The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00380657517008), received between Aug 17, 2018 and Sep 5, 2024 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Failure to Cut” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Failure to Cut1
- Self-Activation or Keying1
Patient problems
- Intraocular Pressure Decreased1
- Intraocular Pressure Increased1
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
- Vitreous Hemorrhage1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 5, 2024Failure to Cut; Failure to Cut
A NURSE REPORTED THAT THE PROBE COULD NOT CUT DURING VITRECTOMY SURGERY. THE SURGERY WAS COMPLETED AFTER REPLACING THE PROBE WITH ANOTHER ONE. THERE WAS NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20143091 ↗InjuryAug 3, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IN LITERATURE STUDY ARTICLE, A NON-HEALTH PROFESSIONAL REPORTED THAT TO COMPARE THE EFFECTIVENESS AND SAFETY OF A 27-GAUGE (27G) BEVELED-TIP VITRECTOMY PROBE IN MICROINCISION VITRECTOMY SURGERY (MIVS) WITH A CONVENTIONAL 25-GAUGE (25G) VITRECTOMY PROBE FOR THE TREATMENT OF SERIOUS PROLIFERATIVE DIABETIC RETINOPATHY (PDR). FIFTY-TWO PATIENTS WHO WERE DEFINITIVELY DIAGNOSED WITH PDR AND REQUIRED VITRECTOMY TO REMOVE THE PROLIFERATIVE MEMBRANE. THE PRIMARY OUTCOME MEASURE WAS THE PRODUCTIVITY OF CUTTING THE MEMBRANE THROUGHOUT THE OPERATION. THE IMPORTANT SECONDARY OUTCOME MEASURES WERE THE NUMBER OF VITRECTOMY PROBES (VPS) SWITCHED TO MICRO FORCEPS, INTRAOPERATIVE AND POSTOPERATIVE COMPLICATIONS, POSTOPERATIVE BEST-CORRECTED VISUAL ACUITY (BCVA) AND PREOPERATIVE INTRAOCULAR PRESSURE (IOP) OF PATIENTS DURING THE 6-MONTH FOLLOW-UP PERIOD. COMPARED WITH THE 25G FLAT-TIP VITRECTOMY PROBE, THE 27G BEVELED-TIP VITRECTOMY PROBE CONTRIBUTES TO REMOVING THE PROLIFERATIVE MEMBRANE MORE EFFICIENTLY AND EASILY. IT ALSO REDUCED THE OCCURRENCE OF INTRAOPERATIVE HEMORRHAGES AND THUS AVOIDED EXCESSIVE ELECTROCOAGULATION. IN TERMS OF TREATMENT OUTCOME, THE ADVANCED BEVEL-TIP VITRECTOMY PROBE IS AS EF
Patient problems: Intraocular Pressure Decreased; Intraocular Pressure Increased; Vitreous Hemorrhage
MAUDE report 17450547 ↗MalfunctionAug 17, 2018Self-Activation or Keying
STAFF REPORTED THAT A CONSTELLATION 27+ ULTRAVIT HANDPIECE WAS NOT WORKING PROPERLY. THE SURGEON NOTED THAT THE HANDPIECE WAS SUCTIONING WITHOUT THE FOOTPEDAL BEING DEPRESSED. A NEW HANDPIECE WAS USED TO COMPLETE THE PROCEDURE AS PLANNED AND NO HARM CAME TO THE PATIENT. THE HANDPIECE WAS SAVED FOR CLINICAL ENGINEERING AND WILL BE RETURNED TO THE MANUFACTURER FOR FAILURE ANALYSIS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7792625 ↗
Other Instrument, vitreous aspiration and cutting, ac-powered devices
- CONSTELLATION 8065751150Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered1 recall1,246 reports
- CONSTELLATION 8065753041Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered503 reports
- Centurion, OZil 8065751761Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered475 reports
- UNITY 00380650002969Alcon Laboratories, Inc. · Instrument, Vitreous Aspiration And Cutting, Ac-Powered271 reports
- Ozil 8065750469Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered261 reports
- Bausch + Lomb SE5523WVBausch & Lomb Incorporated · Instrument, Vitreous Aspiration And Cutting, Ac-Powered1 recall4 reports
- Infiniti 8065752160Alcon Laboratories, Inc. · Instrument, vitreous aspiration and cutting, ac-powered54 reports
- Bausch + Lomb SE5525WVBausch & Lomb Incorporated · Instrument, Vitreous Aspiration And Cutting, Ac-Powered1 recall2 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page