ENROUTE Transcarotid Stent recallZ-1146-2021 · Silk Road Medical Inc · initiated Jan 13, 2021
Terminated
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Silk Road Medical Inc or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Due to complaints received that the tip/nose cone may detach from the Transcarotid Stent System.
FDA root cause category: Under Investigation by firm
What the company is doing
On 01/13/2021, the firm sent an "URGENT: MEDICAL DEVICE RECALL" Notification via email to customers informing them that product complaints have been received where the tip/nose cone detached from the stent delivery system during use and it is possible the resulting patient harm can range from minor intervention required to retrieve the detached tip/nose cone to embolization or stroke if the device failure goes undetected. Customers are instructed to: 1. Immediately removed the affected lots from hospital inventory and quarantine the products in a secure location until such time as the Recalling Firm can arrange for removal from their facility. The affected units will be permanently removed from commercial distribution. There is no need for action related to devices already used during a procedure. 2. Immediately upon receipt of the email notification, reply to the email to [email protected] and record the number of units for each affected lot 3. If not impacted products remain in their facility or a Recalling Firm's field representative has already removed the affected products, customer are to indicated this accordingly on the email reply. For any questions, contact the Recalling Firm at 855-410-8227 ext. 2110 Monday through Friday 8:00 a.m. to 5:00 p.m. Pacific Time or email [email protected]
Recall details
- Recall number
- Z-1146-2021
- Status
- Terminated
- Initiated by the company
- Jan 13, 2021
- Recalling firm
- Silk Road Medical Inc
- Quantity
- Total = 455 systems
- Product code
- NIM
- FDA submissions
- P140026
- Distribution
- U.S.: AZ, CA, CO, CT, DC, DE, FL, GA, HI, IL, IN, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, WA, WI, and WV. O.U.S.: None
Product description
ENROUTE Transcarotid Stent System REF SR-XXYY-CS
Code information (models, lots, serial numbers)
Catalog Number: SR0930CS UDI Code: (01)00811311020492(17)211130(10)17917092 Lot Number: 17917092 Catalog Number: SR0930CS UDI Code: (01)00811311020492(17)211231(10)17923717 Lot Number: 17923717 Catalog Number: SR1030CS UDI Code: (01)00811311020522(17)220131(10)17929776 Lot Number: 17929776 Catalog Number: SR1040CS UDI Code: (01)00811311020539(17)220131(10)17931107 Lot Number: 17931107 Catalog Number: SR0940CS UDI Code: (01)00811311020508(17)230131(10)301576 Lot Number: 301576
Devices named in this recall
4 devices in the FDA device registry whose identifier appears in the recall's code information.
- ENROUTE Transcarotid Stent SR-0940-CSSilk Road Medical, Inc. · Stent, Carotid1 recall5 deaths58 reports
- ENROUTE Transcarotid Stent SR-1040-CSSilk Road Medical, Inc. · Stent, Carotid1 recall3 deaths56 reports
- ENROUTE Transcarotid Stent SR-0930-CSSilk Road Medical, Inc. · Stent, Carotid1 recall1 death21 reports
- ENROUTE Transcarotid Stent SR-1030-CSSilk Road Medical, Inc. · Stent, Carotid1 recall2 deaths15 reports
Product lines
Other devices under the same FDA submission
10 devices cleared under P140026 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.
- ENROUTE Transcarotid Stent SR-0840-CSSilk Road Medical, Inc. · Stent, Carotid2 deaths60 reports
- ENROUTE Transcarotid Stent SR-0830-CSSilk Road Medical, Inc. · Stent, Carotid22 reports
- ENROUTE Transcarotid Stent FG11815Silk Road Medical, Inc. · Stent, Carotid2 deaths17 reports
- ENROUTE Transcarotid Stent SR-0740-CSSilk Road Medical, Inc. · Stent, Carotid13 reports
- ENROUTE Transcarotid Stent FG11815Silk Road Medical, Inc. · Stent, Carotid1 death13 reports
- ENROUTE Transcarotid Stent FG11815Silk Road Medical, Inc. · Stent, Carotid1 death10 reports
- ENROUTE Transcarotid Stent SR-0730-CSSilk Road Medical, Inc. · Stent, Carotid7 reports
- ENROUTE Transcarotid Stent FG11815Silk Road Medical, Inc. · Stent, Carotid1 death6 reports
- ENROUTE Transcarotid Stent FG11815Silk Road Medical, Inc. · Stent, Carotid1 death3 reports
- ENROUTE Transcarotid Stent SR-0640-CSSilk Road Medical, Inc. · Stent, Carotid2 reports
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page