Baxter Spectrum IQ Infusion System with Dose IQ Safety… recallZ-1254-2025 · Baxter Healthcare Corporation · initiated Feb 5, 2025
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from Baxter Healthcare Corporation or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
There is the potential for missing motor mounting screws, which may have occurred during the servicing process.
FDA root cause category: Under Investigation by firm
What the company is doing
Baxter issued an "URGENT MEDICAL DEVICE RECAL" notice to its consignees on 02/05/2025 via US Mail. The notice explained the issue, hazard involved, and requested the following actions be taken: "1. Immediately locate, isolate, and cease all use of Spectrum pumps with the affected serial numbers. The product code and serial number can be found on the bottom of the infusion pump. 2. Contact Baxter to arrange for the return of the affected pumps for inspection and reservicing as applicable. 3. If you received this communication directly from Baxter, acknowledge receipt on the enclosed reply form even if you have no remaining inventory. If you do not complete the acknowledgement, you will receive a phone call from OnProcess Technology on behalf of Baxter to confirm your receipt of this notification. 4. If you purchased this product from a distributor or wholesaler, please note that responding on the Baxter customer portal is not applicable. If a response is requested by your distributor or wholesaler, please respond to them according to their instructions. 5. Please forward a copy of this communication to all departments within your institution who use the affected product. 6. If you are a dealer, wholesaler, distributor/reseller, or original equipment manufacturer (OEM) that distributed any affected product to other facilities, please conduct a user-level recall of the affected product that you distributed to customers and check the associated box on the customer portal. For general questions regarding this communication, or quality problems, please contact your Baxter sales representative, or Baxter Global Technical Services at 800-843-7867 Monday through Friday, between 7:00 am and 7:00 pm Eastern Time."
Recall details
- Recall number
- Z-1254-2025
- Status
- Open, Classified
- Initiated by the company
- Feb 5, 2025
- Posted by the FDA
- Mar 6, 2025
- Recalling firm
- Baxter Healthcare Corporation
- Quantity
- 323 units
- Product code
- FRN
- FDA submissions
- K230041
- Distribution
- US: Nationwide
Product description
Baxter Spectrum IQ Infusion System with Dose IQ Safety Software, Product Code 3570009
Code information (models, lots, serial numbers)
Show the full code information (3k characters)
UDI/DI 00085412610900, Serial Numbers: 3020290, 3020992, 3020996, 3021929, 3023080, 3023183, 3023537, 3023758, 3500529, 3502799, 3502864, 3510806, 3511639, 3512647, 3514801, 3516888, 3517399, 3517517, 3518558, 3519053, 3564064, 3564818, 3565462, 3565620, 3566022, 3566254, 3567145, 3567218, 3567998, 3568527, 3568922, 3570910, 3571100, 3571598, 3571972, 3573147, 3573504, 3574293, 3575033, 3575107, 3576026, 3576443, 3656732, 3657316, 3657541, 3657814, 3657821, 3657995, 3659259, 3660176, 3660244, 3662986, 3664495, 3665624, 3721608, 3721910, 3721946, 3722620, 3723725, 3724211, 3730270, 3730408, 3732309, 3732476, 3734858, 3735010, 3735261, 3735734, 3738122, 3744219, 3744455, 3746159, 3746749, 3749111, 3749929, 3764591, 3767418, 3519969, 3520138, 3520706, 3520746, 3520829, 3521120, 3521338, 3606099, 3607097, 3607681, 3608730, 3609223, 3610668, 3610820, 3611120, 3611140, 3611650, 3612298, 3612886, 3613052, 3614035, 3615599, 3615816, 3616449, 3666443, 3666451, 3667116, 3668076, 3668654, 3668851, 3669058, 3669126, 3669307, 3670942, 3671444, 3672061, 3672846, 3676099, 3677241, 3679511, 3680542, 3681596, 3681981, 3686743, 3689421, 3691453, 3691496, 3693341, 3696268, 3618354, 3619039, 3619876, 3620296, 3620427, 3620631, 3620643, 3620757, 3621068, 3621252, 3621777, 3623915, 3623963, 3624131, 3624546, 3627519, 3628177, 3630964, 3632085, 3632710, 3632830, 3633267, 3634729, 3634792, 3699321, 3699388, 3699822, 3699917, 3700350, 3700551, 3701785, 3703127, 3703425, 3703513, 3703840, 3704056, 3704228, 3705346, 3706311, 3706762, 3706856, 3707896, 3002100, 3003072, 3004069, 3006254, 3006831, 3009116, 3009918, 3011726, 3012929, 3013032, 3013567, 3014990, 3015179, 3015242, 3016501, 3018280, 3018908, 3020206, 3576448, 3576730, 3576867, 3577158, 3578268, 3578536, 3578772, 3578906, 3584933, 3587077, 3588099, 3590690, 3591061, 3591360, 3591997, 3593297, 3634941, 3635142, 3637457, 3638689, 3640189, 3642200, 3642537, 3642720, 3645079, 3645908, 3646680, 3647126, 3647441, 3647540, 3647866, 3648851, 3648878, 3650355, 3650984, 3651372, 3654108, 3655491, 3655618, 3655785, 3655938, 3656531, 3521873, 3521999, 3522038, 3522253, 3522529, 3523783, 3523984, 3524348, 3524522, 3528869, 3528966, 3529402, 3529628, 3529632, 3529636, 3529928, 3529935, 3530350, 3530787, 3531077, 3531419, 3534705, 3539485, 3539740, 3540240, 3540832, 3595222, 3598809, 3599437, 3601012, 3601382, 3602225, 3603240, 3603637, 3603686, 3603842, 3603852, 3603947, 3604716, 3605640, 3605644, 3605994, 3697496, 3697667, 3697864, 3698034, 3698139, 3698336, 3699050, 3699248, 3541085, 3542213, 3542383, 3542809, 3542839, 3543062, 3543083, 3543172, 3544259, 3546132, 3548337, 3548404, 3549047, 3552392, 3554222, 3554971, 3555901, 3555949, 3556168, 3556278, 3556819, 3556876, 3557131, 3557902, 3560245, 3562324, 3562649, 3562705, 3562975, 3616568, 3616648, 3617327, 3617431, 3617744, 3708183, 3708637, 3708695, 3709027, 3709669, 3710188, 3711475, 3714210, 3715824, 3717594, 3718985.
Devices named in this recall
1 device in the FDA device registry whose identifier appears in the recall's code information.
- Spectrum IQ 3570009Baxter Healthcare Corporation · Infusion safety management software11 recalls10 deaths9,086 reports
Other products in the same recall event
The FDA groups related products into one recall event (event 96289).
- Z-1253-2025 · Open, ClassifiedBaxter Sigma Spectrum Infusion System (V6 Platform), Product Code 35700BAX
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page