Skip to content

Ingenia recallZ-3318-2026 · Philips North America · initiated Aug 28, 2026

Open, Classified

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from Philips North America or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

When exporting diffusion tensor imaging (DTI) scans from a MR system using the Enhanced MR DICOM format, the exports contain incorrect data (diffusion directions). If the Enhanced MR DICOM export is used in conjunction with third-party software for tractography (e.g. for mapping nerve fiber pathways in the brain), the software will not be able to correctly process the DTI data for reconstruction.

FDA root cause category: Software design

What the company is doing

On August 28, 2026, URGENT Medical Device Correction letters were sent to customers. Actions to be taken: 1. To prevent the issue from occurring while Philips is developing the software solution, use the Classic DICOM transfer option for exporting DTI scans. 2. You may continue to use your system(s) in accordance with the intended use. 3. Circulate this notice to all users of this device so that they are aware of the issue and associated hazard/harm. 4. Please retain this Urgent Medical Device Correction letter with your system(s) until the software upgrade is installed; ensure the notice is in a place likely to be seen/viewed.

Recall details

Recall number
Z-3318-2026
Status
Open, Classified
Initiated by the company
Aug 28, 2026
Posted by the FDA
Sep 25, 2026
Recalling firm
Philips North America
Quantity
91
Product code
LNH
FDA submissions
K213583, K223458, K251397, K251808
Distribution
Worldwide distribution - Nationwide and the countries of Algeria, Argentina, Australia, Austria, Bangladesh, Belgium, Brazil, Canada, Chile, China, Colombia, Cyprus, Czech Republic, Denmark, Dominican Rep, Ecuador, Egypt, Equator. Guinea, Finland, France, French Guiana, Georgia, Germany, Ghana, Greece, Honduras, Hong Kong, Hungary, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Kenya, Kyrgyzstan, Latvia, Lebanon, Luxembourg, Malaysia, Malta, Martinique, Mauritius, Mexico, Moldova, Monaco, Morocco, Myanmar, Namibia, Nepal, Netherlands, New Zealand, Nicaragua, Norway, Pakistan, Palestine, Peru, Philippines, Poland, Portugal, Qatar, Romania, Russian Fed., Saudi Arabia, Serbia, Singapore, Slovakia, South Africa, South Korea, Spain, Sweden, Switzerland, Syria, Taiwan, Thailand, Tunisia, T¿rkiye, United Kingdom, Uruguay, Utd.Arab.Emir., Uzbekistan, Vietnam.

Product description

Evolution upgrade 1.5T amd Evolution upgrade 3.0T; Model number (REF): 1. 782116 (1.5T), 2. 782148 (1.5T), 3. 782166 (1.5T), 4. 782201(1.5T), 5. 782117 (3.0T), 6. 782143 (3.0T), 7. 782162 (3.0T); Software Versions: R11, R12 and R13;

Code information (models, lots, serial numbers)

Show the full code information (1k characters)

1. Model number (REF): 782116 (1.5T); UDI-DI: 00884838099722; Serial Numbers: 41042, 41235, 41287, 41295, 41367, 41505, 41568, 70068, 70093, 70995, 70996, 84370; 2. Model number (REF): 782148 (1.5T); UDI-DI: 00884838108714; Serial Numbers: 41011, 41031, 41110, 41244, 41277, 41334, 41427, 41446, 41464, 41523, 41534, 70425, 70454, 70473, 70622, 70630, 70644, 70769, 70803, 70966, 70983, 84102, 84409, 84560, 84569, 84630, 84825; 3. Model number (REF): 782166 (1.5T); UDI-DI: 00884838115774; Serial Numbers: 41005, 41161, 41485, 41499, 41572, 70155, 70206, 70826, 84048, 84270, 84541; 4. Model number (REF): 782201 (1.5T); UDI-DI: 00884838128552; Serial Numbers: 84018, 84648; 5. Model number (REF): 782117 (3.0T); UDI-DI: 00884838099739; Serial Numbers: 42023, 42024, 42078, 42375, 71348, 85681, 85705; 6. Model number (REF): 782143 (3.0T); UDI-DI: 00884838108660; Serial Numbers: 42069, 42225, 42254, 42318, 42366, 42415, 42440, 71389, 71460, 71595, 71815, 71836, 85649, 85651, 85654, 85682, 85683, 85688, 85690, 85695, 85697, 85699, 85701, 85714; 7. Model number (REF): 782162 (3.0T); UDI-DI: 00884838115736; Serial Numbers: 42184, 42369, 71074, 71403, 71433, 71574, 71740, 85145;

Devices named in this recall

7 devices in the FDA device registry whose identifier appears in the recall's code information.

Product lines

Other products in the same recall event

The FDA groups related products into one recall event (event 99834).

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page