Skip to content

A.L.P.S. mvX™ 770714102Recalls & reported problems

Tyber Medical, LLC · ANTLATERAL TIB PLT 10H RT WIDE · Class 2 · Implant

All models of A.L.P.S. mvX (25)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00196449015900), received between Dec 31, 2024 and Dec 31, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Difficult or Delayed Positioning” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult or Delayed Positioning1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 31, 2024Difficult or Delayed Positioning; Difficult or Delayed Positioning

    SURGEON TRIED PUTTING IN SCREW INTO OBLONG HOLE TOWARDS TOP OF THE ANTEROLATERAL DISTAL TIBIA PLATE AND SCREW HEAD BROKE OFF FAIRLY EASILY. HE THEN PUT A SCREW IN JUST PROXIMAL TO THE FIRST AND SCREW HEAD PASSED THROUGH THE PLATE AND WAS STUCK UNDER PLATE. 2-HOUR SURGICAL DELAY NOTED AFTER SURGEON TRIED TO REMOVE BROKEN SCREW AND THE SCREW UNDER THE PLATE. SCREW WAS DISCARDED AND PLATE WAS RETAINED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21049118 ↗

Other Plate, fixation, bone devices

All Plate, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page