RayStation (Radiation Treatment Planning System) recallZ-2138-2021 · Raysearch Laboratories AB · initiated Jun 8, 2021

Terminated

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from Raysearch Laboratories AB or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

Initial delivery positions will be set incorrectly when having setup beam(s) at the localization point.

FDA root cause category: Under Investigation by firm

What the company is doing

RaySearch issued Urgent Field Safety Notice, Medical Device Correction #80230 via email on 06/08/21. Letter states reason for recall, health risk and action to take: TO BE TAKEN BY THE USER " Do not create setup beams with the localization point as isocenter (option 2). " Always perform secondary verification of new treatment positions. RayTreat will notify the user when the treatment positions have been updated. " Always perform imaging before treating the patient. " Educate planning staff and all users about this workaround. " Inspect your product and identify all installed units with the above software version number(s). " Confirm you have read and understood this notice by replying to the notification email. SOLUTION This issue will be resolved in the next version of RayStation, scheduled for market release in June 2021 (subject to market clearance in some markets). If customers wish to continue using versions of RayStation affected by this notice, all users must maintain awareness of this notice. Alternatively, customers can choose to upgrade to the new version once it becomes available for clinical use. For regulatory information, please contact [email protected].

Recall details

Recall number
Z-2138-2021
Status
Terminated
Initiated by the company
Jun 8, 2021
Recalling firm
Raysearch Laboratories AB
Quantity
5 units
Product code
MUJ
FDA submissions
K200487, K200569
Distribution
US distribution to TN; and Belgium

Product description

RayStation (Radiation Treatment Planning System) : RayStation 9A, 9B, 9B SP1, 10A, 10A SP1, 10B and 11A, in combination with RayCare Model Numbers/ UDI: RayStation 9.0 (9.0.0.113) 07350002010174; RayStation 9.1 (9.1.0.933) 07350002010266; RayStation 9.1 Service Pack 1 (9.2.0.483) 07350002010297; RayStation 10.0 (10.0.0.1154) 07350002010303; RayStation 10.0 Service Pack 1 (10.0.1.52) 07350002010365; RayStation 10.1 (10.1.0.613) 07350002010310; RayStation 11.0 (11.0.0.951) 07350002010389;

Code information (models, lots, serial numbers)

Product name (build number) UDI-DI RayStation 9.0 (9.0.0.113) 07350002010174 RayStation 9.1 (9.1.0.933) 07350002010266 RayStation 9.1 Service Pack 1 (9.2.0.483) 07350002010297 RayStation 10.0 (10.0.0.1154) 07350002010303 RayStation 10.0 Service Pack 1 (10.0.1.52) 07350002010365 RayStation 10.1 (10.1.0.613) 07350002010310 RayStation 11.0 (11.0.0.951) 07350002010389

Devices named in this recall

6 devices in the FDA device registry whose identifier appears in the recall's code information.

Other devices under the same FDA submission

1 device cleared under K200487, K200569 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page