PINNACLE RSS602Recalls & reported problems

Terumo Medical Corporation · PINNACLE Introducer Sheath · Class 2

Quick summary

This Terumo Medical Pinnacle introducer sheath is a soft plastic sleeve placed over a needle to give doctors access to a blood vessel during heart catheterization and similar procedures. Most of the 34 reports describe leaking or blood spilling at the access site, and the sheath or catheter deforming, kinking, cracking or breaking off — sometimes leaving a fragment inside the patient that surgeons had to retrieve. There were 8 injuries and no deaths. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
33
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 33 adverse event reports that list this exact device (DI 00389701007472), received between May 19, 2016 and Feb 11, 2025 — classified as 7 injuries, 26 malfunctions.

The most frequently reported specific device problem is “Leak/Splash” (16 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Leak/Splash16
  • Material Deformation4
  • Break3
  • Fracture3
  • Detachment of Device or Device Component2
  • Bent1
  • Device Damaged Prior to Use1
  • Difficult to Advance1

Patient problems

  • No Consequences Or Impact To Patient17
  • Blood Loss6
  • No Clinical Signs, Symptoms or Conditions5
  • Foreign Body In Patient2
  • No Information2
  • No Patient Involvement2
  • Embolism/Embolus1
  • Hematoma1

Recent adverse event reports

The 25 most recent of 33 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 11, 2025Difficult to Remove; Difficult to Remove

    TERUMO MEDICAL RECEIVED MEDWATCH # (B)(4). THE EVENT DESCRIPTION STATES THAT: AN ELDERLY FEMALE WITH PERSISTENT ATRIAL FIBRILLATION WITH RAPID VENTRICULAR RESPONSE UNDERWENT AN ELECTROPHYSIOLOGY STUDY WITH DRUG STIMULATION AND ABLATION OF ATRIAL FIBRILLATION OF THE PULMONARY VEIN. UPON REMOVAL OF THE LEFT FEMORAL ARTERIAL SHEATH, THE DISTAL PORTION OF THE SHEATH WAS RETAINED AND COULD NOT BE ACCESSED PERCUTANEOUSLY. THE PROVIDER ELECTED TO LEAVE THE RETAINED PORTION IN PLACE. THERE WAS EVIDENCE OF GOOD HEMOSTASIS NOTED ON ULTRASOUND AS WELL AS FOLLOWING MANUAL COMPRESSION. THE SL2 SHEATH WAS REMOVED AND LEFT THE SHORT 8-FRENCH SHEATH IN PLACE ON THE RIGHT SIDE. ADDITIONALLY, WE PLACED A RIGHT FEMORAL ARTERIAL 5-FRENCH SHEATH FOR BLOOD PRESSURE MONITORING. AT THIS POINT, WE CONCLUDED THE PROCEDURE. THE PATIENT WAS EXTUBATED AND TRANSPORTED TO THE HOLDING AREA FOR FURTHER OBSERVATION AND BED REST. A SURGICAL CONSULTATION WAS OBTAINED, AND THE PATIENT WAS TAKEN TO THE OPERATING ROOM FOR EMERGENT EXPLORATION OF THE LEFT COMMON FEMORAL ARTERY AND THE LEFT COMMON FEMORAL VEIN, WITH REPAIR OF THE LEFT COMMON FEMORAL ARTERY IN TWO LOCATIONS ANTERIORLY AND POSTERIORLY, AND EXPLORATION OF TH

    Patient problems: Embolism/Embolus; Foreign Body In Patient

    MAUDE report 21360210 ↗
  • InjurySep 6, 2024Material Deformation; Material Deformation

    TERUMO MEDICAL OBTAINED AN FDA MEDWATCH REPORT # MW5157015. THE EVENT DESCRIPTION STATES THAT SHEATH & CATHETER BECAME KINKED DURING HEART CATHETERIZATION REQUIRING VASCULAR SURGEON INTERVENTION TO ELIMINATE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20155592 ↗
  • InjuryMay 10, 2024Material Separation; Material Separation

