Nonsterile convenience kits recallZ-2229-2024 · MEDLINE INDUSTRIES, LP - Northfield · initiated Mar 14, 2024
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from MEDLINE INDUSTRIES, LP - Northfield or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Surgical convenience kits containing Pure Pouch component that has weak seals which may result in a breach in sterility of the contents if the seal fails.
FDA root cause category: Process control
What the company is doing
The recalling firm issued two different letters on and dated 3/14/2024 via first class mail and email. One of the letters was for the recall of the non-sterile kits and the other letter was flagged as a Safety Alert for the sterile kits. The recall letter for the non-sterile kits explained the issue of the Pure Pouches (which is the packaging for a sterile component) contained within the kits have been found to have weak seals which may not be detectable to the user. This would result in a breach of sterility of the component within the Pure Pouch. The hazard of the sterility breach was explained and required actions were listed which were: (1) Immediately check your stock for the affected item number and the affected lot numbers which can be located within the recall portal and quarantine all affected product immediately; (2) Use the login link and the information in the letter to complete the response form. List the quantity of affected product in inventory on the form, regardless of whether or not it is in inventory, and submit the form; (3) Upon receipt of the response form, the account will receive over-labels to place on affected inventory with instructions for the staff to remove the affected component prior to using the kit. The labels will be provided via FedEx overnight; and (4) If the account is a distributor or has resold or transferred this product to another company or individual, the account is to notify them of this recall communication. The letter regarding the sterile kits was flagged as a safety alert and explained the issue of the Pure Pouches contained within the kits have weak seals. The letter went onto say that despite the Pure Pouch having a weak seal, the kit lots were sterilized in a Medline-validated ethylene oxide (EO) process that renders the component(s) within the Pure Pouch sterile. Medline stated they are issuing this safety alert to reiterate that the kit is single-use only. In the event the affected components are not
Recall details
- Recall number
- Z-2229-2024
- Status
- Open, Classified
- Initiated by the company
- Mar 14, 2024
- Posted by the FDA
- Jun 28, 2024
- Recalling firm
- MEDLINE INDUSTRIES, LP - Northfield
- Quantity
- 7,673 total non-sterile kits
- Product code
- MLS
- Distribution
- US Nationwide distribution in the states of AL, CA, CO, CT, FL, IL, IN, MD, MN, MT, NC, NJ, NV, NY, OH, PA, SC, TN, TX, VA, WA, WI, and WY.
Product description
Nonsterile convenience kits: a. Medline Delivery, Pack #DYNJ901130I, containing a Pure Pouch with component Reorder #DYND04000, O.R. Scissors, S/B, 5.5 Sterile. b. Medline C-Section, Pack DYNJ902938J, containing a Pure Pouch with component Reorder #DYND04000, O.R. Scissors, S/B, 5.5 Sterile.
Code information (models, lots, serial numbers)
a. Pack #DYNJ901130I - Lot numbers 23GMH075, exp. 7/31/2024, and 23GMD605, exp. 7/31/2024, UDI-DI each-10193489946055 and UDI-DI case-40193489946056. b. Pack DYNJ902938J - Lot numbers 23LMD530, 23IMG375, 23HMB336, 23GMF342, 23EMJ935, and 23EMK254, all exp. date 8/31/2024, UDI-DI each-10193489946116, UDI-DI case 40193489946117.
Devices named in this recall
2 devices in the FDA device registry whose identifier appears in the recall's code information.
- Medline Industries, Inc. DYNJ902938JMedline Industries, Inc. · Cesarean section tray2 recalls0 reports
- Medline Industries, Inc. DYNJ901130IMedline Industries, Inc. · Labor and Delivery Kit1 recall0 reports
Other products in the same recall event
The FDA groups related products into one recall event (event 94239).
- Z-2224-2024 · Open, ClassifiedSterile surgical convenience kits: a. Medline Cath Lab Special Procedure, Pack #00-RDF0360, containing a Pure Pouch with component Medline Reorder #DYNJ04048, Kelly Forceps/STD …
- Z-2225-2024 · Open, ClassifiedSterile surgical convenience kit: Medline Retrograde PK-22025203-LF, Pack #DYNJ47873L, containing a Pure Pouch with component Sterile Curved Kelly Hemostat, Reorder #66175.
- Z-2226-2024 · Open, ClassifiedSterile surgical convenience kit: Medline Neuro IR Pack, Pack #DYNJ56073C, containing a Pure Pouch with component Medline Reorder #DYNJ04048, Kelly Forceps/STD STR Sterile.
- Z-2228-2024 · Open, ClassifiedSterile convenience kits: a. Medline Retrograde PK-22025203-LF, Pack #DYNJ47873K, containing a Pure Pouch containing component Sterile Curved Kelly Hemostat, Reorder #66175. b. …
- Z-2230-2024 · Open, ClassifiedNon-sterile convenience kits: a. Medline Difficult Airway Tray W/O Cook, Pack #ACC010578, containing a Pure Pouch with component Reorder #DYNJ040408, Kelly Forceps/STD STR Steril…
- Z-2231-2024 · Open, ClassifiedNon-sterile convenience kits: Medline Open Heart CDS, Pack #CDS981759C, containing a Pure Pouch with component Reorder #DYNJ04048, Kelly Forceps/STD STR Sterile.
- Z-2232-2024 · Open, ClassifiedNon-sterile convenience kits: a. Medline CC Drawer 4 IV Circulation, Pack #ACC010254B, containing a Pure Pouch component DYND04000, O.R. Scissors S/B, 5.5 Sterile. b. Medline Co…
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page