Skip to content

Covidien Signia" Small Diameter Curved Tip Intelligent… recallZ-0486-2026 · Covidien, LP · initiated Sep 25, 2025

Open, Classified

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from Covidien, LP or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

A manufacturing issue could lead to a malformed cover tube press which can lead to internal components' movement during firing - leading to the potential for uncontrolled motion.

FDA root cause category: Process control

What the company is doing

On September 25, 2025 URGENT: MEDICAL DEVICE RECALL letters were sent to customers. Customer actions: Identify and quarantine all unused impacted product listed. Return all quarantined devices to Medtronic. If purchased from a distributor, contact your distributor directly to arrange for the return of the devices back to your distributor. Please complete and return the enclosed Customer Confirmation Form. Pass on this notice to all those who need to be aware within your organization or to any organization where the listed affected lots may have been transferred or distributed.

Recall details

Recall number
Z-0486-2026
Status
Open, Classified
Initiated by the company
Sep 25, 2025
Posted by the FDA
Nov 7, 2025
Recalling firm
Covidien, LP
Quantity
2 units (OUS only)
Product code
GDW
FDA submissions
K191070
Distribution
Worldwide distribution - US Nationwide and the countries of Austria, Belgium, Chile, Estonia, Finland, France, Germany, Greece, Hungary, Israel, Italy, Japan, Kuwait, Malaysia, Netherlands, Poland, Portugal, Romania, Saudi Arabia, Slovakia, Spain, United Kingdom.

Product description

Covidien Signia" Small Diameter Curved Tip Intelligent Reload (45mm Vascular/Thin); BOX LOBECTOMIA VATS 3D; CFN: BOX06170V4;

Code information (models, lots, serial numbers)

CFN: BOX06170V4; UDI-DI: 00763000988975; Lot numbers: 0231961695;

Other devices under the same FDA submission

3 devices cleared under K191070 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.

Other products in the same recall event

The FDA groups related products into one recall event (event 97792).

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page