    THE USER FACILITY REPORTED THAT THE SHEATH BROKE INSIDE OF A PATIENT. IT WAS RETRIEVED AND SAVED. ADDITIONAL INFORMATION WAS RECEIVED ON 17APR2024: THE PROCEDURE BEING PERFORMED WAS A LEFT HEART DIAGNOSTIC ANGIO VIA RIGHT FEMORAL ACCESS. WHEN ATTEMPTING TO REMOVE THE SHEATH THEY PULLED UNTIL IT SEPARATED. ALL PIECES OF SHEATH WERE REMOVED IN THE CATH LAB. THE PATIENT WAS SENT TO SURGERY FOR ENDORACTOMY PATCH AND HEMATOMA EVACUATION. SIZE OF HEMATOMA WAS NOT RECEIVED. NO HISTORY OF FEMORAL CLOSURE AT THIS HOSPITAL. GROWING SHOT TAKEN, HOWEVER, NOT AVAILABLE AT THIS TIME. REPORTED BLOOD LOSS WAS LESS THAN 250ML. THE PATIENT WAS STABLE.

    Patient problems: Hematoma

    MAUDE report 19288710 ↗
  • InjuryAug 12, 2023Fracture; Fracture

    THE USER FACILITY REPORTED THAT THEY HAD A RIGHT GROIN ACCESS WITH 6 FR SHEATH (RSS602). ACCESS WAS OBTAINED WITHOUT DIFFICULTY, SINGLE STICK. PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) OF THE LEFT SUPERFICIAL FEMORAL ARTERY (SFA) PERFORMED AND TRANSFERRED TO RECOVERY. WHEN TIME FOR REMOVAL OF SHEATH POST PROCEDURE, THERE WERE UNABLE TO REMOVE SHEATH WITHOUT DILATOR FOR MANUAL PRESSURE. TRANSFERRED PATIENT TO PROCEDURE ROOM. MULTIPLE GROIN SHOTS PERFORMED NO ISSUES OR COMPLICATIONS NOTED. ADVANCED A DILATOR, SHEATH REMOVED WITH SOME RESISTANCE, MANUAL PRESSURE APPLIED, AND TEAR/NICK NOTED ON SHEATH. SURGEON CONSULTED FOR OPINION AND NO INTERVENTION WAS REQUIRED. THE VESSEL WAS CALCIFIED. GROIN SITE AND PATIENT BOTH STABLE. PATIENT WAS IN STABLE CONDITION. THE PROCEDURE OUTCOME WAS SUCCESSFUL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17537840 ↗
  • MalfunctionJun 10, 2023Leak/Splash; Leak/Splash

    ADDITIONAL INFORMATION WAS RECEIVED ON 19 MAY 2023: THE TYPE OF PROCEDURE PERFORMED WAS A LOWER LEG ANGIOGRAPHY. THE HUB WAS NOT DAMAGED. THE PROCEDURE WAS NOT COMPLETED, PROCEDURE CONCLUDED WHEN BLOOD WAS NOTICED AT FEMORAL ACCESS SITE. IK DEVICE WAS REMOVED, AND PROCEDURE CONCLUDED. ESTIMATED BLOOD LOSS WAS LESS 250 CCS. ADDITIONAL INFORMATION WAS RECEIVED ON 20 JUN 2023: ACCORDING TO THE PHYSICIAN THERE WAS NO SUTURE USED AND AND NO DIFFICULTY WITH INSERTING THE SHEATH.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 17102104 ↗
  • InjuryNov 26, 2022Break; Break

    A MAUDE DATABASE SEARCH CONDUCTED ON 30 OCT 2022 FOUND A MAUDE REPORT NUMBER 15484674. THE EVENT DESCRIPTION STATES: WHILE USING THE CATHETER IN CATH LAB, THE PATIENT MOVED SUDDENLY AND THE DISTAL 3/5 OF THE CATHETER SHEARED OFF AND LODGED IN THE PATIENT'S ILIAC ARTERY. THE INTERVENTIONALIST HAD GREAT DIFFICULTY RETRIEVING THE CATHETER PIECE AND THE PATIENT REACHED MAXIMUM OR NEAR MAXIMUM RADIATION EXPOSURE. THE PHYSICIAN FELT IT WAS SAFE TO LEAVE AND RETURN TO ATTEMPT RETRIEVAL ANOTHER DAY. THE RETRIEVAL WAS SUCCESSFUL. THE PATIENT CAME INTO THE HOSPITAL IN EXTREMIS, BUT THIS CATHETER EVENT DID NOT EXACERBATE HER CLINICAL CONDITION.

