Stealth® Clamps A3203Recalls & reported problems

Applied Medical Resources Corporation · Vascular Clamp, Reusable · Class 2

All models of Stealth Clamps (7)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
16
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 00607915112721), received between Mar 30, 2017 and Mar 2, 2026 — classified as 16 malfunctions.

The most frequently reported specific device problem is “Difficult to Open or Close” (10 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Open or Close10
  • Migration or Expulsion of Device4
  • Patient Device Interaction Problem2
  • Failure to Align1

Patient problems

  • No Known Impact Or Consequence To Patient14
  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 2, 2026Patient Device Interaction Problem

    NAME OF PROCEDURE BEING PERFORMED: UROLOGIC PROCEDURE ON THE SPERMATIC CORD. EVENT DESCRIPTION: PARALLEL CLAMPING NO LONGER POSSIBLE DUE TO FREQUENT USE. IT'S A SERVICE REQUEST: ORIGINAL CONDITIONS PROBABLY NOT REPAIRABLE. PLEASE PROVIDE A FREE REPLACEMENT. PRODUCT IS ALREADY IN AME. OR NURSE SENDS THE A3203 CLAMP TO STERILIZATION. ROUTINE FUNCTIONALITY CHECK ACCORDING TO THEIR STANDARDS: STERILIZATION SENDS IT TO US WITH A SERVICE REQUEST. NO PATIENTS AFFECTED. INTERVENTION: THEY USE THEIR SECOND CLAMP. PATIENT STATUS: NA.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24488181 ↗
  • MalfunctionAug 19, 2025Failure to Align; Patient Device Interaction Problem; Failure to Align; Patient Device Interaction Problem

    PROCEDURE PERFORMED: UROLOGICAL PROCEDURE ON THE SPERMATIC CORD. EVENT DESCRIPTION: THE STEALTH CLAMP WAS USED REGULARLY FOR A UROLOGICAL PROCEDURE ON THE SPERMATIC CORD. REASON: TEAR DUE TO FREQUENT USE. PARALLEL CLAMPING NO LONGER POSSIBLE DUE TO FREQUENT USE. ADDITIONAL INFORMATION RECEIVED BY APPLIED MEDICAL REP VIA EMAIL ON 11AUG25: THE SURGEON DESCRIBES IT COLLOQUIALLY AS LOOKING LIKE ¿FINGER CROSSING¿ OF THE JAWS. IT WAS NOTICED BEFORE USE. PATIENT STATUS: NO CLINICAL IMPACT TO THE PATIENT. INTERVENTION: USER USED HIS SECOND A3203 STEALTH CLAMP.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22841566 ↗
  • MalfunctionApr 22, 2017Difficult to Open or Close; Difficult to Open or Close

    THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW, IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION . PROCEDURE PERFORMED: UNK TYPE OF INTERVENTION: UNK PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6513676 ↗
  • MalfunctionApr 22, 2017Difficult to Open or Close; Difficult to Open or Close

    THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2 017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION. PROCEDURE PERFORMED: UNK. TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6513673 ↗
  • MalfunctionApr 22, 2017Migration or Expulsion of Device; Migration or Expulsion of Device

    PROCEDURE PERFORMED: NA. THE CUSTOMER WAS TESTING THEIR CLAMPS AND IDENTIFIED THAT AT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNLOCK. TYPE OF INTERVENTION: NA. PATIENT STATUS: NA.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6513667 ↗
  • MalfunctionApr 22, 2017Migration or Expulsion of Device; Migration or Expulsion of Device

    PROCEDURE PERFORMED: NA. THE CUSTOMER WAS TESTING THEIR CLAMPS AND IDENTIFIED THAT AT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNLOCK. TYPE OF INTERVENTION: NA. PATIENT STATUS: NA.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6513665 ↗
  • MalfunctionApr 22, 2017Migration or Expulsion of Device; Migration or Expulsion of Device

    PROCEDURE PERFORMED: NA. THE CUSTOMER WAS TESTING THEIR CLAMPS AND IDENTIFIED THAT AT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNLOCK. TYPE OF INTERVENTION: NA. PATIENT STATUS: NA.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6513664 ↗
  • MalfunctionApr 22, 2017Migration or Expulsion of Device; Migration or Expulsion of Device

    PROCEDURE PERFORMED: NA. THE CUSTOMER WAS TESTING THEIR CLAMPS AND IDENTIFIED THAT AT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNLOCK. TYPE OF INTERVENTION: NA. PATIENT STATUS: NA.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6513663 ↗
  • MalfunctionApr 7, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED: UNKNOWN - THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION. TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6474311 ↗
  • MalfunctionApr 7, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED: UNKNOWN - THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6474310 ↗
  • MalfunctionApr 5, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED: UNKNOWN - THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION. ADDITIONAL CERS CREATED 2017-0423, 2017-0463, 2017-0464, 2017-0465, 2017-0466, 2017-0467, 2017-0468, 2017-0469, 2017-0470, 2017-0471, 2017-0472, 2017-0473, 2017-0474. TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6462520 ↗
  • MalfunctionApr 5, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED: UNKNOWN - THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION (B)(4). TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6462501 ↗
  • MalfunctionApr 5, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED: UNKNOWN - THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION ADDITIONAL CERS CREATED (B)(4). TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6462428 ↗
  • MalfunctionApr 5, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED: UNKNOWN - THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION. (B)(4). TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6462411 ↗
  • MalfunctionApr 5, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED: UNKNOWN - THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION. ADDITIONAL CERS CREATED (B)(4). TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6462355 ↗
  • MalfunctionMar 30, 2017Difficult to Open or Close; Difficult to Open or Close

    PROCEDURE PERFORMED UNKNOWN. THE DOCTOR MENTIONED TO THE INSTRUMENT SPECIALIST THAT WHEN THE INSERT IS ATTACHED TO THE JAW IT IS DIFFICULT FOR THE CLAMP TO MAINTAIN CLAPPED IN THE LOCKED POSITION. THE DOCTOR USED THE A0C02 INSERTS. APPLIED MEDICAL RECEIVED ADDITIONAL INFORMATION ON MARCH 14,2017 FROM THE CUSTOMER VIA PHONE: THE CUSTOMER HAS CONFIRMED THAT WHEN THE JAW IS CLAMPED CLOSED IT WOULD EASILY UNCLASP. IF THE HANDLE WERE TO BE TAPPED THE CLAMP WOULD RELEASE. PREVAC STEAM WAS USED TO STERILIZATION TYPE OF INTERVENTION: UNK. PATIENT STATUS: THE CALLER WAS NOT INFORMED OF ANY PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6446726 ↗

FDA clearance and classification

The FDA regulates product code DXC (clamp, vascular) under 21 CFR 870.4450 as a Class II device. 21 CFR 870.4450 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Stealth® Clamps A3203

Has the Stealth® Clamps A3203 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00607915112721), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Stealth® Clamps A3203?

The FDA's MAUDE database lists 16 adverse event reports for this device, received between Mar 30, 2017 and Mar 2, 2026. In those reports, the most common specific device problems are “Difficult to Open or Close” (10), “Migration or Expulsion of Device” (4) and “Patient Device Interaction Problem” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Stealth® Clamps A3203?

None of the reports are classified as deaths, 0 as injuries and 16 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the Stealth® Clamps A3203, and is it still sold?

The FDA's device database lists Applied Medical Resources Corporation as the company responsible for it (brand Stealth® Clamps, model A3203). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Clamp, Vascular devices

All Clamp, Vascular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page