Skip to content

IceSeed H7493967433170Recalls & reported problems

Boston Scientific Corporation · Cryoablation Needle · Class 2

All models of IceSeed (2)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00191506032692), received between Sep 25, 2025 and Sep 25, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Thermal Decomposition of Device” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Mar 24, 2025Class IIOpen, Classified

    Boston Scientific has identified that IceSeedTM CX needles manufactured between April 2024 and February 2025 have been programmed with DEMO settings instead of Commercial settings (see Affected Product Listing). Upon initial connection of an IceSeed CX needle to the Cryoablation System, the user will be prompted to perform the Needle Integrity and Functionality Test (NIT) per standard protocols. The affected needles perform as intended unless they are disconnected and reconnected to any channel after testing. In this case, the Cryoablation System will prompt re-execution of the NIT.

    Z-1688-2025 · Root cause: Process control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Thermal Decomposition of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 25, 2025Thermal Decomposition of Device; Thermal Decomposition of Device

    IT WAS REPORTED THE FROST OCCURRED ON THE SHAFT OF THE NEEDLE. AN ICESEED 1.5 CX 90 DEGREES CRYOABLATION NEEDLE WAS CHOSEN FOR A CRYOABLATION PROCEDURE TO TREAT A NERVE FOR PAIN MANAGEMENT. DURING THE FIRST FREEZING CYCLE, FROST WAS OBSERVED ON THE ICESEED 1.5 CX 90 DEGREES CRYOABLATION NEEDLE AND THE FROST WAS TOUCHING THE PATIENT'S SKIN. THE PHYSICIAN APPLIED SALINE TO THE AREA TO DISSOLVE THE ICE, AND THE PATIENT'S SKIN DID NOT APPEAR TO BE AFFECTED BY THE EVENT. THE PROCEDURE WAS COMPLETED WITH THE ORIGINAL DEVICE AND FROST WAS NOT OBSERVED AGAIN ON THE SHAFT OF THE NEEDLE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23148522 ↗

Other UNIT, CRYOSURGICAL, ACCESSORIES devices

All UNIT, CRYOSURGICAL, ACCESSORIES devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page