Constellation, ULTRAVIT, Engauge, 27+ 8065752417Recalls & reported problems

Alcon Laboratories, Inc. · 27+* ULTRAVIT* Vitrectomy Probe Beveled 27+* /10,000 CPM · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00380657524174), received between Nov 8, 2023 and Aug 13, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Failure to Cut” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Cut5
  • Complete Blockage1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 13, 2026Failure to Cut

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50236348 ↗
  • MalfunctionApr 22, 2026Failure to Cut

    A PHYSICIAN REPORTED THAT CUTS PER MINUTE (CPM) DID NOT INCREASE (CUTTING ISSUE) DURING CALIBRATION FOR SURGERY. NO ISSUE WITH ASPIRATION WAS REPORTED. THE PROCEDURE TYPE WAS UNKNOWN. THE PROCEDURE WAS COMPLETED ON SAME DAY, BUT IT WAS UNKNOWN HOW THE SURGERY WAS COMPLETED. THERE WAS NO PATIENT CONTACT WITH THE SUSPECT PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24951690 ↗
  • MalfunctionFeb 19, 2026Failure to Cut

    A PHYSICIAN REPORTED THAT PROBE WAS NOT ACTUATE BEFORE SURGERY. THE SURGERY WAS COMPLETED ON THE SAME DAY, BUT IT WAS UNKNOWN HOW THE SURGERY WAS COMPLETED. THE PROCEDURE TYPE WAS UNKNOWN. THERE WAS NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24385698 ↗
  • MalfunctionAug 6, 2025Failure to Cut; Failure to Cut

    A HEALTHCARE PROFESSIONAL REPORTED PROBE CUTTING WAS POOR DURING VITRECTOMY SURGERY. THE SURGERY WAS COMPLETED AFTER REPLACING THE PRODUCT WITH ANOTHER ONE. THERE WAS NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22727507 ↗
  • MalfunctionJul 18, 2025Complete Blockage; Complete Blockage

    A NURSE REPORTED THAT THE VITRECTOMY PROBE WAS BLOCKED WITH NO NEGATIVE PRESSURE BEFORE VITRECTOMY SURGERY. THE SURGERY WAS COMPLETED AFTER REPLACING THE PRODUCT WITH ANOTHER ONE. THERE WAS NO IMPACT TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22539946 ↗
  • MalfunctionNov 8, 2023Failure to Cut; Failure to Cut

    AN OTHER HEALTHCARE PROFESSIONAL REPORTED THAT PROBE COULD NOT CUT DURING THE VITRECTOMY SURGERY. THE SURGERY WAS COMPLETED AFTER REPLACING THE NEW PRODUCT. THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18097948 ↗

Other Unit, phacofragmentation devices

All Unit, phacofragmentation devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page