Skip to content

Insyte Autoguard 382912Recalls & reported problems

Becton, Dickinson And Company · BD Insyte™ Autoguard™ BC Pro Winged Shielded IV Catheter Blood Control Technology 24 GA x 0.75 IN · Class 2

All models of Insyte Autoguard (20)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00382903829125), received between Jan 13, 2025 and Jan 13, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Device1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 13, 2025Defective Device; Defective Device

    IT WAS REPORTED THAT BD INSYTE AG BC GLOBAL WING CATHETER IS DEFECTIVE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, TRANSLATED FROM ITALIAN TO ENGLISH: INCIDENT DESCRIPTION: EMERGENCY SITUATION IN AN EMERGENCY ROOM: PAEDIATRIC PATIENT SEVERELY BURNT, SEVERAL ATTEMPTS AT VENOUS CANNULATION WITH THE DEVICE WERE PERFORMED BY EXPERIENCED HEALTH PERSONNEL (PAEDIATRICIAN, DOCTOR ANAESTHETIST, NEONATOLOGIST, PAEDIATRIC NURSE) WERE UNSUCCESSFUL. THE REASONS WERE: A. DIFFICULTIES IN THE SKIN TRANSITION. B. PLASTIC SHEATH OF THE NEEDLE PERMANENTLY IN THE VEIN CURLS OR HAS A BREAK IN CONTINUITY. C. THE END OPPOSITE THE NEEDLE, I.E. THE PIECE TO BE EXTRACTED IS TOO LONG AND TOO HEAVY, ALTERS THE BALANCE AND GRIP CHANNELLING, MAKING IT UNSUITABLE FOR THE ENDS HAND AND FOOT. D. HIGH RESISTANCE TO BLOOD FLOW WITHIN PLASTIC LUMEN PROBABLY DUE TO THE FACT THAT THE LUMEN IN TIP HAS A DIAMETER NI ARE: GREATER THAN THE LUMEN OF THE BASE. DEVICE AVAILABILITY: YES. PLACE AVAILABILITY: THE DEVICE IS NOT AVAILABLE. ARE AVAILABLE IN UO PS PIECES FROM THE SAME BATCH. ANY OTHER INFORMATION THE REPORTER WISHES TO PROVIDE TO THE MINISTRY OF HEALTH: HEALTH PERSONNEL HAVE COMPLAINED EXTENSIVE

    Patient problems: Insufficient Information

    MAUDE report 21137457 ↗

Other Introducer, catheter devices

All Introducer, catheter devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page