ThoracoportRecalls & reported problems across all models
Covidien LP · 7 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 59
- Deaths reported
- 0
- Injuries reported
- 7
- Recalls
- 0
We found 7 models of Thoracoport by Covidien LP in the FDA's device registry (GUDID). Together they are named in 59 adverse event reports in the FDA's MAUDE database, received between Apr 17, 2017 and Apr 19, 2026 — classified as 7 injuries, 52 malfunctions.
The most frequently reported specific device problem is “Break” (29 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported Thoracoport problems
Device problems
- Break29
- Detachment of Device or Device Component16
- Packaging Problem14
- Product Quality Problem8
- Detachment Of Device Component5
- Difficult to Insert4
- Material Split, Cut or Torn4
- Environmental Particulates3
Patient problems
- No Clinical Signs, Symptoms or Conditions29
- No Known Impact Or Consequence To Patient12
- No Consequences Or Impact To Patient8
- Device Embedded In Tissue or Plaque5
- No Patient Involvement3
- No Information1
- Tissue Breakdown1
- Tissue Damage1
Thoracoport models
7 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Thoracoport 179301Laparoscope, general & plastic surgery14 reports
- Thoracoport 179303Laparoscope, general & plastic surgery13 reports
- Thoracoport 179305Laparoscope, general & plastic surgery9 reports
- Thoracoport 179309Laparoscope, general & plastic surgery8 reports
- Thoracoport 179307Laparoscope, general & plastic surgery5 reports
- Thoracoport 179308Laparoscope, general & plastic surgery5 reports
- Thoracoport 179310Laparoscope, general & plastic surgery5 reports
Recent Thoracoport adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionApr 19, 2026Difficult to Insert; Noise, Audible
IT WAS REPORTED THAT PREOPERATIVELY, THERE WAS AN ABNORMAL SOUND FROM THE DEVICE. ADDITIONALLY, THERE WAS DIFFICULTY INSERTING A DEVICE TO THE PORT. TO RESOLVE THE ISSUE, A NEW DEVICE WAS USED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24921427 ↗MalfunctionDec 16, 2025Break; Product Quality Problem; Break; Product Quality Problem
IT WAS REPORTED THAT PRE-OPERATIVELY, THE CANNULA BROKE AND THERE WAS AN OIL STAIN-LIKE SUBSTANCE. ANOTHER DEVICE WAS REPLACED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23822733 ↗InjuryDec 8, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, AT THE END OF THE PROCEDURE, ONCE THE INCISION WAS ALMOST CLOSED, IT WAS NOTICED THAT THE TROCAR WAS NOT INTACT. A FRAGMENT HAD BROKEN OFF AND FALLEN INTO THE CHEST OF THE PATIENT. IT WAS THEREFORE NECESSARY TO REOPEN THE PATIENT TO RETRIEVE THE FRAGMENT. EXTENSION OF SURGERY WAS DONE IN ORDER TO RETRIEVE THE LOST FRAGMENT INSIDE THE THORAX.
