE DOSE VIALS IN A Y-90 PROCEDURE. DURING THE FIRST ADMINISTRATION, ALL THE PROPER STEPS WERE FOLLOWED OFF THE CHECKLIST; HOWEVER, WHEN INJECTING, THE PRESSURE VIAL IMMEDIATELY STARTED TO FILL AND A BROWN GLOB WAS OBSERVED WORKING ITS WAY THROUGH THE TUBING. THE PHYSICIAN CONTINUED FLUSHING UNTIL THE RADOS DOSIMETER REACHED 0.0 MR/H. BEFORE INJECTING THE SECOND DOSE INTO ANOTHER SEGMENT OF THE LIVER, THE NON-BOSTON SCIENTIFIC MICROCATHETER WAS CHECKED FOR KINKS, BUT NONE WERE OBSERVED. THE CHECKLIST WAS FOLLOWED AGAIN FOR THE SECOND DOSE ADMINISTRATION, BUT THE SAME THING HAPPENED; HOWEVER, THIS TIME A GRAY/BLACK SPECK WAS OBSERVED WORKING ITS WAY THROUGH THE TUBING. THERE WAS A CLOUDY RESIDUE IN THE TUBING AFTER EACH ADMINISTRATION, NEAR THE NEEDLE INJECTOR. THERE WAS A LOW PERCENT DELIVERY OF 86% FOR BOTH DOSES. THE PROCEDURE WAS COMPLETED WITH THESE DEVICES. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22787425 ↗MalfunctionOct 20, 2021Infusion or Flow Problem; Adverse Event Without Identified Device or Use Problem; Radiation Underexposure; Infusion or Flow Problem; Adverse Event Without Identified Device or Use Problem; Radiation Underexposure
IT WAS REPORTED THAT A PROCEDURAL RELATED DISSECTION OCCURRED. IN (B)(6) 2020, A MISADMINISTRATION OF THERASPHERE Y-90 MICROSPHERES OCCURRED. THE PHYSICIAN WAS UNABLE TO INJECT THE THERASPHERE FROM THE DELIVERY APPARATUS INTO THE PATIENT. SEVEN DAYS LATER, A REPEAT PROCEDURE WAS ATTEMPTED, HOWEVER, THE INJECTION ATTEMPT FAILED. DURING THIS PROCEDURE, STENOSIS IN THE FEMORAL ARTERY WAS IDENTIFIED. THE PATIENT WAS GIVEN BLOOD THINNERS. THE STENOSIS IS THOUGHT TO BE EITHER THE DISSECTION OF THE ARTERIAL WALL FROM THE NON-BSC CLOSURE DEVICE, OR IT WAS THE DISPLACED CLOSURE DEVICE ITSELF FROM THE FIRST THERASPHERE PROCEDURE. IN LATE (B)(6) 2020, THE PATIENT REPORTED DIFFICULTY IN WALKING, THEIR LEG WOULD GO NUMB AND ESSENTIALLY FEEL DEAD AND HEAVY. THE PATIENT SOUGHT MEDICAL ADVICE. AFTER IMAGING OF THE ARTERY WAS COMPLETED, THE PATIENT LEARNED THAT THE CLOSURE DEVICE HAD COLLAPSED INTO THE ARTERY AND THE ARTERIAL WALL SUFFERED A DISSECTION. IN (B)(6) 2021, A SURGEON WHO SPECIALIZES IN ARTERIAL SURGERY ATTEMPTED TO REPAIR THE DISSECTED ARTERIAL WALL AND REMOVE THE COLLAPSED ANGIOSEAL DEVICE, HOWEVER, THE PATIENT STILL EXPERIENCES LEG NUMBNESS.
Patient problems: No Clinical Signs, Symptoms or Conditions; Vascular Dissection
MAUDE report 12668230 ↗MalfunctionDec 8, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
THE TREATING PHYSICIAN REPORTED THAT TWO ADMINISTRATION SETS WERE PERSISTENTLY UNWINDING AT THE CONNECTION SITE BETWEEN THE MICROCATHETER AND THE ADMINISTRATION SET DURING A PATIENT CASE. NO LEAKAGE OR CONTAMINATION OF MICROSPHERES OUTSIDE THE ADMINISTRATION SET AND CATHETER WAS REPORTED. THE USER RE-TIGHTENED THE CONNECTION, AND ALLOWED THE TUBING TO RELAX TO TEST THE CONNECTION. THIS WAS REPEATED UNTIL NO MOVEMENT WAS OBSERVED AT THE CONNECTION SITE. THE TUBING WAS NOTED TO RETAIN SOME OF THE TORQUE MEMORY TO OVERCOME THE TIGHTENED CONNECTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10972532 ↗MalfunctionDec 2, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
THE TREATING PHYSICIAN REPORTED THAT A MICROCATHETER PERSISTENTLY DETACHED FROM THE ADMINISTRATION SET DURING A PATIENT CASE, RESULTING IN A MAJOR SPILL OF THERASPHERE MICROSPHERES AT THE SITE OF CONNECTION BETWEEN THE THERASPHERE ADMINISTRATION SET AND THE MICROCATHETER. THE SPILL CONTAMINATED THE DRAPE, TOWELS, FLOOR AND SURROUNDING AREA OF THE OPERATING ROOM. THE SPILL REACHED THE SHOES OF THE ATTENDING STAFF, AS WELL AS THE GLOVES OF THE TREATING PHYSICIAN. THE TREATING OPERATING ROOM WAS SHUT DOWN FOR THE REMAINDER OF THE DAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10932400 ↗
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.