TRANSCENDRecalls & reported problems across all models
Microport Orthopedics Inc. · 9 models in the FDA device registry
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 37
- Deaths reported
- 0
- Injuries reported
- 37
- Recalls
- 0
We found 9 models of TRANSCEND by Microport Orthopedics Inc. in the FDA's device registry (GUDID). Together they are named in 37 adverse event reports in the FDA's MAUDE database, received between May 20, 2019 and Sep 8, 2025 — classified as 37 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (11 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported TRANSCEND problems
Device problems
- Insufficient Device Problem Information11
- Device Dislodged or Dislocated7
- Detachment of Device or Device Component4
- Appropriate Device Problem Term/Code Not Available3
- Material Disintegration3
- Corroded2
- Naturally Worn2
- Noise, Audible2
Patient problems
- Metal Related Pathology11
- Pain7
- No Information6
- Unspecified Infection6
- Insufficient Information5
- Reaction4
- Failure of Implant1
- Joint Dislocation1
TRANSCEND models
9 models, most reported first. Each model has its own page with its reports, recalls and device details.
- TRANSCEND® 26000026Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)10 reports
- TRANSCEND® 26000022Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)5 reports
- TRANSCEND® 26000025Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)5 reports
- TRANSCEND® 26000017Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented4 reports
- TRANSCEND® 26000027Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)4 reports
- TRANSCEND® 26000023Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)3 reports
- TRANSCEND® 26000018Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)2 reports
- TRANSCEND® 26000020Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)2 reports
- TRANSCEND® 26000028Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)2 reports
Recent TRANSCEND adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
InjurySep 8, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, PATIENT WAS REVISED DUE TO INFECTION. SRNJR NUMBER: (B)(6). SIDE: L. GENDER: F. OTHER LEGAL MANUFACTURER: PRODUCT ID: 6310-60-36 LONGEVITY UHMW POLYETHYLENE LINER 60MMX36MM ELEV RIM 10 DEG ZIMMER BIOMET.
Patient problems: Unspecified Infection
MAUDE report 22999146 ↗InjuryOct 3, 2024Corroded; Corroded
ALLEGEDLY, PATIENT UNDERWENT REVISION SURGERY ON RIGHT HIP DUE TO PAIN FROM UNDERLYING MECHANICAL ASSISTED CREVICE CORROSION FROM MODULAR, COBALT CHROME RIGHT HIP REPLACEMENT WITH AN ELEVATED COBALT LEVELS AND EVIDENCE OF PSEUDOTUMOR ON MRI AND METALLOSIS. THE PRESENCE OF A BLACK RESIDUE PREDOMINANTLY AT THE NECK BODY JUNCTION THAN THE HEAD NECK JUNCTION WAS NOTICED. NON MPO PRODUCTS: ZIMMER BIOMET RB 50 MM ACETABULAR COMPONENT, 50/36 POLYLINER, 25 MM ACETABULAR SCREW.
Patient problems: Metal Related Pathology; Pain
MAUDE report 20361185 ↗InjuryAug 20, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
ALLEGEDLY, HIP REVISED FOR RECURRENT DISLOCATION.
Patient problems: Insufficient Information
MAUDE report 20002397 ↗InjuryJun 26, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
ALLEGEDLY, PATIENT WAS REVISED DUE TO DISLOCATION/SUBLUXATION/INFECTION/ADVERSE SOFT TISSUE REACTION TO PARTICULATE DEBRIS. SRNJR NUMBER: 5116346. SIDE: R. GENDER: M. NON REVISED PRODUCTS: PRODUCT ID: PPW39122 PROFEMUR® R HA COATED PROX BODY SMALL V4/ LOT. NO: 127487759/ QTY: 1. PRODUCT ID: PPW38000 PROFEMUR® 135MM STEM STRAIGHT/TAPER SIZE 10/ LOT. NO: U0266735/ QTY: 1.
