EVIS EXERA II COLONOVIDEOSCOPE recallZ-1205-2024 · Olympus Corporation of the Americas · initiated Jan 11, 2024
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Olympus Corporation of the Americas or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Specific repaired colonovideoscopes were assembled without an adhesive which protects them from certain physical conditions such as high levels of vibration, fluctuation in temperature or severe shock loads.
FDA root cause category: Nonconforming Material/Component
What the company is doing
On January 11, 2024, the firm notified customers of the issue via URGENT MEDICAL DEVICE REMOVAL letters. Customers were instructed to inspect your inventory and identify any products of the model and lots subject to this action. Please check all areas of the hospital to determine if any of these devices remain in inventory. Quarantine and stop using the device. Customers were given detailed instructions on how to identify affected product. Our Olympus Customer Solutions team will contact you to arrange a no-charge return, and a loaner as necessary. Olympus will perform an inspection of your device, repair the variable stiffness mechanism if required, and return your device at no charge to you. Please acknowledge receipt of this matter through the recall portal at https://olympusamerica.com/recall, Enter the recall number "0437" and complete the form as instructed. Customers who have further distributed product should notify downstream accounts at once. Please report to Olympus any adverse events and/or irregularities with the use of the devices by contacting the Olympus Technical Assistance Center at 1- 800-848-9024, option 1. Adverse events experienced with the use of this product may also be reported to the FDA's MedWatch Adverse Event Reporting program either online, by regular mail, or by fax. If you have questions about this recall, please contact the recalling firm at (647) 999-3203 or by e-mail at [email protected].
Recall details
- Recall number
- Z-1205-2024
- Status
- Open, Classified
- Initiated by the company
- Jan 11, 2024
- Posted by the FDA
- Feb 29, 2024
- Recalling firm
- Olympus Corporation of the Americas
- Quantity
- 36
- Product code
- NWB
- FDA submissions
- K100584
- Distribution
- US Nationwide distribution.
Product description
Colonoscope, Model Number CF-H180AL.
Code information (models, lots, serial numbers)
Model Number: CF-H180AL; UDI DI: 4953170339608; Serial Number: 2001426, 2001524, 2001614, 2002139, 2002212, 2002285, 2103817, 2104137, 2104581, 2105255, 2105976, 2107112, 2207880, 2207929, 2207940, 2309317, 2601078, 2601096, 2601255, 2601368, 2601700, 2702380, 2702460, 2702478, 2702805, 2703697, 2704366, 2704490, 2806996, 2807975, 2900004, 2900185, 2900249, 2908770, 2909110, 2909884;
Devices named in this recall
1 device in the FDA device registry whose identifier appears in the recall's code information.
- EVIS EXERA II COLONOVIDEOSCOPE OLYMPUS CF TYPE H180ALOlympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid2 recalls72 reports
Product lines
Other products in the same recall event
The FDA groups related products into one recall event (event 93832).
- Z-1206-2024 · Open, ClassifiedColonoscope, Model Number CF-HQ190I.
- Z-1207-2024 · Open, ClassifiedColonoscope, Model Number CF-HQ190L.
- Z-1208-2024 · Open, ClassifiedColonoscope, Model Number CF-Q180AL.
- Z-1209-2024 · Open, ClassifiedColonoscope, Model Number PCF-H180AL.
- Z-1210-2024 · Open, ClassifiedColonoscope, Model Number PCF-H190DL.
- Z-1211-2024 · Open, ClassifiedColonoscope, Model Number PCF-H190L.
- Z-1212-2024 · Open, ClassifiedColonoscope, Model Number PCF-H190TL.
- Z-1213-2024 · Open, ClassifiedColonoscope, Model Number PCF-HQ190L.
- Z-1214-2024 · Open, ClassifiedColonoscope, Model Number PCF-Q180AL.
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page