Skip to content

Non-sterile convenience kits recallZ-2231-2024 · MEDLINE INDUSTRIES, LP - Northfield · initiated Mar 14, 2024

Open, Classified

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from MEDLINE INDUSTRIES, LP - Northfield or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

Surgical convenience kits containing Pure Pouch component that has weak seals which may result in a breach in sterility of the contents if the seal fails.

FDA root cause category: Process control

What the company is doing

The recalling firm issued two different letters on and dated 3/14/2024 via first class mail and email. One of the letters was for the recall of the non-sterile kits and the other letter was flagged as a Safety Alert for the sterile kits. The recall letter for the non-sterile kits explained the issue of the Pure Pouches (which is the packaging for a sterile component) contained within the kits have been found to have weak seals which may not be detectable to the user. This would result in a breach of sterility of the component within the Pure Pouch. The hazard of the sterility breach was explained and required actions were listed which were: (1) Immediately check your stock for the affected item number and the affected lot numbers which can be located within the recall portal and quarantine all affected product immediately; (2) Use the login link and the information in the letter to complete the response form. List the quantity of affected product in inventory on the form, regardless of whether or not it is in inventory, and submit the form; (3) Upon receipt of the response form, the account will receive over-labels to place on affected inventory with instructions for the staff to remove the affected component prior to using the kit. The labels will be provided via FedEx overnight; and (4) If the account is a distributor or has resold or transferred this product to another company or individual, the account is to notify them of this recall communication. The letter regarding the sterile kits was flagged as a safety alert and explained the issue of the Pure Pouches contained within the kits have weak seals. The letter went onto say that despite the Pure Pouch having a weak seal, the kit lots were sterilized in a Medline-validated ethylene oxide (EO) process that renders the component(s) within the Pure Pouch sterile. Medline stated they are issuing this safety alert to reiterate that the kit is single-use only. In the event the affected components are not

Recall details

Recall number
Z-2231-2024
Status
Open, Classified
Initiated by the company
Mar 14, 2024
Posted by the FDA
Jun 28, 2024
Recalling firm
MEDLINE INDUSTRIES, LP - Northfield
Quantity
7,673 total non-sterile kits
Product code
OEZ
Distribution
US Nationwide distribution in the states of AL, CA, CO, CT, FL, IL, IN, MD, MN, MT, NC, NJ, NV, NY, OH, PA, SC, TN, TX, VA, WA, WI, and WY.

Product description

Non-sterile convenience kits: Medline Open Heart CDS, Pack #CDS981759C, containing a Pure Pouch with component Reorder #DYNJ04048, Kelly Forceps/STD STR Sterile.

Code information (models, lots, serial numbers)

Pack #CDS981759C - Lot numbers 24ADA460, exp. 7/31/2025; 23KDB724, exp. 7/31/2025; 23JDA205, exp. 10/31/2025; 23IDA683, exp. 11/30/2025; and 23EDA124, exp. 5/31/2025; UDI-DI each-10888277524002 and UDI-DI case-5/31/2025.

Devices named in this recall

1 device in the FDA device registry whose identifier appears in the recall's code information.

Other products in the same recall event

The FDA groups related products into one recall event (event 94239).

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page