Patient problems: Metal Related Pathology; Unspecified Infection
MAUDE report 19614647 ↗InjuryJun 21, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, PATIENT WAS REVISED DUE TO ADVERSE SOFT TISSUE REACTION TO PARTICULATE DEBRIS. SRNJR NUMBER: (B)(4) SIDE: L GENDER: F NON MPO DEVICES: 99961735 ZMR CONE A BODY PROXIMAL STEM LENGTH 80MM 40X35MM NECK AND 99821713 TAPER STEM 17MM X 135MM (ZIMMER BIOMET)
Patient problems: Metal Related Pathology
MAUDE report 19586738 ↗InjuryJun 21, 2024Use of Device Problem; Use of Device Problem
ALLEGEDLY, PATIENT WAS REVISED DUE TO HEAD/SOCKET MISMATCH - SOCKET. SRNJR NUMBER: (B)(6). SIDE: L. GENDER: M. NON MPO DEVICES: 121712064 PINN SECTOR HA ACET CUP 64MM, 121936164 PINNACLE MARATHON PE LINER +4 10 DEGREE 64X36MM AND 121730500 PINNACLE 6.5 CANCELLOUS SCREW 30MM (DEPUY).
Patient problems: Insufficient Information
MAUDE report 19586530 ↗InjuryMay 3, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, METALLOSIS AND ASEPTIC CUP LOOSENING.
Patient problems: Metal Related Pathology
MAUDE report 19243564 ↗InjuryFeb 27, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, UNEXPLAINED PAIN. SIDE: R. REVISION NJR: (B)(6). GENDER: F, EXPLANTED: FEMORAL STEM, ACETABULAR CUP.
Patient problems: Pain
MAUDE report 18792158 ↗InjuryFeb 12, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, REVISION DONE DUE TO PAINFUL HIP. THEY TOOK OUT THE STEM, NECK, HEAD AND POLY. THEY REPLACE THE POLY. PRODUCTS NO REVISE: PRODUCT: DSBFGD52 DYNASTY® BF SHELL 52MM GROUP D, LOT: 1502022, QTY: 1.
Patient problems: Pain
MAUDE report 18687000 ↗InjuryNov 23, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, PATIENT UNDERWENT L THR ON (B)(6) 2022. REVISED ON (B)(6) 2023 DUE TO INFECTION. FEMORAL HEAD AND LINER REPLACED. AUSTRALIA (B)(4).
Patient problems: Unspecified Infection
MAUDE report 18199221 ↗InjurySep 13, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, PT UNDERWENT L THR ON (B)(6) 2019. REVISED ON (B)(6) 2023 DUE TO A SUSPECTED LOW GRADE INFECTION. THE FEMORAL HEAD AND ACETABULAR LINER WERE REVISED TO ALLOW WASH OUT OF THE ACETABULAR SHELL AND STEM SURFACES. AUSTRALIA (B)(4).
Patient problems: Unspecified Infection
MAUDE report 17739815 ↗InjuryJun 1, 2023Noise, Audible; Noise, Audible
ALLEGEDLY, THE PATIENT HAD A REVISION SURGERY 2 DAYS BEFORE. THE PATIENT IS COMPLAINING OF CLICKING OF THE RIGHT HIP. IT WAS FELT SHE MAY HAVE SOME METAL IMPINGING IN THE HIP AND IT WAS FELT SHE WOULD BENEFIT FROM REVISION IN ORDER TO DECREASE THE CLICKING, DECREASE RISK OF DISLOCATION AND INCREASE THE LONGEVITY OF THE PROSTHESIS. OPERATIVE FINDINGS: WHEN THE HIP WAS EXTENDED AND EXTERNALLY ROTATED, THE METAL BODY OF THE PROFERNUR R DID STRIKE THE POSTERIOR RIM OF THE SHELL. IT MADE A CLICKING NOISE BUT DID NOT DISLOCATE THE BALL BECAUSE OF LARGE DISTANCE. DECREASED OFFSET WITH METAL BODY IMPINGING ON THE METAL SHELL. NON REVISED PRODUCTS: PRODUCT ID: SPHS8000 PROFEMUR® R 135MM.STEM SIZE 10 MTS.FINISH STRAIGHT/TAPER/ LOT NO.: 07493194/ QTY: 1. NON MPO PRODUCTS: STRYKER MDM 58-MRN, 58 / 46 METAL LINER, 46-MRN POLY BALL, 30-MRN ACETABULAR SCREWS & 35-MRN ACETABULAR SCREWS.
