Skip to content

Preat Nobel Active/Conical-compatible RP Titanium Blank… recallZ-1321-2024 · Preat Corp · initiated Feb 9, 2024

Open, Classified

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from Preat Corp or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

Due to a manufacturing issue, the screw seat location on the abutment product may be too high, causing mating screw to have a shorter engagement length into the associated implant.

FDA root cause category: Process change control

What the company is doing

On 02/09/2024, the firm sent an "URGENT: MEDICAL DEVICE RECALL" Letter via US certified mail to customers to inform them that the abutment was manufactured with a dimensional condition that may lead to reduced engagement between the prosthetic screw and the implant. Customer are instructed to inspect their inventory and discard or return the affected products to PREAT CORPORATION. For questions or further assistance contact the Quality Assurance Manager at 800-232-7732 or email at [email protected] On 2/16/2024, the firm sent via certified USPS mail an "URGENT: MEDICAL DEVICE RECALL UPDATE" which informs customer to notify all personnel within their company, and of their customers where the affected products may have been further distributed of the recall.

Recall details

Recall number
Z-1321-2024
Status
Open, Classified
Initiated by the company
Feb 9, 2024
Posted by the FDA
Mar 20, 2024
Recalling firm
Preat Corp
Quantity
561 units
Product code
NHA
FDA submissions
K183518
Distribution
U.S. Nationwide distribution in the states of AZ, OH and PA.

Product description

Preat Nobel Active/Conical-compatible RP Titanium Blank, REF 9000967

Code information (models, lots, serial numbers)

Model Number: 9000967 UDI-DI code: 00842092165867 Lot Numbers: 235650, 234294, 233667, 233885, 233439, and 231489

Devices named in this recall

1 device in the FDA device registry whose identifier appears in the recall's code information.

Other devices under the same FDA submission

4 devices cleared under K183518 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page