Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00380740161699), received between Apr 22, 2024 and Apr 22, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Low Test Results” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Low Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 22, 2024Low Test Results; Low Test Results
THE CUSTOMER OBSERVED FALSELY DEPRESSED CREATINE KINASE RESULTS FOR ONE PATIENT. THE FOLLOWING RESULTS FROM ONE PATIENT WERE PROVIDED: SID (B)(6). INITIAL RUN (ERROR CODE 1350 ¿UNABLE TO CALCULATE RESULT NO ABSORBANCE READS WITHIN ABSORBANCE RANGE¿). DILUTION: 1:2, NO RESULT EC1350. RESULTS WERE GENERATED WITH DILUTED SAMPLE (1:10): <70 U/L. REPEAT RUN ON SN (B)(6). (ERROR CODE 1350 ¿UNABLE TO CALCULATE RESULT NO ABSORBANCE READS WITHIN ABSORBANCE RANGE¿), DILUTION:1:2, NO RESULT, EC 1350. DILUTION:1:10, RESULT >42670 U/L. SID (B)(6). INITIAL RUN (ERROR CODE 1350 ¿UNABLE TO CALCULATE RESULT NO ABSORBANCE READS WITHIN ABSORBANCE RANGE¿) DILUTED SPECIMEN 1:2, NO RESULT EC 1350. DILUTED SPECIMEN 1:10; RESULT:<70 U/L. REPEAT RUN ON SN (B)(6). (ERROR CODE 1350 ¿UNABLE TO CALCULATE RESULT NO ABSORBANCE READS WITHIN ABSORBANCE RANGE¿), DILUTION:1:2, NO RESULT EC 1350, DILUTION:1:10, RESULT >42670. NO IMPACT TO PATIENT MANAGEMENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19156592 ↗
FDA clearance and classification
The FDA regulates product code CGS (nad reduction/nadh oxidation, cpk or isoenzymes) under 21 CFR 862.1215 as a Class II device. 21 CFR 862.1215 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the ARCHITECT 7D63-22
Has the ARCHITECT 7D63-22 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00380740161699), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the ARCHITECT 7D63-22?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 22, 2024. That report lists device problem “Low Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the ARCHITECT 7D63-22?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the ARCHITECT 7D63-22, and is it still sold?
The FDA's device database lists Abbott GmbH as the company responsible for it (brand ARCHITECT, model 7D63-22). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other NAD REDUCTION/NADH OXIDATION, CPK OR ISOENZYMES devices
- ARCHITECT 7D63-21Abbott Laboratories · NAD REDUCTION/NADH OXIDATION, CPK OR ISOENZYMES1 recall1,435 reports
- Alinity 08P4220Abbott GmbH · NAD REDUCTION/NADH OXIDATION, CPK OR ISOENZYMES2 reports
- Dimension Vista® Flex® reagent cartridge CKI 10464356Siemens Healthcare Diagnostics Inc. · NAD REDUCTION/NADH OXIDATION, CPK OR ISOENZYMES2 reports
- ADVIA Chemistry Creatine Kinase 10729780Siemens Healthcare Diagnostics Inc. · NAD REDUCTION/NADH OXIDATION, CPK OR ISOENZYMES1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.