CoaguChek XS Plus Professional Care Kit 5021537001Recalls & reported problems
Roche Diagnostics GmbH · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00365702164109), received between Aug 1, 2018 and Feb 9, 2023 — classified as 10 malfunctions.
The most frequently reported specific device problem is “Image Display Error/Artifact” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Image Display Error/Artifact6
- No Device Output2
- Audible Prompt/Feedback Problem1
- Display Difficult to Read1
- Display or Visual Feedback Problem1
- Unauthorized Access to Computer System1
Patient problems
- No Clinical Signs, Symptoms or Conditions9
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 9, 2023No Device Output; No Device Output
WE RECEIVED AN ALLEGATION OF AN INTERMITTENT DISPLAY ISSUE ON A COAGUCHEK XS PLUS METER. THE CUSTOMER ALLEGES THAT THE METER WILL DISPLAY AN INR RESULT FOR A FEW SECONDS AFTER RUNNING A TEST AND THEN THE RESULT WILL DISAPPEAR AND THE METER RETURNS TO THE MAIN MENU. THE HOURGLASS WILL THEN REAPPEAR ON THE DISPLAY SCREEN. NONE OF THE RESULTS FROM THIS ISSUE WERE LOCATED IN THE METER MEMORY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16333160 ↗MalfunctionOct 25, 2022Display or Visual Feedback Problem; No Device Output; Display or Visual Feedback Problem; No Device Output
THE INITIAL REPORTER STATED THERE WAS AN ISSUE WITH THE COAGUCHEK XS PLUS USER INTERFACE. THE SPECIFIC DATE OF THE EVENT IS NOT KNOWN AND STARTED OCCURRING APPROXIMATELY ON (B)(6) 2022. THE REPORTER STATED THE METER NO LONGER ASKS FOR THE OPERATOR ID. ADDITIONALLY, WHEN A PATIENT ID IS ENTERED, THE METER WILL START TYPING LETTERS ON ITS OWN, EVEN WHEN THE OPERATOR IS NOT PRESSING ANYTHING ON THE SCREEN. NO DISCREPANCIES WERE OBSERVED UPON METER POWER UP AND THE DISPLAY IS COMPLETE. THE REPORTER TRIED ACCESSING THE METER SET UP TO VERIFY WHETHER THE OPERATOR ID IS DISABLED. THE METER POPULATED AN ADMINISTRATOR BOX AND REQUESTED A PASSWORD. THE REPORTER WAS PROVIDED THE PASSWORD OF THE DAY, BUT THE METER REJECTED THE PASSWORD. FURTHER ATTEMPTS TO ENTER A PASSWORD WERE NOT SUCCESSFUL. THE REPORTER WAS INSTRUCTED TO ACCESS THE MAIN MENU AND ACCESS "PATIENT TEST". THE REPORTER WAS ABLE TO ENTER VARIOUS LETTERS AND ALL LETTERS SELECTED BY THE REPORTER WERE ENTERED. THE TYPING ISSUE COULD NOT BE RECREATED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15670669 ↗MalfunctionOct 14, 2022Image Display Error/Artifact; Audible Prompt/Feedback Problem; Image Display Error/Artifact; Audible Prompt/Feedback Problem
WE RECEIVED AN ALLEGATION ABOUT A DARK SCREEN ON A COAGUCHEK XS PLUS METER. IT WAS REPORTED THAT THE METER SCREEN IS TOO DARK TO CLEARLY READ OR INTERPRET THE RESULTS. THE SCREEN CONTRAST WAS INCREASED FROM 8 TO 10 BUT IS STILL TOO DARK TO READ. WHEN THE METER IS PLACED INTO THE BASE UNIT, THE RESULTS ARE STILL UPLOADED TO THE DMS SYSTEM. NO RESULTS HAVE BEEN MISINTERPRETED DUE TO THE DARK SCREEN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15609070 ↗MalfunctionSep 9, 2022Image Display Error/Artifact; Image Display Error/Artifact
