MAQUET CARDIOHELP recallZ-1053-2024 · Maquet Medical Systems USA · initiated Dec 28, 2023
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Maquet Medical Systems USA or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
The Bubble Sensor optional accessory to the CARDIOHELP-i extracorporeal life support system includes an incorrect UDI Device Identifier (DI) provided with the label attached to the device.
FDA root cause category: Labeling mix-ups
What the company is doing
An Urgent Medical Device Correction Letter was sent VIA Fed-Ex 2-day delivery with signature proof of delivery to all consignees with the following instructions: Actions to be taken by the Customer: - Please examine your inventory immediately to determine if you have any affected product in your inventory. - Whether or not your facility has affected product(s) listed in this notice, please complete and sign the attached MEDICAL DEVICE - CORRECTION RESPONSE FORM to acknowledge that you have received this notification. Return the completed form to Getinge by e-mailing a scanned copy to [email protected] or by faxing the form to 1-866-416-5299. - Affected Bubble Sensors do not need to be returned and can be used as-is. - Please forward this information to all current and potential Bubble Sensor users within your hospital / facility. - If you are a distributor who has shipped any affected products to customers, please forward this document to their attention for appropriate action. If you have any questions, please contact your Getinge representative or call Getinge Customer Support at (888) 943-8872 (press option 2), Monday through Friday, between the hours of 8:00 a.m. and 6:00 p.m. (Eastern Time Zone).
Recall details
- Recall number
- Z-1053-2024
- Status
- Open, Classified
- Initiated by the company
- Dec 28, 2023
- Posted by the FDA
- Feb 8, 2024
- Recalling firm
- Maquet Medical Systems USA
- Quantity
- 274 units (70 US, 204 OUS)
- Product code
- DTQ
- FDA submissions
- K133598
- Distribution
- AZ, CA, CO, FL, GA, IA, IL, MN, NE, PA, TX, WA and WI.
Product description
Bubble Sensor (REF: 70105.5720)
Code information (models, lots, serial numbers)
Show the full code information (1k characters)
Model: BS 3/8x3/32 L1.7; Correct UDI DI: 04037691816432; Incorrect UDI DI (as labeled): 04058863025148; SNs: 90041799 90041816 90041938 90042009 90042069 90041802 90041817 90041939 90042011 90042070 90041804 90041818 90041940 90042036 90042071 90041805 90041821 90041943 90042037 90042074 90041806 90041822 90041957 90042038 90042076 90041807 90041823 90041963 90042042 90042079 90041808 90041826 90041966 90042049 90042083 90041809 90041836 90041974 90042050 90042085 90041810 90041898 90041983 90042054 90042089 90041811 90041905 90041993 90042056 90042090 90041812 90041907 90041994 90042058 90042092 90041813 90041921 90041995 90042060 90042093 90041814 90041925 90041997 90042063 90042094 90041815 90041930 90042005 90042066 90042097;
Devices named in this recall
1 device in the FDA device registry whose identifier appears in the recall's code information.
- MAQUET CARDIOHELP BS 3/8x3/32 L1.7Maquet Cardiopulmonary AG · Console, Heart-Lung Machine, Cardiopulmonary Bypass2 recalls0 reports
Product lines
Other devices under the same FDA submission
4 devices cleared under K133598 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.
- MAQUET CARDIOHELP CARDIOHELP-iMaquet Cardiopulmonary AG · CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS5 recalls2 deaths64 reports
- MAQUET CARDIOHELP CARDIOHELP SystemMaquet Cardiopulmonary AG · CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS4 recalls18 deaths107 reports
- MAQUET CARDIOHELP CARDIOHELP Emergency Drive (w/o holder)Maquet Cardiopulmonary AG · CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS1 recall0 reports
- MAQUET CARDIOHELP CARDIOHELP Base UnitMaquet Cardiopulmonary AG · CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS2 reports
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page