    Patient problems: Foreign Body In Patient

    MAUDE report 15867026 ↗
  • MalfunctionAug 16, 2021Difficult to Advance; Difficult to Advance

    THE USER FACILITY REPORTED THAT THE IK DEVICE CATHETER COULD NOT BE PASSED EASILY THROUGH THE SHEATH ONCE FEMORAL ACCESS WAS OBTAINED. A 6FR GUIDE WAS USED WITH THE IK DEVICE. THE SHEATH WAS REMOVED AND ANOTHER CORDIS 6FR SHEATH WAS USED. THE CASE WAS COMPLETED NORMALLY. THE PATIENT WAS IN STABLE CONDITION. THE PROCEDURE WAS COMPLETED NORMALLY. THERE WAS NO PATIENT INJURY, MEDICAL/SURGICAL INTERVENTION REQUIRED. ADDITIONAL INFORMATION WAS RECEIVED ON 27JULY2021: THE PROCEDURE WAS A PERCUTANEOUS CORONARY INTERVENTION (PCI).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12324999 ↗
  • MalfunctionFeb 16, 2021Detachment of Device or Device Component; Detachment of Device or Device Component

    THE USER FACILITY REPORTED THAT THE IK SHEATH WAS MISSING THE THREE WAY STOP COCK UPON OPENING THE SHEATH. THE CASE WAS A LEFT HEART CATHETERIZATION (LHC). THERE WAS NO PATIENT INJURY/MEDICAL OR SURGICAL INTERVENTION REQUIRED. THE PATIENT WAS KNOWN TO BE IN STABLE CONDITION. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH ANOTHER SHEATH. ADDITIONAL INFORMATION WAS RECEIVED ON 08DEC2020. THE SHEATH IS USUALLY FLUSHED WITH SALINE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11334201 ↗
  • MalfunctionOct 5, 2020Material Deformation; Material Deformation

    ADDITIONAL INFORMATION WAS RECEIVED ON 21OCTOBER2020: THE SIDE TUBE OR THE SHEATH WAS NOT EXPOSED TO ANY SOURCES OF HEAT AT ANY TIME DURING THE PROCEDURE. THE PINHOLE WAS NOT NOTED WHEN THE SHEATH WAS PREPPED. THE SHEATHS WERE STORED IN THE BOX THEY COME IN. THIS WAS THE ONLY SHEATH WHICH HAD THIS DAMAGE. ADDITIONAL INFORMATION WAS RECEIVED ON 10NOVEMBER2020: IT WAS REPORTED THAT THE DOCTOR USES A POWER INJECTOR 2/3RDS OF THE TIME DURING A PROCEDURE. THERE WAS A GOOD CHANCE IT WAS USED. THE DILATOR WAS NOT IN WHEN CONTRAST MEDIA WAS PUT IN. THERE WERE NO ISSUES NOTED ON THE SHEATH WHILE IT WAS FLUSHED. THE SHEATH WAS PLACED IN THE PATIENT. THE SIDE PORT DID BECOME KINKED PRIOR TO THE GROIN ANGIOGRAM. WHEN THE GROIN ANGIOGRAM WAS TAKEN, THE HOLE WAS NOTICED. NOT SURE HOW OR WHEN THE SIDE PORT BECAME KINKED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10627757 ↗
  • InjuryAug 25, 2020Break; Break

    THE USER FACILITY REPORTED THAT THE TIP OF THE SHEATH BROKE OFF WHEN REMOVING THE SHEATH AT THE END OF THE CASE. THE COMMON FEMORAL ARTERY WAS FAIRLY CALCIFIED. THE DOCTOR HAD TO SNARE THE BROKEN PIECE OUT AND EVERYTHING WAS OK. THE PATIENT WAS IN STABLE CONDITION. THE PROCEDURE OUTCOME WAS SUCCESSFUL. THE BLOOD LOSS WAS LESS THAN 250 CC'S. THERE WAS NO PATIENT INJURY, MEDICAL/SURGICAL INTERVENTION REQUIRED. ADDITIONAL INFORMATION WAS RECEIVED ON 19AUG2020: TERUMO MEDICAL RECEIVED AN FDA MEDWATCH REPORT # MW5095582. THE EVENT DESCRIPTION STATES: "DURING INTRA-OP ANGIOGRAM, INDUCER TIP CAME OFF WHEN SURGEON WAS PLACING THE GUIDEWIRE. SURGEON WAS ABLE TO RETRIEVE THE TIP FROM THE PATIENT."