Patient problems: Loss of Range of Motion
MAUDE report 17043482 ↗InjuryMar 17, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
ALLEGEDLY, PATIENT UNDERWENT IN (B)(6) 2010 REPLACEMENT OF THE RIGHT HIP BY MEANS OF A METAL-METAL PROSTHESIS IMPLANTATION, HAS DEVELOPED PSEUDO-TUMOR FROM METAL-METAL COUPLING, WITH EVIDENCE OF A COBALT DOSAGE OF 7.7 MG / L (COMPARED TO REFERENCE <1.0MG / L), CAUSING ASEPTIC LOOSENING OF THE PROSTHESIS AND FORCING IT TO UNDERGO A PROSTHETIC REVISION IN 2014, OF INCREASED COMPLEXITY DUE TO THE PRESENCE OF THE TUMOR MASS. MORE TOOLS SINCE THE ONSET OF METALLOSIS AND, EVEN MORE SO, THE DEVELOPMENT OF PSEUDO-TUMOR REPRESENT CLEAR TYPICAL CONSEQUENCES OF METAL-METAL COMBINATIONS. ADDITIONAL INFORMATION RECEIVED ON 12/13/2022: ALLEGEDLY, REPORTED THE ONSET OF LOW-GRADE FEVER, INFECTIOUS CAUSES EXCLUDED. REPORTED GROIN PAIN WITH POAS WEAKNESS FOR ABOUT 1 YEAR. A CLINICAL ANALYSIS WITH ACCEPTANCE DATE OF (B)(6) 2014 SHOWS RESULTS OF P-CHROME 0.4 UG/L AND SG-COBALT 7.7UG/L. CLINICAL RECORDS SHOWED THAT THE DATE OF THE INTERVENTION FOR REVISION SURGERY WAS ON (B)(6) 2014. A MUSCLE-TENDON ULTRASOUND WITH DATE OF (B)(6) 2014 FOR THE RIGHT HIP, A CT PELVIS/SACROILIAC WITH DATE OF (B)(6) 2014 FOR THE RIGHT HIP AND OTHER STUDIES ARE FOUND FROM PAGES NUMBER 71 TO 77 IN THE FILE "DOC. 05 CARTELLA
Patient problems: Metal Related Pathology; Pain
MAUDE report 16565555 ↗InjuryAug 11, 2022Adverse Event Without Identified Device or Use Problem
ALLEGEDLY, PATIENT UNDERWENT LEFT THR ON (B)(6) 2022. REVISED ON (B)(6) 2022 DUE TO INFECTION. PERFORMED WASHOUT AND CHANGE OF LINER AND FEMORAL HEAD. SURGICAL SPECIALTIES REF (B)(4).
Patient problems: Unspecified Infection
MAUDE report 15212380 ↗InjuryJun 24, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated
ALLEGEDLY, REVISION WAS PERFORMED FOR A CASE OF PROLAPSE. THE BIPOLAR CUP SIDE WAS DAMAGED BEFORE REVISION, CAUSING THE PATIENT'S PROLAPSE. DOCTOR'S FINDING: THE BIPOLAR CUP SIDE WAS DAMAGED (RING DEFORMATION) BEFORE THE REVISION, WHICH MAY HAVE CAUSED THE PATIENT'S PROLAPSE. REPORTING PARTY'S FINDINGS AND RESPONSE: THE RING IN THE OUTER CUP WAS DEFORMED AND SEEMED TO BE LOOSE, SO THE CUP AND HEAD WERE REPLACED. JAPAN - (B)(4).
Patient problems: Prolapse
MAUDE report 14800107 ↗
Other Microport Orthopedics Inc. products
All Microport Orthopedics Inc. devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page