Patient problems: Tissue Breakdown
MAUDE report 23752720 ↗MalfunctionDec 3, 2025Detachment of Device or Device Component; Material Split, Cut or Torn; Detachment of Device or Device Component; Material Split, Cut or Torn
ACCORDING TO THE REPORTER DURING A THORACOSCOPY PROCEDURE, THE LOWER PART OF THE SLEEVE HAD TORN OFF. NO COMPONENT FELL INTO THE PATIENT'S ABDOMINAL CAVITY. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23702940 ↗MalfunctionNov 19, 2025Break; Break
IT WAS REPORTED THAT DURING A LAPAROSCOPIC BYPASS PROCEDURE, THE TROCAR BROKE WHILE BEING INTRODUCED INTO THE PATIENT¿S THORAX, RESULTING IN PLASTIC DEBRIS SHATTERING INSIDE THE THORAX. THE PLASTIC DEBRIS FELL INTO THE PATIENT¿S THORAX AND REQUIRED RETRIEVAL BY THE SURGEON. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23595343 ↗MalfunctionSep 10, 2025Break; Difficult to Insert; Break; Difficult to Insert
ACCORDING TO THE REPORTER, DURING A THORACOSCOPIC PARTIAL RESECTION OF THE RIGHT UPPER LOBE, AT THE TIME OF PORT PLACEMENT, WHEN IT WAS REMOVED AND INSERTED, THERE WAS CATCH (DIFFICULT TO INSERT). IT WAS ALSO NOTED THAT THE CANNULA BROKE. A NEW PORT WAS PROVIDED AND USED TO RESOLVE THE ISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23015137 ↗MalfunctionAug 6, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, PRE-OPERATIVELY, PART OF THE PRODUCT WAS MISSING WHEN IT WAS OPENED. THE CANNULA BROKE AND DISENGAGED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22734386 ↗MalfunctionFeb 21, 2025Break; Product Quality Problem; Break; Product Quality Problem
ACCORDING TO THE REPORTER, PRIOR TO USE, THE OBTURATOR/TROCAR BROKE. ADDITIONALLY, CLEAR LIQUID WAS ADHERED TO THE CANNULA PORTION OF THE 5 TROCARS. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21439409 ↗MalfunctionFeb 21, 2025Break; Product Quality Problem; Break; Product Quality Problem
ACCORDING TO THE REPORTER, PRIOR TO USE, THE OBTURATOR OR TROCAR BROKE. ADDITIONALLY, CLEAR LIQUID WAS ADHERED TO THE CANNULA PORTION OF THE FIVE TROCARS. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21439262 ↗MalfunctionFeb 21, 2025Break; Product Quality Problem; Break; Product Quality Problem
ACCORDING TO THE REPORTER, PRIOR TO USE, THE OBTURATOR OR TROCAR BROKE. ADDITIONALLY, CLEAR LIQUID WAS ADHERED TO THE CANNULA PORTION OF THE FIVE TROCARS. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21439228 ↗MalfunctionFeb 21, 2025Break; Product Quality Problem; Break; Product Quality Problem
ACCORDING TO THE REPORTER, PRIOR TO USE, THE OBTURATOR OR TROCAR BROKE. ADDITIONALLY, CLEAR LIQUID WAS ADHERED TO THE CANNULA PORTION OF THE FIVE TROCARS. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21438805 ↗MalfunctionFeb 21, 2025Break; Product Quality Problem; Break; Product Quality Problem
ACCORDING TO THE REPORTER, PRIOR TO USE, THE OBTURATOR OR TROCAR BROKE. ADDITIONALLY, CLEAR LIQUID WAS ADHERED TO THE CANNULA PORTION OF THE FIVE TROCARS. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21437719 ↗MalfunctionFeb 13, 2025Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, DURING A OPEN THORACIC SURGERY, THE END OF THE TROCAR SHEATH BROKE IN THE PATIENT'S CHEST. THE MISSING PIECE WAS FOUND AT THE BOTTOM OF THE PATIENT'S CHEST. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21378772 ↗MalfunctionNov 11, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, PREOPERATIVELY, THE SEAL WAS DISCONNECTED. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20651575 ↗MalfunctionSep 26, 2024Break; Break
ACCORDING TO THE REPORTER, INTRA-OPERATIVELY, WHILE USING THE DEVICE, THE TIP OF THE PORT BROKE. ANOTHER DEVICE WAS USED TO COMPLETE THE CASE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20311991 ↗
Other Covidien LP products
- Endo GIA48 models · 26,277 reports · 8 recalls
- Endo GIA Ultra3 models · 15,650 reports
- Shiley387 models · 9,392 reports · 5 recalls
- Signia16 models · 8,201 reports · 6 recalls
- LigaSure32 models · 7,283 reports · 1 recall
- Tri-Staple 2.037 models · 4,892 reports · 2 recalls
- Polysorb291 models · 4,564 reports · 2 recalls
- EEA39 models · 4,432 reports · 1 recall
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page