    Patient problems: Blood Loss

    MAUDE report 10449228 ↗
  • MalfunctionJan 30, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK VALVE WAS TURNED OFF TO THE PATIENT, AND HAD BEEN FLUSHED, BLOOD WAS STILL GETTING INTO THE SHEATH. THE PHYSICIAN WAS CONCERNED THAT CLOTS BUILD UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING THE CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED ON 08JAN2020. THE CASE WAS REPORTED TO BE EITHER A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE CASE WAS SUCCESSFUL AND WAS COMPLETED WITH THE SAME SHEATH. THE EVENT DID NOT LEAD TO BLOOD LOSS, THE PATIENT WAS IN STABLE CONDITION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9649239 ↗
  • MalfunctionJan 30, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK VALVE WAS TURNED OFF TO THE PATIENT, AND HAD BEEN FLUSHED, BLOOD WAS STILL GETTING INTO THE SHEATH. THE PHYSICIAN WAS CONCERNED THAT CLOTS BUILD UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING THE CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED ON 08JAN2020. THE CASE WAS REPORTED TO BE EITHER A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE CASE WAS SUCCESSFUL AND WAS COMPLETED WITH THE SAME SHEATH. THE EVENT DID NOT LEAD TO BLOOD LOSS, THE PATIENT WAS IN STABLE CONDITION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9649238 ↗
  • MalfunctionJan 30, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK VALVE WAS TURNED OFF TO THE PATIENT, AND HAD BEEN FLUSHED, BLOOD WAS STILL GETTING INTO THE SHEATH. THE PHYSICIAN WAS CONCERNED THAT CLOTS BUILD UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING THE CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED ON 08JAN2020. THE CASE WAS REPORTED TO BE EITHER A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE CASE WAS SUCCESSFUL AND WAS COMPLETED WITH THE SAME SHEATH. THE EVENT DID NOT LEAD TO BLOOD LOSS, THE PATIENT WAS IN STABLE CONDITION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9649237 ↗
  • MalfunctionJan 29, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK VALVE WAS TURNED OFF TO THE PATIENT, AND HAD BEEN FLUSHED, BLOOD WAS STILL GETTING INTO THE SHEATH. THE PHYSICIAN WAS CONCERNED THAT CLOTS BUILD UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING THE CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED ON 08JAN2020. THE CASE WAS REPORTED TO BE EITHER A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE CASE WAS SUCCESSFUL AND WAS COMPLETED WITH THE SAME SHEATH. THE EVENT DID NOT LEAD TO BLOOD LOSS, THE PATIENT WAS IN STABLE CONDITION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9642623 ↗
  • MalfunctionJan 29, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK DEVICE VALVE IS TURNED OFF TO THE PATIENT AND IT HAS BEEN FLUSHED, BLOOD IS STILL GETTING INTO THE SHEATH. THE PHYSICIAN IS CONCERNED CLOT BUILDS UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED 08JANUARY2019: THE CASE PERFORMED WAS A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE PROCEDURE OUTCOME WAS SUCCESSFUL, THIS ISSUE DID NOT LEAD TO BLOOD LOSS. THE PATIENT WAS STABLE AND THE CASE WAS COMPLETED WITH THE SAME SHEATH.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9641619 ↗
  • MalfunctionJan 29, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK DEVICE VALVE IS TURNED OFF TO THE PATIENT AND IT HAS BEEN FLUSHED, BLOOD IS STILL GETTING INTO THE SHEATH. THE PHYSICIAN IS CONCERNED CLOT BUILDS UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED 08JANUARY2019: THE CASE PERFORMED WAS A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE PROCEDURE OUTCOME WAS SUCCESSFUL, THIS ISSUE DID NOT LEAD TO BLOOD LOSS. THE PATIENT WAS STABLE AND THE CASE WAS COMPLETED WITH THE SAME SHEATH.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9641617 ↗
  • MalfunctionJan 29, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK DEVICE VALVE IS TURNED OFF TO THE PATIENT AND IT HAS BEEN FLUSHED, BLOOD IS STILL GETTING INTO THE SHEATH. THE PHYSICIAN IS CONCERNED CLOT BUILDS UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED 08JANUARY2019: THE CASE PERFORMED WAS A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE PROCEDURE OUTCOME WAS SUCCESSFUL, THIS ISSUE DID NOT LEAD TO BLOOD LOSS. THE PATIENT WAS STABLE AND THE CASE WAS COMPLETED WITH THE SAME SHEATH.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9641616 ↗
  • MalfunctionJan 29, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK DEVICE VALVE IS TURNED OFF TO THE PATIENT AND IT HAS BEEN FLUSHED, BLOOD IS STILL GETTING INTO THE SHEATH. THE PHYSICIAN IS CONCERNED CLOT BUILDS UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED 08JANUARY2019: THE CASE PERFORMED WAS A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE PROCEDURE OUTCOME WAS SUCCESSFUL, THIS ISSUE DID NOT LEAD TO BLOOD LOSS. THE PATIENT WAS STABLE AND THE CASE WAS COMPLETED WITH THE SAME SHEATH.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9641614 ↗
  • MalfunctionJan 28, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK VALVE WAS TURNED OFF TO THE PATIENT, AND HAD BEEN FLUSHED, BLOOD WAS STILL GETTING INTO THE SHEATH. THE PHYSICIAN WAS CONCERNED THAT CLOTS BUILD UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING THE CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED ON 08JAN2020. THE CASE WAS REPORTED TO BE EITHER A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE CASE WAS SUCCESSFUL AND WAS COMPLETED WITH THE SAME SHEATH. THE EVENT DID NOT LEAD TO BLOOD LOSS, THE PATIENT WAS IN STABLE CONDITION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9637253 ↗
  • MalfunctionJan 28, 2020Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT WHEN THE IK VALVE WAS TURNED OFF TO THE PATIENT, AND HAD BEEN FLUSHED, BLOOD WAS STILL GETTING INTO THE SHEATH. THE PHYSICIAN WAS CONCERNED THAT CLOTS BUILD UP IN THE SHEATH AND THEN WHEN HE ADVANCES THE CATHETER, HE IS PUSHING THE CLOT UP THE AORTA WITH THE CATHETER. ADDITIONAL INFORMATION WAS RECEIVED ON 08JAN2020. THE CASE WAS REPORTED TO BE EITHER A HEART CATHETERIZATION OR A PERIPHERAL LEG CASE. THE CASE WAS SUCCESSFUL AND WAS COMPLETED WITH THE SAME SHEATH. THE EVENT DID NOT LEAD TO BLOOD LOSS, THE PATIENT WAS IN STABLE CONDITION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9637248 ↗
  • MalfunctionJan 7, 2020Material Deformation; Material Deformation