WE RECEIVED AN ALLEGATION OF A DISPLAY ISSUE WITH 3 COAGUCHEK XS METERS. THIS MDR IS FOR METER #3. THE METER HAS BLACK LINES ON THE SCREEN. THE REPORTER DESCRIBED THE SCREEN AS "SIMILAR TO AN OLD TV". IT WAS VERIFIED THAT THE LINES WOULD INTERFERE WITH THE INTERPRETATION OF RESULTS. NO MISINTERPRETATION OF RESULTS WAS REPORTED. REFER TO MDR WITH PATIENT IDENTIFIER (B)(6) FOR THE INVESTIGATION OF METER #1 AND MDR WITH PATIENT IDENTIFIER (B)(6) FOR THE INVESTIGATION OF METER #2.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15394428 ↗MalfunctionSep 9, 2022Image Display Error/Artifact; Image Display Error/Artifact
WE RECEIVED AN ALLEGATION OF A DISPLAY ISSUE WITH 3 COAGUCHEK XS METERS. THIS MDR IS FOR METER #1. THE METER WOULD POWER ON, BRIEFLY FLASH A WHITE SCREEN, AND THEN A BLACK SCREEN. NO MISINTERPRETATION OF RESULTS WAS REPORTED. REFER TO MDR WITH - PATIENT IDENTIFIER (B)(6) FOR THE INVESTIGATION OF METER #2 AND MDR - PATIENT IDENTIFIER (B)(6) FOR THE INVESTIGATION OF METER #3.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15394402 ↗MalfunctionSep 9, 2022Image Display Error/Artifact; Image Display Error/Artifact
WE RECEIVED AN ALLEGATION OF A DISPLAY ISSUE WITH 3 COAGUCHEK XS METERS. THIS MDR IS FOR METER #2. THE METER HAS BLACK LINES ON THE SCREEN. THE REPORTER DESCRIBED THE SCREEN AS "SIMILAR TO AN OLD TV". IT WAS VERIFIED THAT THE LINES WOULD INTERFERE WITH THE INTERPRETATION OF RESULTS. NO MISINTERPRETATION OF RESULTS WAS REPORTED. REFER TO MDR WITH PATIENT IDENTIFIER (B)(6) FOR THE INVESTIGATION OF METER #1 AND MDR WITH PATIENT IDENTIFIER (B)(6) FOR THE INVESTIGATION OF METER #3.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15394352 ↗MalfunctionAug 25, 2022Image Display Error/Artifact; Image Display Error/Artifact
THE INITIAL REPORTER STATED THEY HAD A DISPLAY ISSUE WITH A COAGUCHEK XS PLUS METER SERIAL NUMBER (B)(4). THE METER DISPLAY HAS FADED SEGEMENTS. METER DISPLAYS THE ROCHE LOGO WHEN POWERED ON BUT THE REST OF THE DISPLAY HAS BLACK AND WHITE SQUIGGLES ON IT. NO MISINTERPRETATION OF RESULTS WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15294568 ↗MalfunctionJun 28, 2022Image Display Error/Artifact; Image Display Error/Artifact
THE INITIAL REPORTER STATED THERE WAS AN ISSUE WITH THE DISPLAY OF COAGUCHEK XS PLUS METER SERIAL NUMBER (B)(4). THE METER HAD SEGMENTS THAT WERE MISSING FROM THE RESULTS FIELD OF THE DISPLAY. THE ISSUE IMPEDED THE CUSTOMER'S ABILITY TO READ THE RESULTS FIELD OF THE DISPLAY. IT WAS NOTED THERE WERE LINES ON THE DISPLAY AND RAINBOW LIKE COLORS ALSO APPEARED ON THE DISPLAY. THE FACILITY HAS NOT MIS-REPORTED RESULTS DUE TO THE ISSUE. THE METER HAS NOT BEEN USED SINCE THE ISSUE WAS NOTICED. THE BATTERY COMPARTMENT OF THE METER WAS NOT SOILED AND THE CUSTOMER HAS NOTED THERE WAS NO MISUSE OF THE METER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14840183 ↗MalfunctionSep 21, 2021Display Difficult to Read; Display Difficult to Read
THE INITIAL REPORTER COMPLAINED OF A DISPLAY ISSUE WITH COAGUCHEK XS METER SERIAL NUMBER (B)(4). CUSTOMER STATED THE METER DISPLAY IS BLACK WITH A BIT OF BLUE AT THE BOTTOM OF THE SCREEN. CUSTOMER STATED THE ISSUE COULD IMPEDE THE ABILITY TO READ THE RESULTS. THERE WAS NO ALLEGATION THAT ANY TEST RESULTS HAD BEEN MISINTERPRETED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12507757 ↗MalfunctionAug 1, 2018Unauthorized Access to Computer System; Unauthorized Access to Computer System
