Oncology sets with drip chambers recallZ-3158-2026 · ICU Medical, Inc. · initiated May 12, 2026
Open, Classified
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from ICU Medical, Inc. or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
Intravascular administration tubing set drip chambers may have black specks potentially due to the plastic molding process leaving discolored polyvinyl chloride (PVC) material within the drip chamber wall that does not enter the fluid path, which if seen by a healthcare provider may lead to replacement of product before use, which could result in a delay in therapy.
FDA root cause category: Process control
What the company is doing
On 5/12/2026, the firm posted a Information Regarding Reported Black Specks in Certain IV Tubing Set Drip Chambers from ICU Medical document on their website. On 5/18/2026, updated the notices were sent. On 7/28/2026, correction notices were sent to customers asking them to do the following: 1) Share this notification with all potential users of the device to ensure they are aware of this notification. If the devices are used or further distributed to another location, please ensure that this communication is delivered there. 2) Complete and return the attached Customer Response Form to [email protected] 3) Continue using products as intended and per facility protocol. 4) Report any product quality concerns to ICU Medical Complaint Management. Firm contacts: [email protected] 1-866-261-8806. [email protected] 1-800-258-5361
Recall details
- Recall number
- Z-3158-2026
- Status
- Open, Classified
- Initiated by the company
- May 12, 2026
- Posted by the FDA
- Sep 11, 2026
- Recalling firm
- ICU Medical, Inc.
- Quantity
- 107,800
- Product code
- FPA
- FDA submissions
- K081361
- Distribution
- Worldwide - US Nationwide distribution including in the states and territories of ND, TX, CT, KY, CO, AR, NC, NJ, VA, MD, OK, AK, IA, IN, KS, OR, CA, OH, WA, GA, AL, SC, MA, HI, FL, NH, NE, MN, MS, SD, MT, NY, DC, ID, WI, PA, AZ, MO, NV, TN, NM, WV, WY, IL, UT, MI, RI, VT, LA, DE, ME, VI, GU, PR and the countries of PK, PH, MY, HK, IN, DE, CR.
Product description
Oncology sets with drip chambers
Code information (models, lots, serial numbers)
All products manufactured on or before 7/4/2026. UDI-DI: 10840619054486, 10887709091914
Devices named in this recall
2 devices in the FDA device registry whose identifier appears in the recall's code information.
- ICU Medical CH3322Icu Medical, Inc. · Set, administration, intravascular1 recall0 reports
- ICU Medical CH3731Icu Medical, Inc. · Set, administration, intravascular1 recall0 reports
Other devices under the same FDA submission
18 devices cleared under K081361 are not named by identifier in this recall. One submission often covers many models, so they may or may not be affected.
- ICU Medical CH3025Icu Medical, Inc. · Set, administration, intravascular1 recall0 reports
- ICU Medical CH3035Icu Medical, Inc. · Set, administration, intravascular1 recall0 reports
- ICU Medical Z7107Icu Medical, Inc. · Set, administration, intravascular1 recall0 reports
- ICU Medical CL4001Icu Medical, Inc. · Set, administration, intravascular1 recall0 reports
- ICU Medical CH3639Icu Medical, Inc. · Set, administration, intravascular1 recall0 reports
- ICU Medical CH3581Icu Medical, Inc. · Set, administration, intravascular16 reports
- ICU Medical CH4000Icu Medical, Inc. · Set, administration, intravascular11 reports
- ICU Medical CH3943Icu Medical, Inc. · Set, administration, intravascular6 reports
- ICU Medical CH-72Icu Medical, Inc. · Set, administration, intravascular5 reports
- ICU Medical CV-100Icu Medical, Inc. · Set, administration, intravascular2 reports
- ICU Medical CH3554Icu Medical, Inc. · Set, administration, intravascular2 reports
- ICU Medical 20116-01Icu Medical, Inc. · Set, administration, intravascular1 report
Other products in the same recall event
The FDA groups related products into one recall event (event 99058).
- Z-3156-2026 · Open, ClassifiedPlum administration sets
- Z-3157-2026 · Open, ClassifiedIV Non-Dedicated Gravity Administration Sets with drip chambers
- Z-3159-2026 · Open, ClassifiedOncology sets with drip chambers
- Z-3160-2026 · Open, ClassifiedIV Sets with drip chambers
- Z-3161-2026 · Open, ClassifiedIV Sets with drip chambers
- Z-3162-2026 · Open, ClassifiedIV Sets with drip chambers
- Z-3163-2026 · Open, ClassifiedIV Sets with drip chambers
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 16, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page