PINNACLE RSB703Recalls & reported problems

Terumo Medical Corporation · PINNACLE R/O II Introducer Sheath with Radiopaque Marker · Class 2

All models of PINNACLE (35)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00389701007601), received between Nov 21, 2025 and Nov 21, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Separation Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Separation Problem1

Patient problems

  • Foreign Body Embolism1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 21, 2025Separation Problem; Separation Problem

    TERUMO MEDICAL CORPORATION RECEIVED THE FOLLOWING REPORTED INFORMATION: THE PATIENT WAS SCHEDULED TO HAVE AN ABLATION PROCEDURE, A 7FR TERUMO SHEATH WAS INSERTED IN RIGHT FEMORAL VEIN HOWEVER ON REMOVAL FOR A STANDARD EXCHANGE OF THE SHEATH IT FRACTURED IN THE PATIENT. THE LARGE PORTION OF SHEATH THAT WAS FRACTURED IN THE PATIENT WAS LATER REMOVED THAT DAY BY THE DOCTOR FROM VASCULAR SURGERY, THE SHEATH WAS PLACED IN A STERILE CUP. THE ESTIMATED BLOOD LOSS WAS LESS THAN 250CC. ADDITIONAL INFORMATION WAS RECEIVED ON 12NOV2025: THERE WAS TORTUOSITY EXPERIENCED WHEN THE SHEATH BREAK OCCURRED DURING REMOVAL. THE PATIENT WAS NOT IN SPASM WHEN THE BREAK OCCURRED. THERE WAS SOME RESISTANCE EXPERIENCED DURING SHEATH REMOVAL FROM THE PATIENT. THE INTENDED ABLATION PROCEDURE WAS ABLE TO BE COMPLETED FOR THE PATIENT ON (B)(6) 2025. THE PATIENT CONDITION WAS STABLE, HOWEVER TRANSFERRED TO THE INTENSIVE CARE UNIT (ICU) AND THEN TO THE OPERATING ROOM (OR) TO VASCULAR SURGERY FOR A CUT DOWN PROCEDURE TO RETRIEVE RETAINED PORTION OF THE SHEATH.

    Patient problems: Foreign Body Embolism

    MAUDE report 23619709 ↗