FACS 335775Recalls & reported problems
Becton, Dickinson And Company · BD FACS 7-Color Setup Beads 25 Tests · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00382903357758), received between Jun 30, 2020 and May 8, 2025 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Device Markings/Labelling Problem” (3 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Recalls naming this device
- Jun 3, 2025Open, Classified
Due to customer complaints, errors in spectral overlap factors table for 7-color setup beads may affect accurate setup of the flow cytometry instrument prior to analyzing samples.
Z-2078-2025 · Root cause: Process control · FDA record ↗
Most reported problems
Device problems
- Device Markings/Labelling Problem3
- Calibration Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Patient Involvement1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 8, 2025Calibration Problem; Calibration Problem
IT WAS REPORTED THAT WHILE USING BD FACS¿ 7-COLOR SETUP BEADS 25 TESTS CONTAMINATION WAS OBSERVED. THERE WAS NO REPORT OF USER IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: "FAILING LOT". "1. WERE PATIENT SAMPLES CONTAMINATED OR WAS THERE CARRYOVER (CROSS-CONTAMINATION/MIXING) BETWEEN PATIENT SAMPLES? IF NO, NO FURTHER QUESTIONS REQUIRED. PATIENT SAMPLES CONTAMINATED, CARRYOVER BETWEEN PATIENT SAMPLES, UNKNOWN - GO TO QUESTION #2. YES. 2. PLEASE DESCRIBE ANY ADDITIONAL DETAILS: GO TO PATIENT SAMPLES CHECKLIST. PATIENT SAMPLES CHECKLIST: 1. DID THIS CAUSE ERRONEOUS RESULTS ON PATIENT SAMPLES FOR DIAGNOSTIC TESTING? IF YES, GO TO QUESTION #2. YES. IF NO, NO FURTHER QUESTIONS REQUIRED. 2. WAS AN ERRONEOUS LABORATORY RESULT FROM THE BDB PRODUCT REPORTED TO A CLINICIAN? IF YES, GO TO QUESTION #3. NO.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21988548 ↗MalfunctionNov 28, 2022Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT WHILE USING THE BD FACS¿ 7-COLOR SETUP BEADS 25 TESTS THAT THE LOT NUMBER ON TUBE DOES NOT MATCH VALUE PRINTED ON INDIVIDUAL TUBE WRAPPER THE TUBE IS SEALED IN. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: LOT NUMBER ON TUBE DOES NOT MATCH VALUE PRINTED ON INDIVIDUAL TUBE WRAPPER THE TUBE IS SEALED IN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15870415 ↗MalfunctionOct 4, 2022Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT WHILE USING BD FACS¿ 7-COLOR SETUP BEADS 25 TESTS BD 7 COLOR SETUP BEADS DON¿T HAVE A LINE ON THE LABEL. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER IT WAS REPORTED BY THE CUSTOMER THAT BD 7 COLOR SETUP BEADS DON¿T HAVE A LINE ON THE LABEL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15536667 ↗MalfunctionJun 30, 2020Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT THE SETUP TUBE WAS NOT LABELED DURING USE WITH A BD FACS¿ 7-COLOR SETUP BEADS 25 TESTS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: DISCOVERED A 7-COLOR SETUP TUBE WHICH WASN¿T LABELED. THE BEAD PELLET WAS THERE, BUT THERE WERE NO EVENTS SEEN DURING SETUP. HE TRIED ANOTHER TUBE AND THIS WAS OK. ADDITIONALLY, ON 2020-06-22 THE FSE PROVIDED THE FOLLOWING ADDITIONAL INFORMATION: THE CUSTOMER USED THE TUBE AFTER IT WAS EXPIRED, HE WAS AWARE OF THIS AND HE DIDN¿T CARE.
Patient problems: No Patient Involvement
MAUDE report 10213033 ↗
Other Counter, differential cell devices
- Cytomics FC500 UPS (CXP)Beckman Coulter, Inc. · Counter, Differential Cell1,196 reports
- CELL-DYN 08H67-01Abbott Laboratories · Counter, differential cell6 recalls269 reports
- Alinity 09P6801Abbott Laboratories · Counter, differential cell2 recalls96 reports
- FACSCanto 338960Becton, Dickinson And Company · Counter, differential cell1 recall117 reports
- Cytomics FC500 UPS (MPL)Beckman Coulter, Inc. · Counter, Differential Cell141 reports
- CELL-DYN 08H00-01Abbott Laboratories · Counter, differential cell1 recall90 reports
- CELL-DYN 09H39-01Abbott Laboratories · Counter, differential cell123 reports
- BD Multitest 662995Becton, Dickinson And Company · Counter, differential cell2 recalls1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page