Flo-Thru Intraluminal Shunt® FT-12250Recalls & reported problems
Synovis Life Technologies, Inc. · The sterile, single use Flo-Thru Intraluminal Shunt is a one-piece radiopaque silicone tube with atraumatic bulbs shaped at each end. Openings at the ends of the bulbs allow blood to flow through the shunt and distal to the anastomosis. · Class 2
All models of Flo-Thru Intraluminal Shunt (9)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
1 FDA recall record name this device's identifier, 1 still open.
3 other recalls cover devices cleared under the same FDA submission (K981624); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Recalls naming this device
- Feb 22, 2024Class IIOpen, Classified
The Surgical Tools and Cardiovascular Specialty marketing brochures distributed for Flo-Rester Disposable Internal Vessel Occluder, Flo-Thru Intraluminal Shunt, and Vascular Probe Intravascular Probe contain inaccurate content that does not align with the products Instructions for Use (IFU).
Z-1522-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
FDA clearance and classification
Cleared through 510(k) K981624 on Aug 4, 1998 (decision: Substantially Equivalent). Submitted by Bio-Vascular, Inc. as “Flo-Thru”. The FDA review took 89 days. FDA record ↗
The FDA regulates product code DXC (clamp, vascular) under 21 CFR 870.4450 as a Class II device. 21 CFR 870.4450 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K981624. One submission often covers many models, so check the product and lot details in each record.
- Z-1523-2024 · Feb 22, 2024 · Open, ClassifiedSurgical Tools and Cardiovascular Specialty marketing brochures, Reference numbers: US-AS18-210002 Surgical Tools Brochure 2021, US-AS18-210004 Surgical Tools Website v1, and US-A
- Z-0663-2024 · Dec 6, 2023 · Open, ClassifiedBaxter Flo-Thru Intraluminal Shunt, Product Codes: a) Product Code FT12100, 1.00 GLOBAL; b) Product Code FT12125, 1.25 GLOBAL; c) Product Code FT12150, 1.50 GLOBAL; d) Product
- Z-1019-2022 · Apr 1, 2022 · TerminatedFlo-Thru Intraluminal Shunt. Used in coronary artery or peripheral vascular procedures. Used to shunt blood at the anastomosis to provide a temporary blood-free operative field for
Common questions about the Flo-Thru Intraluminal Shunt® FT-12250
Has the Flo-Thru Intraluminal Shunt® FT-12250 been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1522-2024 (Class II), began on Feb 22, 2024: The Surgical Tools and Cardiovascular Specialty marketing brochures distributed for Flo-Rester Disposable Internal Vessel Occluder, Flo-Thru Intraluminal Shunt, and Vascular Probe Intravascular Probe contain… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
Is the Flo-Thru Intraluminal Shunt® FT-12250 FDA approved?
It was cleared through 510(k) K981624 on Aug 4, 1998. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the Flo-Thru Intraluminal Shunt® FT-12250, and is it still sold?
The FDA's device database lists Synovis Life Technologies, Inc. as the company responsible for it (brand Flo-Thru Intraluminal Shunt®, model FT-12250). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CLAMP, VASCULAR devices
- Heartstring III System 3.8MM HSK-3038Maquet Cardiovascular LLC · Clamp, Vascular1 recall4 deaths814 reports
- Heartstring III System 4.3MM HSK-3043Maquet Cardiovascular LLC · Clamp, Vascular1 recall265 reports
- TR BAND TRB24-REGTerumo Medical Corporation · CLAMP, VASCULAR284 reports
- TR BAND TRB24-REGTerumo Medical Corporation · CLAMP, VASCULAR255 reports
- HeartString III Proximal Seal HS-3045Maquet Cardiovascular LLC · Clamp, Vascular1 recall187 reports
- TR BAND TRB29-LRGTerumo Medical Corporation · CLAMP, VASCULAR67 reports
- TR BAND TRB29-LRGTerumo Medical Corporation · CLAMP, VASCULAR63 reports
- Flo-Thru Intraluminal Shunt® FT-12125Synovis Life Technologies, Inc. · CLAMP, VASCULAR1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page