VitalRecalls & reported problems across all models
Biomet Spine LLC · 30 models in the FDA device registry
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 12
- Deaths reported
- 0
- Injuries reported
- 10
- Recalls
- 24
We found 30 models of Vital by Biomet Spine LLC in the FDA's device registry (GUDID). Together they are named in 12 adverse event reports in the FDA's MAUDE database, received between Sep 14, 2021 and Oct 17, 2024 — classified as 10 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Fracture” (6 reports).
24 FDA recall records name at least one of these models by its device identifier.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Vital recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2234-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2232-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2231-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2230-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2229-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2228-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2227-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2226-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2225-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2224-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2223-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2222-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2221-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2220-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2219-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2218-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2217-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2216-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2215-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2214-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2213-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2212-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2211-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- May 5, 2020Class IITerminated
There are reports of inadequate locking of the extended tab screws. Complaints were reported where the closure top backed out of the screw post-operatively.
Z-2210-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported Vital problems
Device problems
- Fracture6
- Material Twisted/Bent4
- Loosening of Implant Not Related to Bone-Ingrowth1
- Material Deformation1
Patient problems
- Insufficient Information6
- Foreign Body In Patient3
- Malunion of Bone3
- No Clinical Signs, Symptoms or Conditions2
- Failure of Implant1
Vital models
30 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Vital™ 810M4530Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M4535Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M4540Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M4545Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M5535Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M5540Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M5545Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M5550Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M5555Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M6535Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M6540Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M6545Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M6550Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M6555Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M7535Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M7540Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M7545Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M7550Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 810M7555Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 811M8540Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 811M8545Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 811M8550Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 811M8555Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 811M8560Thoracolumbosacral pedicle screw system1 recall0 reports
- Vital™ 801M4545Thoracolumbosacral pedicle screw system6 reports
- Vital™ 801M5545Thoracolumbosacral pedicle screw system2 reports
- Vital™ 801M5540Thoracolumbosacral pedicle screw system1 report
- Vital™ 850M0022Screwdriver1 report
- Vital™ 850M0025Screwdriver1 report
- Vital™ 805M8570Thoracolumbosacral pedicle screw system1 report
Recent Vital adverse event reports
The 12 most recent reports across all models, in the reporter's own words as published by the FDA.
InjuryOct 17, 2024Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED TO ADDRESS SIX VITALITY CLOSURE TOPS THAT MIGRATED OUT OF THEIR MATING BONE SCREWS POST-OPERATIVELY. THE PATIENT HAD RECEIVED A T10-S2 POSTERIOR LUMBAR FUSION, AND THE CLOSURE TOPS POPPED OFF AT L5 TO S2. THE PATIENT CLAIMS THEY DID NOT FALL. THE REVISION WAS PERFORMED TO RE-INSTRUMENT USING LARGER SCREWS OF A DIFFERENT PRODUCT. THIS IS REPORT ELEVEN OF TWELVE FOR THIS EVENT.
