TRUEbalance TRUEbalance 10 Blood Glucose Test StripsRecalls & reported problems

Trividia Health, Inc. · TRUEbalance 10 Blood Glucose Test Strips · Class 2

All models of TRUEbalance (3)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00021292007942), received between Feb 22, 2017 and Feb 22, 2017 — classified as 1 malfunction.

The most frequently reported specific device problem is “Low Test Results” (1 report).

2 other recalls cover devices cleared under the same FDA submission (K090495); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Low Test Results1

Patient problems

  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 22, 2017Low Test Results; Low Test Results

    CONSUMER REPORTED COMPLAINT FOR LOW BLOOD GLUCOSE TEST RESULTS. THE CUSTOMER IS CONCERNED WITH TESTS RESULTS FROM RESULTS OBTAINED OF 48 MG/DL. THE CUSTOMER'S EXPECTED FASTING BLOOD GLUCOSE TEST RESULT RANGE IS 85 - 92 MG/DL. AT THE TIME OF CALL ON (B)(6) 2017 , THE CUSTOMER FELT WELL AND DID NOT REPORT ANY SYMPTOMS. THE CUSTOMER STATED SHE DID NOT FEEL ANY HYPOGLYCEMIC SYMPTOMS AT THE TIME OF RECEIVING LOW RESULT OF 48 MG/DL (FASTING) ON (B)(6) 2017. MEDICAL ATTENTION IS NOT REPORTED AS A RESULT OF THE ACTUAL BLOOD GLUCOSE RESULTS. DURING THE CALL ON (B)(6) 2017, A BACK TO BACK BLOOD TEST WAS NOT PERFORMED BY THE CUSTOMER. THE PRODUCT IS NOT STORED ACCORDING TO SPECIFICATION AND IS STORED IN THE KITCHEN. THE TEST STRIP LOT MANUFACTURER'S EXPIRATION DATE IS 09/30/2018 AND OPEN VIAL DATE AT TIME OF CALL IS THREE WEEKS. CUSTOMER STATED SHE HAS NOT HAD ANY RECENT CHANGES IN DIET, EXERCISE, OR MEDICATIONS. CUSTOMER STATED SHE TAKES GLIPIZIDE AND ACTOS FOR DIABETES MANAGEMENT. THE METER MEMORY WAS REVIEWED FOR PREVIOUS TEST RESULT HISTORY (DATE/TIME NOT SET): 87MG/DL (B)(6) 2017 10:39 PM FASTING:YES; 85MG/DL (B)(6) 2017 07:07 AM FASTING:YES; 70MG/DL (B)(6) 2017 07:57 AM FASTING:YES; 72M

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6349274 ↗

FDA clearance and classification

Cleared through Special 510(k) K090495 on Mar 27, 2009 (decision: Substantially Equivalent). Submitted by Home Diagnostics, Inc. as “Truebalance Blood Glucose System”. The FDA review took 30 days. FDA record ↗

The FDA regulates product code CGA (glucose oxidase, glucose) under 21 CFR 862.1345 as a Class II device. 21 CFR 862.1345 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K090495. One submission often covers many models, so check the product and lot details in each record.

  • Z-2883-2016 · Jun 28, 2016 · Open, Classified
    TRUEread Blood Glucose Test Strips (Glucose Oxidase) are used with TRUEresult and TRUE2go meters. TRUEread Blood Glucose Test Strips are available in vials with 10 ct., 25 ct., 50
  • Z-0909-2014 · Oct 2, 2013 · Terminated
    MooreMedical Supporting Health & Care...MooreBrand Blood Glucose Monitor for Self-Testing & Multi-Patient Use TRUEbalance. Manufactured by: NIPRO DIAGNOSTICS, Fort Lauderdale, FL 3

Common questions about the TRUEbalance TRUEbalance 10 Blood Glucose Test Strips

Has the TRUEbalance TRUEbalance 10 Blood Glucose Test Strips been recalled?

No FDA recall record in our data names this exact device identifier (DI 00021292007942), based on the FDA recall file dated Nov 27, 2026. However, 2 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the TRUEbalance TRUEbalance 10 Blood Glucose Test Strips?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Feb 22, 2017. That report lists device problem “Low Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the TRUEbalance TRUEbalance 10 Blood Glucose Test Strips?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the TRUEbalance TRUEbalance 10 Blood Glucose Test Strips FDA approved?

It was cleared through Special 510(k) K090495 on Mar 27, 2009. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the TRUEbalance TRUEbalance 10 Blood Glucose Test Strips, and is it still sold?

The FDA's device database lists Trividia Health, Inc. as the company responsible for it (brand TRUEbalance, model TRUEbalance 10 Blood Glucose Test Strips). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Glucose Oxidase, Glucose devices

All Glucose Oxidase, Glucose devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page