AN INTERNAL INVESTIGATION HAS DETERMINED THAT COAGUCHEK XS PLUS METERS ARE VULNERABLE TO A CYBERSECURITY OR DATA BREACH. THIS WAS DISCOVERED DURING ROCHE INTERNAL INVESTIGATIONS IN CONJUNCTION WITH A CYBERSECURITY CONSULTANT. THE INTERNAL INVESTIGATION DETERMINED THAT SIGNIFICANT PRODUCT AND CYBERSECURITY KNOWLEDGE IS NEEDED TO EXPLOIT THESE VULNERABILITIES. THE CONSULTANT WAS ABLE TO REVERSE ENGINEER THE SERVICE PASSWORD GENERATOR. THE CONSULTANT WAS ALSO ABLE TO EXECUTE CODE THROUGH A HIDDEN COMMAND. THE INVESTIGATION DETERMINED THE FOLLOWING: DELETION OF PROTECTED HEALTH INFORMATION MAY BE POSSIBLE. MODIFICATION OF PROTECTED HEALTH INFORMATION MAY BE POSSIBLE. CHANGING THE UNITS OF MEASURE MAY BE POSSIBLE. THE VULNERABILITIES CAN BE EXPLOITED INDEPENDENTLY OR IN COMBINATION. IN THE WORST CASE SCENARIO, THE MEDICAL RISK IS HIGH. THE PROBABILITY OF THIS TYPE OF EVENT OCCURRING IS LOW (CRIMINAL INTENT, THEFT OF THE DEVICE, ENTERING THE FIREWALL, ETC.). THE LIKELIHOOD OF OCCURRENCE OF A SUCCESSFUL ATTACK IS DEEMED LOW TO THEORETICAL WITH INSTALLATIONS SECURED IN ACCORDANCE WITH ROCHE CYBER SECURITY RECOMMENDATIONS. THERE HAVE BEEN NO REPORTS OF ACTUAL OCCURRENCE IN THE FIELD.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7740425 ↗
FDA clearance and classification
The FDA regulates product code GJS (test, time, prothrombin) under 21 CFR 864.7750 as a Class II device. 21 CFR 864.7750 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the CoaguChek XS Plus Professional Care Kit 5021537001
Has the CoaguChek XS Plus Professional Care Kit 5021537001 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00365702164109), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CoaguChek XS Plus Professional Care Kit 5021537001?
The FDA's MAUDE database lists 10 adverse event reports for this device, received between Aug 1, 2018 and Feb 9, 2023. In those reports, the most common specific device problems are “Image Display Error/Artifact” (6), “No Device Output” (2) and “Audible Prompt/Feedback Problem” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CoaguChek XS Plus Professional Care Kit 5021537001?
None of the reports are classified as deaths, 0 as injuries and 10 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the CoaguChek XS Plus Professional Care Kit 5021537001, and is it still sold?
The FDA's device database lists Roche Diagnostics GmbH as the company responsible for it (brand CoaguChek XS Plus Professional Care Kit, model 5021537001). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other TEST, TIME, PROTHROMBIN devices
- COAGUCHEK XS PT TEST 6 STRIP 4625374160Roche Diagnostics GmbH · TEST, TIME, PROTHROMBIN3 deaths1,682 reports
- CoaguChek XS PT strips 4625315160Roche Diagnostics GmbH · TEST, TIME, PROTHROMBIN604 reports
- CoaguChek XS Patient Self Testing Care Kit 03666794001Roche Diagnostics GmbH · Test, Time, Prothrombin212 reports
- CoaguChek XS Patient Self Testing Care Kit 4837738001Roche Diagnostics GmbH · TEST, TIME, PROTHROMBIN137 reports
- i-STAT 03P89-24Abbott Point Of Care Inc. · TEST, TIME, PROTHROMBIN127 reports
- HemosIL ReadiPlasTin (20 mL) 00020301400Instrumentation Laboratory Company · TEST, TIME, PROTHROMBIN2 recalls2 reports
- Coag-sense 100218Coagusense Inc. · Test, Time, Prothrombin1 recall0 reports
- Coag-Sense Test Strip Kit, 50 ct. 100218Coagusense Inc. · Test, Time, Prothrombin1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page