    THE USER FACILITY REPORTED THAT THE INVOLVED IK DEVICE WAS USED AND WHILE FLUSHING THE SHEATH PRIOR TO INSERTING INTO PATIENT, IT WAS NOTICED TO BE KINKED IN THE MIDDLE OF THE SHAFT. ANOTHER IDENTICAL SHEATH WAS OPENED AND USED TO COMPLETE THE PROCEDURE. THE PATIENT'S CONDITION WAS STABLE, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. THE PROCEDURE WAS A LEFT HEART CATHETERIZATION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9559821 ↗
  • MalfunctionDec 12, 2019Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT IK DEVICE VALVE WAS LEAKING.

    Patient problems: No Information

    MAUDE report 9458393 ↗
  • MalfunctionDec 12, 2019Leak/Splash; Leak/Splash

    THE USER FACILITY REPORTED THAT THE IK DEVICE VALVE WAS LEAKING.

    Patient problems: No Information

    MAUDE report 9458370 ↗
  • MalfunctionOct 29, 2019Material Deformation; Material Deformation

    THE USER FACILITY REPORTED THAT THERE WAS A CRIMPED AREA NOTED ON THE SHAFT OF THE IK SHEATH. THIS WAS DISCOVERED PRIOR TO USING OR ATTEMPTING TO USE THE DEVICE. A NEW SHEATH WAS USED TO COMPLETE THE CASE. THERE WAS NO PATIENT INJURY. THE PROCEDURE OUTCOME WAS SUCCESSFUL. ADDITIONAL INFORMATION WAS RECEIVED ON 10OCT2019. THE PROCEDURE WAS A HEART CATHETERIZATION / PERCUTANEOUS CORONARY INTERVENTION (PCI). THE PATIENT WAS IN STABLE CONDITION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9251765 ↗
  • MalfunctionJun 10, 2019Detachment of Device or Device Component; Detachment of Device or Device Component

    ADDITIONAL INFORMATION WAS RECEIVED ON JUNE 28, 2019. THE TYPE OF PROCEDURE WAS A CARDIAC CASE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8683434 ↗

Other INTRODUCER, CATHETER devices

All INTRODUCER, CATHETER devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.