Synthes 5.0mm Variable Locking Screw recallZ-1125-2014 · Synthes, Inc. · initiated Feb 5, 2014
Class II Terminated All recalls posted in March 2014
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Synthes, Inc. or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Labeling correction: The package insert in one 5.0mm Variable Locking Screw package was a GP0006 (Anterior Cervical Vertebrae Plate System) insert, which should have been a GP2848 (4.5mm VA-LCP Curved Condylar Plate System insert).
FDA root cause category: Employee error
What the company is doing
Synthes sent an Urgent Field Safety Notification/Medical Device Labeling Correction letter to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to: Exchage the previously shipped package insert (GP0006) with the correct package insert (GP2848 provided with the notification). Review the package insert. Forward the Field Safety Notification to anyone in their facility that needs to be informed. If the package insert has been forwarded to another facility, contact that facility. Maintain awareness of this notice until all package inserts have been exchanged. Maintain a copy of the notice. Customers with questions were instructed to maintain a copy of the notice. For questions regarding this recall call 610-719-5000.
Recall details
- Recall number
- Z-1125-2014
- Recall class
- Class II
- Status
- Terminated
- Initiated by the company
- Feb 5, 2014
- Posted by the FDA
- Mar 4, 2014
- Recalling firm
- Synthes, Inc.
- Quantity
- 45
- Product code
- JDP
- FDA submissions
- K110354
- Distribution
- Nationwide Distribution including GA, CA, TX, MO, OH, PA, WA, AL, IN, AZ, MI, IA, TN, KY, NC, VA, NY, LA, IL, UT, and KS.
Product description
Synthes 5.0mm Variable Locking Screw This device is part of the Variable Angle Locking Compression Plate family and this technology included variable angle Combi holes in the plate shaft.The variable angle Combi hole provides the flexibility of axial compression and variable locking capacity throughout the length of the plate shaft.
Code information (models, lots, serial numbers)
part no. 02.231.240, lot no. 823111
Other devices under the same FDA submission
78 devices cleared under K110354 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.
- VA-LCP 03.231.007Synthes GmbH · condylar plate fixation Implant56 reports
- VA-LCP 03.231.005Synthes GmbH · condylar plate fixation Implant37 reports
- VA-LCP 02.124.416Synthes GmbH · condylar plate fixation Implant24 reports
- VA-LCP 02.124.412Synthes GmbH · Screw, fixation, bone21 reports
- VA-LCP 02.124.417Synthes GmbH · Screw, fixation, bone16 reports
- VA-LCP 02.124.413Synthes GmbH · condylar plate fixation Implant14 reports
- NA 02.231.280Synthes GmbH · PLATE, FIXATION, BONE13 reports
- VA-LCP 02.124.408Synthes GmbH · condylar plate fixation Implant12 reports
- VA-LCP 02.124.410Synthes GmbH · Screw, fixation, bone12 reports
- VA-LCP 02.124.418Synthes GmbH · PLATE, FIXATION, BONE12 reports
- VA-LCP 03.231.004Synthes GmbH · Screw, fixation, bone12 reports
- NA 02.231.675Synthes GmbH · condylar plate fixation Implant11 reports
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 18, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page