Patient problems: Failure of Implant
MAUDE report 20472155 ↗MalfunctionOct 15, 2024Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT A DISTRIBUTOR DISCOVERED A VITAL MIS DRIVER WITH A TWISTED TIP DURING A ROUTINE INSPECTION. THERE WAS NO REPORTED PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20453295 ↗InjuryAug 7, 2024Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT A T10-PELVIS REVISION SURGERY WAS CONDUCTED TO CORRECT SIX VITALITY SCREWS THAT WERE FOUND TO HAVE FRACTURED OR BENT POST-OPERATIVELY. NO FURTHER INFORMATION REGARDING PATIENT IMPACT OR REVISION TYPE IS AVAILABLE AT THIS TIME. THIS IS REPORT SIX OF SIX FOR THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 19933897 ↗InjuryAug 7, 2024Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT A T10-PELVIS REVISION SURGERY WAS CONDUCTED TO CORRECT SIX VITALITY SCREWS THAT WERE FOUND TO HAVE FRACTURED OR BENT POST-OPERATIVELY. NO FURTHER INFORMATION REGARDING PATIENT IMPACT OR REVISION TYPE IS AVAILABLE AT THIS TIME.THIS IS REPORT FIVE OF SIX FOR THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 19933894 ↗InjuryAug 7, 2024Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT A T10-PELVIS REVISION SURGERY WAS CONDUCTED TO CORRECT SIX VITALITY SCREWS THAT WERE FOUND TO HAVE FRACTURED OR BENT POST-OPERATIVELY. NO FURTHER INFORMATION REGARDING PATIENT IMPACT OR REVISION TYPE IS AVAILABLE AT THIS TIME. THIS IS REPORT FOUR OF SIX FOR THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 19933891 ↗InjuryAug 7, 2024Fracture; Fracture
IT WAS REPORTED THAT A T10-PELVIS REVISION SURGERY WAS CONDUCTED TO CORRECT SIX VITALITY SCREWS THAT WERE FOUND TO HAVE FRACTURED OR BENT POST-OPERATIVELY. NO FURTHER INFORMATION REGARDING PATIENT IMPACT OR REVISION TYPE IS AVAILABLE AT THIS TIME. THIS IS REPORT THREE OF SIX FOR THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 19933876 ↗InjuryAug 7, 2024Fracture; Fracture
IT WAS REPORTED THAT A T10-PELVIS REVISION SURGERY WAS CONDUCTED TO CORRECT SIX VITALITY SCREWS THAT WERE FOUND TO HAVE FRACTURED OR BENT POST-OPERATIVELY. NO FURTHER INFORMATION REGARDING PATIENT IMPACT OR REVISION TYPE IS AVAILABLE AT THIS TIME. THIS IS REPORT TWO OF SIX FOR THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 19933869 ↗InjuryAug 7, 2024Fracture; Fracture
IT WAS REPORTED THAT A T10-PELVIS REVISION SURGERY WAS CONDUCTED TO CORRECT SIX VITALITY SCREWS THAT WERE FOUND TO HAVE FRACTURED OR BENT POST-OPERATIVELY. NO FURTHER INFORMATION REGARDING PATIENT IMPACT OR REVISION TYPE IS AVAILABLE AT THIS TIME. THIS IS REPORT ONE OF SIX FOR THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 19933864 ↗MalfunctionMay 24, 2023Material Deformation; Material Deformation
IT WAS REPORTED THAT A VITAL MIS DRIVER STRIPPED INTRA-OPERATIVELY. THE SURGERY WAS COMPLETED WITH ANOTHER DRIVER. THERE ARE NO ADVERSE EVENTS OR PATIENT IMPACTS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16994408 ↗InjurySep 14, 2021Fracture; Fracture
IT WAS REPORTED A REVISION SURGERY WAS PERFORMED TO ADDRESS POST-OP SCREW BREAKAGE AND MALUNION. PRIOR TO THE REVISION, THE SURGEON THOUGHT ONE SCREW WAS BROKEN, BUT THREE SCREWS WERE FOUND TO BE BROKEN DURING THE REVISION. THE SHAFTS OF THE THREE SCREWS WERE UNABLE TO BE REMOVED AND REMAIN IMPLANTED WITHIN THE PATIENT. NO NEW HARDWARE WAS ADDED DURING THE REVISION. THIS IS REPORT THREE OF THREE FOR THIS EVENT.
Patient problems: Foreign Body In Patient; Malunion of Bone
MAUDE report 12470947 ↗InjurySep 14, 2021Fracture; Fracture
IT WAS REPORTED A REVISION SURGERY WAS PERFORMED TO ADDRESS POST-OP SCREW BREAKAGE AND MALUNION. PRIOR TO THE REVISION, THE SURGEON THOUGHT ONE SCREW WAS BROKEN, BUT THREE SCREWS WERE FOUND TO BE BROKEN DURING THE REVISION. THE SHAFTS OF THE THREE SCREWS WERE UNABLE TO BE REMOVED AND REMAIN IMPLANTED WITHIN THE PATIENT. NO NEW HARDWARE WAS ADDED DURING THE REVISION. THIS IS REPORT ONE OF THREE FOR THIS EVENT.
Patient problems: Foreign Body In Patient; Malunion of Bone
MAUDE report 12470943 ↗InjurySep 14, 2021Fracture; Fracture
IT WAS REPORTED A REVISION SURGERY WAS PERFORMED TO ADDRESS POST-OP SCREW BREAKAGE AND MALUNION. PRIOR TO THE REVISION, THE SURGEON THOUGHT ONE SCREW WAS BROKEN, BUT THREE SCREWS WERE FOUND TO BE BROKEN DURING THE REVISION. THE SHAFTS OF THE THREE SCREWS WERE UNABLE TO BE REMOVED AND REMAIN IMPLANTED WITHIN THE PATIENT. NO NEW HARDWARE WAS ADDED DURING THE REVISION. THIS IS REPORT TWO OF THREE FOR THIS EVENT.
Patient problems: Foreign Body In Patient; Malunion of Bone
MAUDE report 12470909 ↗
Other Biomet Spine LLC products
All Biomet Spine LLC devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page